I want to search for...
Permit #2023111128
Permit Details
Status: EXPIRED
| Parcel Id: 07-11-31-7034-01220-0100 |
| Block: 01220 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: 386-931-6532 |
| Location Address: 21 EDMOND PL |
| Type: DR - DRIVEWAY |
| Issue Date: 12/18/2023 |
| NOC: RECORDED |
| Applicant name: JOSE LOPEZ |
| Owner: PINKSTON BRIAN K & IVY KAY H&W |
|
Address 21 EDMUND PLACE PALM COAST, FL 32164 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤8,000.00 |
| Job Description: CONCRETE CIRCULAR DRIVEWAY |
| Type: CN |
Contractor
JOSE LOPEZ CONSTRUCTION, INC.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
14 UTILITY DRIVE #12 BUNNELL, FL 32110 |
CRC1327719 (Exp: 08/31/2026) | (386)445-9424 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 05/09/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: *** NOTES ADDED BY FSLADISH 5/9/2024 11:44:05 AM *** 5/9/24 PIPE ELEVATION GOOD. CUTS MADE. CULVERT CLEAR. YOU WILL BE REQUIRED TO LAY A 12" X 12" HOT PATCH AT THE FRONT OF THE DRIVEWAY APRON PER COPC SPECIFICATIONS IN SECTION 500 OF THE COPC ENGINEERING STANDARDS SECTION TECHNICAL MANUAL. Inspector Notes from Inspection 9270 1/2/24 READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. | |||
| ROW - FINAL INSPECTION | 05/09/2024 | Disapproved - NO FEE | FSLADISH |
| Note: *** NOTES ADDED BY FSLADISH 5/9/2024 11:47:32 AM *** 5/9/24 YOU ARE REQUIRED BY COPC ENGINEERING STANDARDS SECTION 500 DRIVEWAY DETAIL TO LAY A 12" X 12" HOT PATCH ABUTTING THE DRIVEWAY APRON POUR AT ROAD EDGE. PLEASE MAKE CORRECTION BEFORE RESUBMITTING FOR FINAL INSPECTION. Inspector Notes from Inspection 9270 1/2/24 READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. | |||
| U -UTILITY RESIDENTIAL FINAL | 05/09/2024 | FINAL APPROVED | JHARDING |
| ROW- PRE-APRON (PRE-POUR) | 01/02/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 1/2/24 READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. | |||
| ROW - FINAL INSPECTION | |||
| Note: 5/9/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY FSLADISH 5/9/2024 11:47:32 AM *** 5/9/24 YOU ARE REQUIRED BY COPC ENGINEERING STANDARDS SECTION 500 DRIVEWAY DETAIL TO LAY A 12" X 12" HOT PATCH ABUTTING THE DRIVEWAY APRON POUR AT ROAD EDGE. PLEASE MAKE CORRECTION BEFORE RESUBMITTING FOR FINAL INSPECTION. Inspector Notes from Inspection 9270 1/2/24 READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 11/29/2023 | 12/01/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| UTL | COMPLETE | 11/29/2023 | 12/08/2023 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/29/2023 | 11/29/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤15.00) | 12/18/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/18/2023 |
| SW ENG INSPECTION 40 | ¤40.00 | 12/18/2023 |
| SW ENG PRE APRON | ¤30.00 | 12/18/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 12/18/2023 |
| SITE PLAN 15 | ¤15.00 | 12/18/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤300.00 |