I want to search for...
Permit #2006020245
Permit Details
Status: COED
| CONDITIONED SPACE: 2574 sqft |
| GARAGE: 477 sqft |
| OPENED PORCH (WITH ROOF) : 374 sqft |
| OPENED PORCH (WITH ROOF) : 27 sqft |
| Total Square Footage: 3452 sqft |
| Subdivision: 2070 - Grand Haven North Phase 1 @ Grand Haven |
| Job Phone: (386) 445-4515 |
| Location Address: 11 WATERVIEW DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/27/2006 |
| NOC: RECORDED |
| Applicant name: GREGORY LEE LE PERA |
| Owner: PHILLIP TURNER JR |
|
Address LINDA D TURNER AUBURN HILLS, MI 48326 |
|
Address 864 HUNT CLUB BLVD AUBURN HILLS, MI 48326 |
| Lot: 85 |
| Contracted Stated Job Value: ¤163,240.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
WAYNE HOMES BY CENTEX
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
385 DOUGLAS AVE ALTAMONTE SPRINGS, FL 32714 |
STE 3000 ALTAMONTE SPRINGS, FL 32714 |
CBC055301 (Exp: 09/30/2008) | (386) 445-4515 | (386)446-6285 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
EDWARD DOUGLAS TENNANT
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
3370 AGRICULTURAL CENTER DRIVE ST. AUGUSTINE , FL 32092 |
CAC1813372 (Exp: 08/31/2026) | (904)829-8898 | (904)829-6587 |
GARY WAYNE EVERS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 740106 ORANGE CITY, FL 32763 |
CFC050566 (Exp: 08/31/2026) | 386-775-0909 | 386-775-0918 |
GREGORY A HAGEMAN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
545 Parque Drive Ormond Beach, FL 32174 |
CCC021394 (Exp: 08/31/2026) | (386) 672-2821 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 08/10/2006 | FINAL APPROVED | KSAMPICO |
| STORMWATER FINAL INSPECTION | 08/08/2006 | APPROVED | DRANDALL |
| UTILITY COMPANY FINAL | 08/02/2006 | APPROVED | TSCHWEERS |
| RESIDENTIAL EARLY POWER | 06/26/2006 | APPROVED | JMCGOWEN |
| LATH /BRICK FLASHING | 05/26/2006 | APPROVED | JMCGOWEN |
| INSULATION INSPECTION | 05/19/2006 | APPROVED | CMINI |
| ALL ROUGH | 05/16/2006 | APPROVED | JMCGOWEN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/02/2006 | APPROVED - AS NOTED | CMINI |
| Note: FILL NAIL HOLES BACK PORCH HANGER ON RIGHT. | |||
| LINTEL | 04/11/2006 | APPROVED | JMCGOWEN |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 04/10/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 03/30/2006 | APPROVED | JMCGOWEN |
| FIRST ROUGH PLUMBING INSPECTION | 03/27/2006 | APPROVED | JMCGOWEN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/17/2006 | 04/18/2006 |
| Note: Released By: LWOODROME Revision: Truss connectors | |||
| BLD | COMPLETE | 02/23/2006 | 02/24/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R. | |||
| URB | COMPLETE | 02/23/2006 | 02/23/2006 |
| Note: Released By: CGOEWEY 2/23/06 (CB) REMOVE "K", TOO CLOSE TO HOUSE. | |||
| ZON | COMPLETE | 02/21/2006 | 02/23/2006 |
| Note: Released By: HHERKERT | |||
| SW1 | COMPLETE | 02/07/2006 | 02/22/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | HOLD | 02/07/2006 | 02/16/2006 |
| Note: Held By: HHERKERT square foot tabulation is incorrect | |||
| BLD | HOLD | 02/20/2006 | |
| Note: Held By: FREODICA 1. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 2. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 3. Indicate how attic access will be constructed to comply with FRC Section R309.2. 4. Provide bond beam transition detail. 5. The roof loading indicated on sheet 6 does not meet code requirements for general attic space of 10psf live load per FRC Table R301.5. The top chord loading meets the code requirements of Table R301.6 however the bottom chord does not meet the live load requirement of Table R301.5. Please revise the roof loading information on sheet 6 to indicate 10psf bottom chord live load or provide a footnote to the loading table stating that a non-concurrent application of 10lbs bottom chord live load shall be applied to the entire chord. CITY OF PALM COAST o 2 COMMERCE BLVD o PALM COAST, FL 32164 PHONE: 386-986-3780 o FAX: 386-986-3781 *The City is also requesting that there is a 6" x 6" area on the cover page (first drawing sheet) for City comments and approval stamp. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 08/10/2006 |
| REVISION | ¤40.00 | 08/10/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 02/27/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 02/27/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 02/27/2006 |
| ADMIN FEE | ¤20.00 | 02/27/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 02/27/2006 |
| BUILDING CODE ADMIN FUND | ¤17.26 | 02/27/2006 |
| ELECTRIC FEE | ¤179.40 | 02/27/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 02/27/2006 |
| MECHANICAL FEE | ¤179.40 | 02/27/2006 |
| PERMIT FEE | ¤971.10 | 02/27/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 02/27/2006 |
| PLAN CHECK FEE | ¤99.60 | 02/27/2006 |
| PLUMBING FEE | ¤179.40 | 02/27/2006 |
| RADON FEE | ¤17.26 | 02/27/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,091.31 |