I want to search for...

Permit #2025050934

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7010-00070-0320
GARAGE: 476 sqft
CONDITIONED SPACE: 1951 sqft
OPENED PORCH (WITH ROOF) : 354 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
Total Square Footage: 2893 sqft
Block: 00070
Subdivision: -
Job Phone: 386-931-6577
Location Address: 63 FIELDSTONE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/04/2025
NOC: Unknown
Applicant name: LUIS JORGE MEDEIROS
Owner: SILVA VERGILIO & JESSICA I H&W LIFE ESTATE

Address

64 CARPENTER STREET

CUMBERLAND, RI 02864

Lot: 0320
Contracted Stated Job Value: ¤390,000.00
Job Description: Single Family Residence
Type: CN

Contractor

A PLUS HOME IMPROVEMENTS LLC
Status Location Address State License Number Phone
ACTIVE

306 S RAILROAD ST

BUNNELL, FL 32110

CRC1327024 (Exp: 08/31/2026) 386-263-2167

Sub Contractors

LUIS JORGE MEDEIROS
Status Location Address State License Number Phone
INACTIVE

306 S RAILROAD ST

BUNNELL, FL 32110

CCC1335446 (Exp: 08/31/2026) 386-931-6577
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
MIGUEL ANGEL GALLARDO
Status Location Address State License Number Phone
INACTIVE

315 PACER CT

SANFORD, FL 32773

CAC1813826 (Exp: 08/31/2026) 407-202-0953
CHARLES K DAVIS
Status Location Address State License Number Phone
ACTIVE

