I want to search for...

Permit #2007070059

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7030-00490-0180
CONDITIONED SPACE: 978 sqft
Total Square Footage: 978 sqft
Block: 00490
Subdivision: -
Job Phone: (386) 445-5239
Location Address: 21 RALPH PL
Type: BA - BUILDING ADDITION
Issue Date: 07/11/2007
NOC: RECORDED
Applicant name: KEITH M PARKER
Owner: KEGLEY, ROBERT A & ADELET H

Address

21 RALPH PL

PALM COAST, FL 32135

Lot: 0180
Contracted Stated Job Value: ¤40,000.00
Job Description: ADDITION
Type: CN

Contractor

DILLARD CONSTRUCTION LLC.
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 355007

PALM COAST, FL 32137

CGC1510399 (Exp: 09/30/2010) 386-864-1320 (386)986-3054

Sub Contractors

ROBERT G DELLO RUSSO
Status Location Address State License Number Phone Fax
DECEASED

531 CODISCO WAY

SANFORD, FL 32771

CAC032448 (Exp: 08/31/2022) (407)831-2665 (407)333-3853
MARTIN JOHN EVANS
Status Location Address State License Number
ACTIVE

14 FORT CAROLINE CT

BUNNELL, FL 32110

CFC057676 (Exp: 08/31/2026)
MARION KEITH MILNE JR
Status Location Address State License Number Phone Fax
ACTIVE

134 HOLLAND ROAD

ORMOND BEACH, FL 32176

CCC1326073 (Exp: 08/31/2026) (386)986-8688 (386) 492-2657
JOHN S SMITH
Status Location Address State License Number
CANCEL

P. O. BOX 1160

Bunnell, FL 32110

ER0007785 (Exp: 08/31/2015)

Inspection History

Type Request Date Result Inspector
ELECTRICAL FINAL 06/09/2008 FINAL APPROVED LHITES
FINAL INSPECTION (MISC) 06/09/2008 FINAL APPROVED LHITES
Note: THIS IS A REINSPECTION
FINAL INSPECTION (MISC) 06/05/2008 Disapproved -FEE REQUIRED MMOORE
Note: THIS IS A REINSPECTION...1. Scuttle hole is too small for the removal of mechanical equipment (hot water heater), from attic 2. Existing electrical panel has been rewired from aluminum to copper in garage and has not been inspected.
PROJECT STATUS INSPECTION 06/03/2008 Disapproved - NO FEE DROCKWELL
Note: Trusses in question appear to be in accordence to code.They are plumb within tolorance and braced to plan.Workmanship and choice of materials(plywood) are in question.Plyood bows between trusses in numberous areas plywood clips are compromised where dips appear
FINAL INSPECTION (MISC) 04/01/2008 Disapproved -FEE REQUIRED JGIBSON
Note: NEED REVISION TO SHOW FUTURE POOL CONNECTION AND GENERATOR, ALSO NEED REVISION TO SHOW WATER HEATER IN ATTIC ABOVE AND SEAL OFF A/H CLOSET [ JOINTS NOT MADE UP].........MARK 931-2912
STORMWATER FINAL INSPECTION 03/28/2008 APPROVED - AS NOTED GLALIMA
Note: placing sod at time of inspection
UTILITY COMPANY FINAL 03/28/2008 APPROVED MBACON
INSULATION INSPECTION 01/09/2008 APPROVED MMOORE
ALL ROUGH 01/04/2008 APPROVED - AS NOTED DROCKWELL
Note: THIS IS A REINSPECTION PROTECT PAN OVERFLOW LINE AT FIREBLOCK WITH NAIL GUARD/PROTECT NM CABLE AT TOP PLATE IN BEDROOM AT A/C REGISTAR WITH NAIL GUARD
ALL ROUGH 12/26/2007 Disapproved -FEE REQUIRED MMOORE
Note: 1. OUTLET BOX (METAL) ABOVE TRUSSES NOT FINISHED 2. FRAME ATTIC ACCESS FOR HOT WATER HEATER 3. WIRING ABOVE ELECTRIC PANEL TO BE ATTACHED 12" TO A WOOD BLOCK BETWEEN STUDS 4. METAL ELECTRIC PANEL COVER ABOVE TRUSSES.... WHAT FOR?
ALL ROUGH 12/21/2007 CANCELLED BY APPLICANT JGIBSON
Note: requested by delmira CONTRACTOR CALLED AND CANCELED INSPECTION @ 10:20 AM
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 11/05/2007 APPROVED - AS NOTED ACOOPER
Note: ADD STRAPS FRONT AND REAR TO THE TRUSS NEXT TO THE EXISTING HOME.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 11/02/2007 Disapproved -FEE REQUIRED ACOOPER
Note: ROOF DRIP EDGE TO BE ON FOR THIS INSPECTION, AT REAR DOOR;EACH SIDE IS TO BE ANCHORED WITHIN 12" OF END OF WALL, ADD STRAP ON TRUSS THAT IS CLOSEST TO THE HOUSE AT THE ENDS, ADD BRACE TO GABLE TRUSS PER NOTE "A", ADD STRAPS AND CLIPS TO GIVE A CONTINUOUS LOAD PATH AT REAR SLIDER (BOTH SIDES).
LINTEL 08/28/2007 APPROVED ACOOPER
MONOLITHIC SLAB INSPECTION/SLAB 08/01/2007 APPROVED JHINDMAN
FIRST ROUGH PLUMBING INSPECTION 07/16/2007 APPROVED JHINDMAN

