I want to search for...
Permit #2021020339
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7002-00010-0190 |
| Block: 00010 |
| Subdivision: 2218 - SECTION 2-FLORIDA PARK |
| Job Phone: 386-237-8637 |
| Location Address: 37 FARRADAY LN |
| Type: DR - DRIVEWAY |
| Issue Date: 02/12/2021 |
| NOC: RECORDED |
| Applicant name: ERIC GLENN SAMUELSON |
| Owner: WILLIAMS, BRIAN |
|
Address 37 FARRADAY LANE PALM COAST, FL 32137 |
| Lot: 0190 |
| Contracted Stated Job Value: ¤17,200.00 |
| Job Description: DRIVEWAY MODIFICATION |
| Type: CN |
Contractor
OUTBACK MARINE CONSTRUCTION
| Status | Location Address | State License Number | Phone |
| ACTIVE |
597 JOHN ANDERSON HWY FLAGLER BEACH, FL 32181 |
CBC1257381 (Exp: 08/31/2026) | 386-237-8637 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 08/05/2021 | FINAL APPROVED | DHANEY |
| ROW- PAVER RESTRAINTS | 08/02/2021 | APPROVED | KRUTH |
| Note: THIS IS A REINSPECTION | |||
| ROW - FINAL APRON (AFTER POUR) | 08/02/2021 | APPROVED | KRUTH |
| ROW - FINAL INSPECTION | 08/02/2021 | APPROVED | KRUTH |
| ROW- PRE-APRON (PRE-POUR) | 06/28/2021 | APPROVED - AS NOTED | KRUTH |
| Note: pipe is good at the time of the inspection It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete. | |||
| ROW- PAVER RESTRAINTS | 06/28/2021 | PARTIALLY APPROVED | KRUTH |
| MONOLITHIC SLAB | 03/17/2021 | APPROVED | BGREVE |
| Note: THIS IS A REINSPECTION new to existing conrete floor typical tie in detail calls for #5 bars at 32"'s on center with 6"embedment. bars not spaced per detail and two bars pulled out of existing footing/concrete floor | |||
| MONOLITHIC SLAB | 03/15/2021 | Disapproved - NO FEE | BGREVE |
| Note: new to existing conrete floor typical tie in detail calls for #5 bars at 32"'s on center with 6"embedment. bars not spaced per detail and two bars pulled out of existing footing/concrete floor |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 02/04/2021 | 02/11/2021 |
| Note: Released By: TBAKER | |||
| UTL | COMPLETE | 02/04/2021 | 02/10/2021 |
| Note: Released By: LFITZGERALD | |||
| ZON | COMPLETE | 02/04/2021 | 02/05/2021 |
| Note: Released By: TDOAK | |||
| BLD | COMPLETE | 02/04/2021 | 02/11/2021 |
| Note: Released By: FREODICA |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN FEE | ¤20.00 | 02/12/2021 |
| BUILDING DISCOUNT 100% | (¤20.00) | 02/12/2021 |
| RECORDING FEE REIMBURSE DOC | ¤44.00 | 02/12/2021 |
| SITE PLAN 20 | ¤20.00 | 02/12/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 02/12/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 02/12/2021 |
| STORM WATER PERMIT FEES | ¤40.00 | 02/12/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤108.00 |