3000 E MOODY BLVD BLDG 2

BUNNELL , FL 32110

EC13004270 (Exp: 08/31/2026) 386-931-6614

Inspection History

Type Request Date Result Inspector
ELECTRIC - EARLY POWER 05/13/2026 APPROVED - AS NOTED MCONTRYMAN
Note: 5/13/26 Email sent to FPL 5/12/2026 - PREVIOUS INSPECTION NOTES 5/12/26 Previous notes not rectified 1. Missing surge protection in meter/main only NEC 230.67 3. Meter panel in garage not labeled (by final) NEC 408.4 4. Several boxes that have wires/covers are not safed off properly NEC 440.14 4/23/2026 - PREVIOUS INSPECTION NOTES 4/23/26 1. Missing surge protection in meter/main only NEC 230.67 2. No 911 address FBCR 319.2 3. Meter panel in garage not labeled (by final) NEC 408.4 4. Several boxes that have wires/covers are not safed off properly NEC 440.14 --A complete inspection will be required
ELECTRIC - EARLY POWER 05/12/2026 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 5/12/26 Previous notes not rectified 1. Missing surge protection in meter/main only NEC 230.67 3. Meter panel in garage not labeled (by final) NEC 408.4 4. Several boxes that have wires/covers are not safed off properly NEC 440.14 4/23/2026 - PREVIOUS INSPECTION NOTES 4/23/26 1. Missing surge protection in meter/main only NEC 230.67 2. No 911 address FBCR 319.2 3. Meter panel in garage not labeled (by final) NEC 408.4 4. Several boxes that have wires/covers are not safed off properly NEC 440.14 --A complete inspection will be required
SEWER TIE IN 04/24/2026 APPROVED MCONTRYMAN
Note: 4/23/2026 - PREVIOUS INSPECTION NOTES 4/23/36 1. Cannot see sewer connection
ELECTRIC - EARLY POWER 04/23/2026 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 4/23/26 1. Missing surge protection in meter/main only NEC 230.67 2. No 911 address FBCR 319.2 3. Meter panel in garage not labeled (by final) NEC 408.4 4. Several boxes that have wires/covers are not safed off properly NEC 440.14 --A complete inspection will be required
GRAVITY SEWER TEST 04/23/2026 APPROVED MCONTRYMAN
SEWER TIE IN 04/23/2026 Disapproved - NO FEE MCONTRYMAN
Note: 4/23/36 1. Cannot see sewer connection
DRYWALL NAILING 03/09/2026 APPROVED MCONTRYMAN
INSULATION 03/03/2026 APPROVED MCONTRYMAN
Note: 3/2/2026 - PREVIOUS INSPECTION NOTES 3/2/26 1. Missing fire foam in electrical chase for front entry knee wall FBC R302.11 2. Please seal up broken concrete on floor by laundry room area Inspector Notes from Inspection 2420 2/20/26 1. Product approvals need to be changed and submitted for approval to show the Pella windows installed FBC(A) 107.4 2. Need a full, and city approved, energy calc on site by next Inspection. Duct layout on site is correct, but does not look like the original approved in the energy calcs FBC(A) 107.3.1
INSULATION 03/02/2026 Disapproved - NO FEE MCONTRYMAN
Note: 3/2/26 1. Missing fire foam in electrical chase for front entry knee wall FBC R302.11 2. Please seal up broken concrete on floor by laundry room area Inspector Notes from Inspection 2420 2/20/26 1. Product approvals need to be changed and submitted for approval to show the Pella windows installed FBC(A) 107.4 2. Need a full, and city approved, energy calc on site by next Inspection. Duct layout on site is correct, but does not look like the original approved in the energy calcs FBC(A) 107.3.1
ELECTRIC-TUG 03/02/2026 APPROVED MCONTRYMAN
Note: 3/2/26 Email sent to FPL
ALL ROUGH 02/20/2026 APPROVED - AS NOTED MCONTRYMAN
Note: 2/20/26 1. Product approvals need to be changed and submitted for approval to show the Pella windows installed FBC(A) 107.4 2. Need a full, and city approved, energy calc on site by next Inspection. Duct layout on site is correct, but does not look like the original approved in the energy calcs FBC(A) 107.3.1
LATH/BRICK/ WATER BARRIER 02/18/2026 APPROVED HCAMACHO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/10/2026 APPROVED HCAMACHO
