Permit #2024090533
Permit Details
Status: COED
| COMMERCIAL SQUARE FOOTAGE: 4250 sqft |
| Total Square Footage: 4250 sqft |
| Block: 02020 |
| Subdivision: - |
| Job Phone: 386-795-3234 |
| Location Address: 11100 US HWY 1 N |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 02/10/2025 |
| NOC: RECORDED |
| Applicant name: CHARLES ANDREW COLEMAN |
| Owner: HORIZON REAL ESTATE FUND LP |
|
Address 220 RIVERSIDE BLVD NEW YORK, NY 10069 |
|
Address APT 46C NEW YORK, NY 10069 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤222,945.00 |
| Job Description: Building 8 - Self Storage |
| Type: CN |
Contractor
COLEMAN GOODEMOTE CONSTRUCTION COMPANY INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
619 N. BEACH ST. DAYTONA BEACH, FL 32114 |
CGC057396 (Exp: 08/31/2026) | 386-257-3570 | 386-253-6692 |
Sub Contractors
SHAUN HAFFNER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
70 N PERROTT DR ORMOND BEACH, FL 32174 |
EC13010602 (Exp: 08/31/2026) | 386-333-9781 | 386-265-1989 |
Inspection History
| Type | Request Date | Result | Inspector |
| EXTERIOR ARCHITECTURAL FEATURES | 10/27/2025 | APPROVED | DRODRIGUEZ |
| U - UTILITY COMMERCIAL FINAL | 10/27/2025 | FINAL APPROVED | BWRIGHT |
| Note: 9/23/2025 - PREVIOUS INSPECTION NOTES | |||
| U - UTILITY COMMERCIAL FINAL | 09/23/2025 | CANCELLED BY APPLICANT | BWRIGHT |
| BUILDING FINAL | 09/23/2025 | APPROVED | FWILLIS |
| FIRE FINAL | 09/23/2025 | APPROVED | RMARTIN |
| ELECTRIC - EARLY POWER | 09/23/2025 | APPROVED | RMARTIN |
| LINTEL | 09/11/2025 | CANCELLED BY INSPECTOR | FWILLIS |
| FRAMING | 09/11/2025 | APPROVED | FWILLIS |
| Note: 7/8/2025 - PREVIOUS INSPECTION NOTES | |||
| INSULATION | 09/11/2025 | APPROVED | FWILLIS |
| Note: 7/15/2025 - PREVIOUS INSPECTION NOTES | |||
| FIREWALL FINAL | 09/04/2025 | FINAL APPROVED | FWILLIS |
| FIREWALL PENETRATIONS | 09/04/2025 | APPROVED | FWILLIS |
| FIREWALL FRAMING | 08/27/2025 | APPROVED | FWILLIS |
| Note: 8/22/2025 - PREVIOUS INSPECTION NOTES | |||
| FIREWALL DRYWALL NAILING | 08/22/2025 | APPROVED | FWILLIS |
| Note: 8/12/2025 - PREVIOUS INSPECTION NOTES 8/11/2025 - PREVIOUS INSPECTION NOTES 8/4/2025 - PREVIOUS INSPECTION NOTES FIRST LAYER | |||
| FIREWALL FRAMING | 08/22/2025 | PARTIALLY APPROVED | FWILLIS |
| ELECTRIC FINAL | 08/15/2025 | APPROVED | MKRASKI |
| ELECTRIC 2ND ROUGH | 08/15/2025 | APPROVED | MKRASKI |
| FIREWALL DRYWALL NAILING | 08/12/2025 | PARTIALLY APPROVED | FWILLIS |
| Note: 8/11/2025 - PREVIOUS INSPECTION NOTES 8/4/2025 - PREVIOUS INSPECTION NOTES FIRST LAYER | |||
| FIREWALL DRYWALL NAILING | 08/11/2025 | PARTIALLY APPROVED | FWILLIS |
| Note: 8/4/2025 - PREVIOUS INSPECTION NOTES FIRST LAYER | |||
| ELECTRIC 2ND ROUGH | 08/07/2025 | PARTIALLY APPROVED | MKRASKI |
| Note: Missing 2nd wall pack per plans on northside of building, call back in once ready | |||
| FIREWALL DRYWALL NAILING | 08/04/2025 | PARTIALLY APPROVED | FWILLIS |
| Note: FIRST LAYER | |||
| ROOF SHEATHING / BRACE / TIE DOWN | 07/15/2025 | APPROVED | FWILLIS |
| INSULATION | 07/15/2025 | PARTIALLY APPROVED | FWILLIS |
| FRAMING | 07/08/2025 | PARTIALLY APPROVED | FWILLIS |
| FOUNDATION SURVEY - OFFICE USE ONLY | 02/27/2025 | APPROVED | DLEAP |
Review History
| Department | Status | Date In | Date Out |
| PLENG | COMPLETE | 02/26/2025 | 02/27/2025 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM | |||
| DSD | COMPLETE | 01/28/2025 | 02/06/2025 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| FI1 | COMPLETE | 01/28/2025 | 02/10/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/28/2025 | 02/10/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ARCHR | COMPLETE | 09/13/2024 | 09/27/2024 |
| Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 09/13/2024 | 10/01/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). 1. It appears that the building does not meet the openining restriction requirements in 705.8.1/Table 705.8. Based on the separation distance shown on the site plan between Building 10 and this building of of 24 feet, unprotected openings in a non-sprinklered building may not exceed 45% of the area of the wall. Openings are well in excess of this percentage. Revise plans to indicate the building is to be provided with an NFPA 13 fire sprinkler system to achieve the unlimited opening area needed for this building. 2.. Provide Product approval number for metal wall panels 107.2.1 3. Upload PEMB plan sheets in separate files. AHJ. 4. Provide verifiable digital seal on each plan sheet. F.A.C.61G15-23.004 5. Provide project street address on each plan sheet. F.A.C. 61G15-30.003(1), 61G15-23.001(4)(b)2.c. 6. Provide reference to steel construction applicable design standard used for building design as referenced in FBCB Chapter 22 and 35 7. Provide correct reference to Risk Category. Occupancy Category II is not appropriate. FBCB Section 1604.5, Table 1604.5 8. Provide complete wind design information. FBCB Section 1603.1.4 No’s 1 through 6. Design wind pressures and their applicable zones with dimensions for exterior component and cladding per Item No 6 appear to be missing. 9. Fire partition is not a Firewall. Revise plans removing reference to partition | |||
| DSD | HOLD | 09/13/2024 | 09/23/2024 |
| Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Permit is on the wrong address. load property to correct address. | |||
| ELEC | COMPLETE | 09/13/2024 | 09/24/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| FI1 | HOLD | 09/13/2024 | 09/26/2024 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please provide a written response to each comment below in a response letter, provide clouded response changes on plan sheets and add page locations for each response. 1. Please include the following code versions the plan sheets anywhere they appear on the plans… NFPA 10, (2018) edition, Standard for Portable Fire Extinguishers NFPA 13, (2019) edition, Standard for the Installation of Sprinkler Systems NFPA 72, (2019) edition, National Fire Alarm and Signaling Code 2. Please provide Classification of hazard of occupancy per FFPC 101, 42.1.2 3. Please provide engineering basis of design for fire sprinkler systems and fire alarm systems as part of these submitted plans. A Florida licensed professional engineer is responsible to establish design concepts established through the Responsibility Rules adopted by the Florida Board of Professional Engineers. F.S. 633.102 (19). Layout of risers, cross mains, branch lines, sprinkler heads, sizing of pipe, hanger locations, and hydraulic calculations in accordance with the design concepts established by the engineer are provided by the licensed fire protection contractor under separate building permit for installation of fire sprinkler and fire alarm systems. 4. MINI STORAGE BUILDING: FFPC 1 13.3.2.27.4 An automatic Sprinkler system is needed for Mini-Storage Buildings greater than 2,500 s/f AND where any of the individual storage units are separated by less than a 1-hour fire resistance-rated barrier. | |||
| GAS | CANCEL | 09/13/2024 | 09/24/2024 |
| MECH | COMPLETE | 09/13/2024 | 09/25/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | CANCEL | 09/13/2024 | 09/25/2024 |
| UD1 | COMPLETE | 09/13/2024 | 09/20/2024 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| IMPACT FEE TRANSPORTATION | ¤2,224.95 | 08/28/2025 |
| IMPACT FEE FIRE | ¤3,139.50 | 08/28/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤4.55 | 02/10/2025 |
| SURCHARGE FS 533.721 | ¤18.04 | 02/10/2025 |
| SURCHARGE - FS 468.631 | ¤27.05 | 02/10/2025 |
| SITE PLAN 30 | ¤30.00 | 02/10/2025 |
| ADJUSTMENT 10% | (¤200.40) | 02/10/2025 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 02/10/2025 |
| INSPECTION COMMERCIAL | ¤1,561.00 | 02/10/2025 |
| INSPECTION - FIRE COMMERCIAL | ¤55.75 | 02/10/2025 |
| PLAN REVIEW - COMMERCIAL | ¤312.20 | 02/10/2025 |
| FC IMPACT FEE EMS | ¤27.30 | 02/10/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤7,274.94 |