Review History

Department Status Date In Date Out
BLD COMPLETE 06/11/2008 06/12/2008
Note: Released By: FREODICA Truss engineer letter re. attaching 2x4 between top chord of trusses.
BLD COMPLETE 05/19/2008 05/20/2008
Note: Released By: JMCGOWEN
BLD HOLD 04/02/2008 04/02/2008
Note: Held By: JJOSEPH 1.Provide details indicating how the water heater will be supported at the attic access.? (Trusses and connectors) 2. Documentation shows existing service is 150A for this home. Provide documentation to show that the existing service will support the additional equipment loads, ie: 2nd AHU, 2nd CU/heat pump, 2nd Hot Water Heater.
SW1 COMPLETE 07/05/2007 07/06/2007
Note: Released By: WKINELL
ZON COMPLETE 07/03/2007 07/05/2007
Note: Released By: ECOYNE
BLD COMPLETE 07/10/2007
Note: Released By: LWOODROME approved for release as noted on plan cover sheet. Checked by Auba
BLD HOLD 07/06/2007
Note: Held By: JJOSEPH Please clarify If the existing master bedroom will be a bedroom or a part of the living room.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 06/10/2008
REVISION ¤80.00 06/04/2008
REINSPECTION FEE ¤40.00 06/04/2008
ADDITIONAL FEE ¤40.00 06/04/2008
REINSPECTION FEE ¤40.00 03/31/2008
ADDITIONAL FEE ¤40.00 03/31/2008
REINSPECTION FEE ¤40.00 03/31/2008
STORM WATER PERMIT FEES ¤80.00 07/11/2007
ADMIN FEE ¤20.00 07/11/2007
ARC RESIDENTIAL ALTERATION ¤50.00 07/11/2007
BUILDING CODE ADMIN FUND ¤4.89 07/11/2007
ELECTRIC FEE ¤79.80 07/11/2007
MECHANICAL FEE ¤79.80 07/11/2007
PERMIT FEE ¤498.00 07/11/2007
PLAN CHECK FEE ¤40.00 07/11/2007
PLUMBING FEE ¤79.80 07/11/2007
RADON FEE ¤4.89 07/11/2007
Fees Total Due: ¤0.00 Total Paid: ¤1,257.18