Note: 2/2/2026 - PREVIOUS INSPECTION NOTES 2/2/26 1. The previous items have not been fixed yet. Please call back when ready. Roof approved 2. Plans on site need to be larger with stam of approval 12/19/25 1. The plans are missing one page. 2. The Truss Connector shedule thats on the plan does not match the truss #'s (ID), therefore I don't know what belongs to what. 3. There are several Girders in the rear of the house that are doubles and triples that only have one strap. Need connector schedule to verify. 4. One of the girders in the kitchen area that sits on Lanai wall has two straps nailed to the wood but are not in the cement. Marked on wall 5. Bearing walls need anchors to CMU, see detail. Marked on wall 6. Plywood covering knee wall in garage needs to be removed to see anchors.Marked on wall
ROW - DRAINAGE 02/09/2026 APPROVED - AS NOTED PFLANAGAN
Note: THE BUILDER TAKEN OUT TEMP. CULVERT AND SWALE IS OPEN. ITS THE BUILDER RESPOSIBILITY TO KEEP BMPS DURING ENTIRE CONSTRUCTION ------------------------------------------------------------------- 2/6/2026 - PREVIOUS INSPECTION NOTES ** 0206/26 BUILDER CUT OFF THE TEMPORARY CULVERT PIPE REDUCING THE CONSTRUCTION OPENING DOWN TO 10 FT. THE CONSTRUCTION ENTRANCE IS REQUIRED TO BE AMINIMUM OF 16 FT WIDE FROM THE EDGE OF PAVEMENT TO THE ROIGHT OF WAY (ROW) LINE ** SEE DOCUMENT THAT WAS LEFT IN PHOTO SECTION DETAILING THE RESIDENTIAL NEW HOME CONSTRUCTON ENTRANCE ** SEE ATTACHED PHOTOS _______________________________________________________________________________________________________________________ 2/5/2026 - PREVIOUS INSPECTION NOTES 1) NEED TO RE-ESTABLISH SILT FENCES AROUND THE PROPERTY. 2) NEED TO FIX ALL RUTTS AND NEED TO INSTALL CULVERT PIPE CORRERTLY SO WATER WILL FLOW CORRECTLY. PLEASE SEE PHOTOS ATTACHED THIS IS NOW ON AN INSPECTION HOLD. --------------------------------------------------------------------------- 2/4/2026 - PREVIOUS INSPECTION NOTES ** 02/04/26 NO CORRECTIONS HAVE BEEN MADE AT THE TIME OF THIS INSPECTION YOUR PERMIT WILL BE PLACED A PRIORITY (1) STATUS IS ALL CORRECTIOND HAVE NOT BEEN MADE AT THE TIME OF THE NEXT INSPECTION ** BUILDER IS REQUIRED TO RE-SET THE TEMPORARY OR OPEN AND MAINTAIN THE ROADSIDE SWALE AS CURRENTLY YOUR TEMPORARY CULVERT IS NOT EFFECTIVE IN MOVING STORMWATER AS BOTH END OF PIPE ARE POINTING UPWARD. ** RE-ESTABLISH SILT FENCE AROUND WNTIRE PERIMETER OF JOB SITE ** FOLLOW UP INSPECTION ON 02/05/26 __________________________________________________________________________________________________________________________ 1/29/2026 - PREVIOUS INSPECTION NOTES ** 01/29/26 BUILDER IS REQUIRED TO RE-SET THE TEMPORARY OR OPEN AND MAINTAIN THE ROADSIDE SWALE AS CURRENTLY YOUR TEMPORARY CULVERT IS NOT EFFECTIVE IN MOVING STORMWATER AS BOTH END OF PIPE ARE POINTING UPWARD. ** RE-ESTABLISH SILT FENCE AROUND WNTIRE PERIMETER OF JOB SITE ** FOLLOW UP INSPECTION ON 02/04/26
ROW - DRAINAGE 02/06/2026 Disapproved -FEE REQUIRED EMADISON
Note: ** 0206/26 BUILDER CUT OFF THE TEMPORARY CULVERT PIPE REDUCING THE CONSTRUCTION OPENING DOWN TO 10 FT. THE CONSTRUCTION ENTRANCE IS REQUIRED TO BE AMINIMUM OF 16 FT WIDE FROM THE EDGE OF PAVEMENT TO THE ROIGHT OF WAY (ROW) LINE ** SEE DOCUMENT THAT WAS LEFT IN PHOTO SECTION DETAILING THE RESIDENTIAL NEW HOME CONSTRUCTON ENTRANCE _______________________________________________________________________________________________________________________ 2/5/2026 - PREVIOUS INSPECTION NOTES 1) NEED TO RE-ESTABLISH SILT FENCES AROUND THE PROPERTY. 