I want to search for...
Permit #2020061198
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7013-00140-0350 |
| Total Square Footage: 2603 sqft |
| Block: 00140 |
| Subdivision: 2192 - SECTION 13-BELLE TERRE |
| Job Phone: 904-282-5050 |
| Location Address: 78 BRITTANY LN |
| Type: ME - MECHANICAL |
| Issue Date: 06/24/2020 |
| NOC: Unknown |
| Applicant name: MICHAEL R NIQUETTE |
| Owner: BENJAMIN MARK A & ELIZABETH BENJAMIN H&W |
|
Address 78 BRITTANY LANE PALM COAST, FL 32137 |
| Lot: 0350 |
| Contracted Stated Job Value: ¤2,000.00 |
| Job Description: REPLACE 3.5 TON, 14 SEER HP SYSTEM EQUAL CHANGE OUT |
| Type: CN |
Contractor
TOTAL AIR CARE INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 2004 ORANGE PARK, FL 32065 |
CAC1815232 (Exp: 08/31/2022) | 904-282-5050 | 904-291-5956 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 07/20/2020 | FINAL APPROVED | CPISCITELLI |
| Note: PLEASE CALL MRS. BENJAMIN- (904) 679-2378 | |||
| HVAC FINAL | 07/06/2020 | Disapproved -FEE REQUIRED | CPISCITELLI |
| Note: 1. ODU calls for Max 45 AMP. There is a 50 AMP in panel. 2. AHU heater not marked. Hand written says 5KW. There is a 60 AMP in panel. Could not verify breaker in panel. 3. Hole around lines going into base needs to be sealed. 4. ODU sitting on plastic pad. Provide florida product approval for pad or remove and anchor to a hurricane rated pad. |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 06/24/2020 | 06/24/2020 |
| Note: Released By: CPISCITELLI |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 07/17/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 06/24/2020 |
| SURCHARGE - FS 468.631 | ¤2.00 | 06/24/2020 |
| ADMIN FEE | ¤20.00 | 06/24/2020 |
| INSPECTION 40 | ¤40.00 | 06/24/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤104.00 |