I want to search for...
Permit #2024060322
Permit Details
Status: COED
| Parcel Id: 21-10-30-0000-02020-0010 |
| COMMERCIAL SQUARE FOOTAGE: 2500 sqft |
| Total Square Footage: 2500 sqft |
| Block: 02020 |
| Subdivision: - |
| Job Phone: 386-795-3234 |
| Location Address: 11100 US HWY 1 N |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 02/11/2025 |
| NOC: RECORDED |
| Applicant name: CHARLES ANDREW COLEMAN |
| Owner: HORIZON REAL ESTATE FUND LP |
|
Address 220 RIVERSIDE BLVD NEW YORK, NY 10069 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤176,031.00 |
| Job Description: Building 2 - Self Storage |
| Type: CN |
Contractor
COLEMAN GOODEMOTE CONSTRUCTION COMPANY INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
619 N. BEACH ST. DAYTONA BEACH, FL 32114 |
CGC057396 (Exp: 08/31/2026) | 386-257-3570 | 386-253-6692 |
Sub Contractors
SHAUN HAFFNER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
70 N PERROTT DR ORMOND BEACH, FL 32174 |
EC13010602 (Exp: 08/31/2026) | 386-333-9781 | 386-265-1989 |
Inspection History
| Type | Request Date | Result | Inspector |
| EXTERIOR ARCHITECTURAL FEATURES | 10/27/2025 | APPROVED | DRODRIGUEZ |
| U - UTILITY COMMERCIAL FINAL | 10/27/2025 | FINAL APPROVED | BWRIGHT |
| Note: 9/23/2025 - PREVIOUS INSPECTION NOTES | |||
| U - UTILITY COMMERCIAL FINAL | 09/23/2025 | CANCELLED BY APPLICANT | BWRIGHT |
| BUILDING FINAL | 09/23/2025 | APPROVED | FWILLIS |
| FIRE FINAL | 09/23/2025 | APPROVED | RMARTIN |
| ELECTRIC - EARLY POWER | 09/23/2025 | APPROVED | RMARTIN |
| LINTEL | 09/11/2025 | CANCELLED BY INSPECTOR | FWILLIS |
| FRAMING | 09/11/2025 | APPROVED | FWILLIS |
| Note: 6/11/2025 - PREVIOUS INSPECTION NOTES 6/10/2025 - PREVIOUS INSPECTION NOTES 6/5/2025 - PREVIOUS INSPECTION NOTES 6/4/2025 - PREVIOUS INSPECTION NOTES BUILDING #2 | |||
| ROOF SHEATHING / BRACE / TIE DOWN | 09/11/2025 | APPROVED | FWILLIS |
| Note: 8/11/2025 - PREVIOUS INSPECTION NOTES | |||
| ELECTRIC FINAL | 08/15/2025 | APPROVED | MKRASKI |
| ROOF SHEATHING / BRACE / TIE DOWN | 08/11/2025 | PARTIALLY APPROVED | FWILLIS |
| ELECTRIC 2ND ROUGH | 07/16/2025 | APPROVED | MKRASKI |
| FRAMING | 06/11/2025 | PARTIALLY APPROVED | FWILLIS |
| Note: 6/10/2025 - PREVIOUS INSPECTION NOTES 6/5/2025 - PREVIOUS INSPECTION NOTES 6/4/2025 - PREVIOUS INSPECTION NOTES BUILDING #2 | |||
| FRAMING | 06/10/2025 | PARTIALLY APPROVED | FWILLIS |
| Note: 6/5/2025 - PREVIOUS INSPECTION NOTES 6/4/2025 - PREVIOUS INSPECTION NOTES BUILDING #2 | |||
| INSULATION | 06/09/2025 | APPROVED | FWILLIS |
| Note: 6/5/2025 - PREVIOUS INSPECTION NOTES Building #2 6/4/2025 - PREVIOUS INSPECTION NOTES | |||
| INSULATION | 06/05/2025 | PARTIALLY APPROVED | FWILLIS |
| Note: Building #2 6/4/2025 - PREVIOUS INSPECTION NOTES | |||
| FRAMING | 06/05/2025 | PARTIALLY APPROVED | FWILLIS |
| Note: 6/4/2025 - PREVIOUS INSPECTION NOTES BUILDING #2 | |||
| INSULATION | 06/04/2025 | CANCELLED BY APPLICANT | FWILLIS |
| FRAMING | 06/04/2025 | PARTIALLY APPROVED | FWILLIS |
| Note: BUILDING #2 | |||
| FOUNDATION SURVEY - OFFICE USE ONLY | 04/25/2025 | APPROVED | DLEAP |
| ELECTRIC UNDERGROUND | 03/26/2025 | APPROVED | MKRASKI |
| MONOLITHIC SLAB | 03/26/2025 | APPROVED | FWILLIS |
| Note: BUILDING #2 | |||
| FOOTER | 03/26/2025 | APPROVED | FWILLIS |
| Note: BUILDING #2 |
Review History
| Department | Status | Date In | Date Out |
| PLENG | COMPLETE | 04/24/2025 | 04/25/2025 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM | |||
| PLENG | HOLD | 03/25/2025 | 03/25/2025 |
| Note: Held By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM 1. No Foundation elevation has been shown on the plans for building 2. | |||
| BLD | COMPLETE | 01/29/2025 | 02/10/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/29/2025 | 02/10/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| FI1 | COMPLETE | 01/29/2025 | 02/10/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| PLUM | CANCEL | 01/29/2025 | 02/10/2025 |
| ARCHR | COMPLETE | 01/29/2025 | 02/10/2025 |
| Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM | |||
| UD1 | COMPLETE | 01/29/2025 | 02/06/2025 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 01/29/2025 | 02/07/2025 |
| MECH | CANCEL | 01/29/2025 | 02/10/2025 |
| ARCHR | COMPLETE | 06/07/2024 | 06/24/2024 |
| Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/07/2024 | 06/25/2024 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-ACCESSIBILITY, FLORIDA STATUTES (F.S.), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). INCOMPLETE AND INCORRECT PLAN SUBMITTAL PROVIDED - BUILDING PLAN REVIEW NOT COMPLETED. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS MISSING AND / OR INCOMPLETE AND ARE REQUIRED SUBMITTAL DOCUMENTS PER SECTION 107 OF THE FLORIDA BUILDING CODE-BUILDING. . 1. Architectural plan sheets not signed and sealed with a verifiable digital signature except for plan cover sheet - not eligible for plan review. 2. Structural plan sheets not signed and sealed with a verifiable digital signature except for plan cover sheet - not eligible for plan review. 3. Plan sheets for all building types have been uploaded as a single set of co-mingled plan sheets. Plans must be separated for each building and provided with separate cover sheet and separate index of plan sheets. 4. Architectural and structural plan sheets to be uploaded as individual files - cannot be grouped and uploaded in a single set. 5. Structural plan sheets for all building types have been uploaded as a single set of co-mingled plan sheets. Plan sheets must be separated for each building and provided with separate cover sheet and separate index of plan sheets. 6. City of Palm Coast Product Approval Worksheet not provided. 7. Structural plan sheets all reference the incorrect Florida Building Codes and ASCE -7 and will not be reviewed or accepted for submittal until revied to comply with the current Florida Building Code and current referenced standards. | |||
| DSD | COMPLETE | 06/07/2024 | 06/24/2024 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 06/07/2024 | 06/24/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit electrical plans. | |||
| FI1 | HOLD | 06/07/2024 | 06/24/2024 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please provide a written response to each comment below in a response letter, provide clouded response changes on plan sheets and add page locations for each response. 1. Plans submitted online must be digitally signed and sealed for review. http://docs.palmcoastgov.com/departments/building/online/digital-signatures.pdf 2. There are several pages with the wrong code years, please insure code years are current on all plan pages. Please include the following code versions the plan sheets anywhere they appear on the plans… FBC 8th edition (2023) FFPC 8th edition (2023) Florida Fire Prevention Code with the Florida specific NFPA 1 and 101 NFPA 10, (2018) edition, Standard for Portable Fire Extinguishers NFPA 13, (2019) edition, Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies NFPA 72, (2019) edition, National Fire Alarm and Signaling Code NFPA 70, (2020) edition, National Electrical Code 3. Please provide Classification of hazard of occupancy per FFPC 101, 42.1.2 4. Please provide engineering basis of design for fire sprinkler systems and fire alarm systems as part of these submitted plans. A Florida licensed professional engineer is responsible to establish design concepts established through the Responsibility Rules adopted by the Florida Board of Professional Engineers. F.S. 633.102 (19). Layout of risers, cross mains, branch lines, sprinkler heads, sizing of pipe, hanger locations, and hydraulic calculations in accordance with the design concepts established by the engineer are provided by the licensed fire protection contractor under separate building permit for installation of fire sprinkler and fire alarm systems. 5. Please provide information on the Knox access box for rapid entry access of fire department into the building per NFPA 1, 18.2.2.1 and AHJ And place the following note on the cover sheet. Please select FLAGLER COUNTY DEPT. of EMERGENCY MANAGEMENT, for jurisdiction or agency even though it is going in the city. This way it will get it keyed correctly. https://www.knoxbox.com/Products/Commercial-KnoxBoxes And place the following note on the cover sheet: Please call Fire Marshal, Randy Holmes at: 386-986-2303 for proper placement and verification of proper placement for the Knox Box and placement of the Property access keys. 6. Provide Fire Extinguishers located so that the maximum travel distances does not exceed 75 ft. (including the exterior for the portions of the building with storage accessed only from the exterior) per FFPC 1, 13.6.3.2.1.2.2 | |||
| GAS | CANCEL | 06/07/2024 | 06/20/2024 |
| MECH | COMPLETE | 06/07/2024 | 06/24/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | HOLD | 06/07/2024 | 06/25/2024 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM SEE BUILDING PLAN REVIEW HOLD COMMENTS | |||
| UD1 | COMPLETE | 06/07/2024 | 06/10/2024 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| IMPACT FEE TRANSPORTATION | ¤1,222.50 | 08/28/2025 |
| IMPACT FEE FIRE | ¤1,725.00 | 08/28/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤2.50 | 02/11/2025 |
| SURCHARGE FS 533.721 | ¤14.45 | 02/11/2025 |
| SURCHARGE - FS 468.631 | ¤21.68 | 02/11/2025 |
| SITE PLAN 30 | ¤30.00 | 02/11/2025 |
| ADJUSTMENT 10% | (¤160.61) | 02/11/2025 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 02/11/2025 |
| INSPECTION COMMERCIAL | ¤1,239.00 | 02/11/2025 |
| INSPECTION - FIRE COMMERCIAL | ¤44.25 | 02/11/2025 |
| PLAN REVIEW - COMMERCIAL | ¤247.80 | 02/11/2025 |
| FC IMPACT FEE EMS | ¤15.00 | 02/11/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤4,476.57 |