2) NEED TO FIX ALL RUTTS AND NEED TO INSTALL CULVERT PIPE CORRERTLY SO WATER WILL FLOW CORRECTLY. PLEASE SEE PHOTOS ATTACHED THIS IS NOW ON AN INSPECTION HOLD. --------------------------------------------------------------------------- 2/4/2026 - PREVIOUS INSPECTION NOTES ** 02/04/26 NO CORRECTIONS HAVE BEEN MADE AT THE TIME OF THIS INSPECTION YOUR PERMIT WILL BE PLACED A PRIORITY (1) STATUS IS ALL CORRECTIOND HAVE NOT BEEN MADE AT THE TIME OF THE NEXT INSPECTION ** BUILDER IS REQUIRED TO RE-SET THE TEMPORARY OR OPEN AND MAINTAIN THE ROADSIDE SWALE AS CURRENTLY YOUR TEMPORARY CULVERT IS NOT EFFECTIVE IN MOVING STORMWATER AS BOTH END OF PIPE ARE POINTING UPWARD. ** RE-ESTABLISH SILT FENCE AROUND WNTIRE PERIMETER OF JOB SITE ** FOLLOW UP INSPECTION ON 02/05/26 __________________________________________________________________________________________________________________________ 1/29/2026 - PREVIOUS INSPECTION NOTES ** 01/29/26 BUILDER IS REQUIRED TO RE-SET THE TEMPORARY OR OPEN AND MAINTAIN THE ROADSIDE SWALE AS CURRENTLY YOUR TEMPORARY CULVERT IS NOT EFFECTIVE IN MOVING STORMWATER AS BOTH END OF PIPE ARE POINTING UPWARD. ** RE-ESTABLISH SILT FENCE AROUND WNTIRE PERIMETER OF JOB SITE ** FOLLOW UP INSPECTION ON 02/04/26
ROW - DRAINAGE 02/05/2026 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO RE-ESTABLISH SILT FENCES AROUND THE PROPERTY. 2) NEED TO FIX ALL RUTTS AND NEED TO INSTALL CULVERT PIPE CORRERTLY SO WATER WILL FLOW CORRECTLY. PLEASE SEE PHOTOS ATTACHED THIS IS NOW ON AN INSPECTION HOLD. --------------------------------------------------------------------------- 2/4/2026 - PREVIOUS INSPECTION NOTES ** 02/04/26 NO CORRECTIONS HAVE BEEN MADE AT THE TIME OF THIS INSPECTION YOUR PERMIT WILL BE PLACED A PRIORITY (1) STATUS IS ALL CORRECTIOND HAVE NOT BEEN MADE AT THE TIME OF THE NEXT INSPECTION ** BUILDER IS REQUIRED TO RE-SET THE TEMPORARY OR OPEN AND MAINTAIN THE ROADSIDE SWALE AS CURRENTLY YOUR TEMPORARY CULVERT IS NOT EFFECTIVE IN MOVING STORMWATER AS BOTH END OF PIPE ARE POINTING UPWARD. ** RE-ESTABLISH SILT FENCE AROUND WNTIRE PERIMETER OF JOB SITE ** FOLLOW UP INSPECTION ON 02/05/26 __________________________________________________________________________________________________________________________ 1/29/2026 - PREVIOUS INSPECTION NOTES ** 01/29/26 BUILDER IS REQUIRED TO RE-SET THE TEMPORARY OR OPEN AND MAINTAIN THE ROADSIDE SWALE AS CURRENTLY YOUR TEMPORARY CULVERT IS NOT EFFECTIVE IN MOVING STORMWATER AS BOTH END OF PIPE ARE POINTING UPWARD. ** RE-ESTABLISH SILT FENCE AROUND WNTIRE PERIMETER OF JOB SITE ** FOLLOW UP INSPECTION ON 02/04/26
ROW - DRAINAGE 02/04/2026 Disapproved -FEE REQUIRED EMADISON
Note: ** 02/04/26 NO CORRECTIONS HAVE BEEN MADE AT THE TIME OF THIS INSPECTION YOUR PERMIT WILL BE PLACED A PRIORITY (1) STATUS IS ALL CORRECTIOND HAVE NOT BEEN MADE AT THE TIME OF THE NEXT INSPECTION ** BUILDER IS REQUIRED TO RE-SET THE TEMPORARY OR OPEN AND MAINTAIN THE ROADSIDE SWALE AS CURRENTLY YOUR TEMPORARY CULVERT IS NOT EFFECTIVE IN MOVING STORMWATER AS BOTH END OF PIPE ARE POINTING UPWARD. ** RE-ESTABLISH SILT FENCE AROUND WNTIRE PERIMETER OF JOB SITE ** FOLLOW UP INSPECTION ON 02/05/26 __________________________________________________________________________________________________________________________ 1/29/2026 - PREVIOUS INSPECTION NOTES ** 01/29/26 BUILDER IS REQUIRED TO RE-SET THE TEMPORARY OR OPEN AND MAINTAIN THE ROADSIDE SWALE AS CURRENTLY YOUR TEMPORARY CULVERT IS NOT EFFECTIVE IN MOVING STORMWATER AS BOTH END OF PIPE ARE POINTING UPWARD. ** RE-ESTABLISH SILT FENCE AROUND WNTIRE PERIMETER OF JOB SITE ** FOLLOW UP INSPECTION ON 02/04/26
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/02/2026 Disapproved -FEE REQUIRED MKRASKI
Note: 2/2/26 1. The previous items have not been fixed yet. Please call back when ready. Roof approved 2. Plans on site need to be larger with stam of approval 12/19/25 1. The plans are missing one page. 2. The Truss Connector shedule thats on the plan does not match the truss #'s (ID), therefore I don't know what belongs to what. 3. There are several Girders in the rear of the house that are doubles and triples that only have one strap. Need connector schedule to verify. 4. One of the girders in the kitchen area that sits on Lanai wall has two straps nailed to the wood but are not in the cement. Marked on wall 5. Bearing walls need anchors to CMU, see detail. Marked on wall 6. Plywood covering knee wall in garage needs to be removed to see anchors.Marked on wall
ROW - DRAINAGE 01/29/2026 Disapproved - NO FEE EMADISON
Note: ** 01/29/26 BUILDER IS REQUIRED TO RE-SET THE TEMPORARY OR OPEN AND MAINTAIN THE ROADSIDE SWALE AS CURRENTLY YOUR TEMPORARY CULVERT IS NOT EFFECTIVE IN MOVING STORMWATER AS BOTH END OF PIPE ARE POINTING UPWARD. ** RE-ESTABLISH SILT FENCE AROUND WNTIRE PERIMETER OF JOB SITE ** FOLLOW UP INSPECTION ON 02/04/26
ROOF VALLEY & METAL 01/09/2026 APPROVED - AS NOTED HCAMACHO
Note: ok to load roof
WALL SHEATHING 01/09/2026 APPROVED - AS NOTED HCAMACHO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/09/2026 Disapproved - NO FEE HCAMACHO
Note: *Roof Sheathing is ok* 1- The previous items have not been fixed yet. Please call back when ready. 12/19/2025 - PREVIOUS INSPECTION NOTES 1. The plans are missing one page. 2. The Truss Connector shedule thats on the plan does not match the truss #'s (ID), therefore I don't know what belongs to what. 3. There are several Girders in the rear of the house that are doubles and triples that only have one strap. Need connector schedule to verify. 4. One of the girders in the kitchen area that sits on Lanai wall has two straps nailed to the wood but are not in the cement. Marked on wall 5. Bearing walls need anchors to CMU, see detail. Marked on wall 6. Plywood covering knee wall in garage needs to be removed to see anchors.Marked on wall
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/19/2025 Disapproved - NO FEE HCAMACHO
Note: 1. The plans are missing one page. 2. The Truss Connector shedule thats on the plan does not match the truss #'s (ID), therefore I don't know what belongs to what. 3. There are several Girders in the rear of the house that are doubles and triples that only have one strap. Need connector schedule to verify. 4. One of the girders in the kitchen area that sits on Lanai wall has two straps nailed to the wood but are not in the cement. Marked on wall 5. Bearing walls need anchors to CMU, see detail. Marked on wall 6. Plywood covering knee wall in garage needs to be removed to see anchors.Marked on wall
TIE BEAM / LINTEL 09/17/2025 APPROVED HCAMACHO
MONOLITHIC SLAB 08/12/2025 APPROVED HCAMACHO
MONOLITHIC SLAB 08/08/2025 CANCELLED BY APPLICANT JSTEWART
Note: via phone
FORMBOARD SURVEY (OFFICE USE ONLY) 07/23/2025 APPROVED RRICKS
PLUMBING 1ST ROUGH UNDERGROUND 07/22/2025 APPROVED HCAMACHO
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 07/21/2025 APPROVED JMUNSON
WATER METER INSTALLATION REQUEST 07/10/2025 APPROVED CBOWERMASTER
WILDLIFE CHECK - ENVIRONMENTAL 05/22/2025 APPROVED DRODRIGUEZ
BLD - BUILDING FINAL
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
ROW- FINAL SURVEY/GRADING CERTIFICATION
ROW FIELD SURVEY /GRADING CERTIFICATION
ROW - STORMWATER FINAL
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
BLD COMPLETE 02/24/2026 03/02/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 02/11/2026 02/18/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 09/17/2025 09/17/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 09/17/2025 09/17/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 COMPLETE 07/23/2025 07/23/2025
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 07/23/2025 07/23/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD HOLD 07/18/2025 07/18/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit certification letter
BLD COMPLETE 07/18/2025 07/21/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 07/07/2025 07/10/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit certification letter and density reports.
ELEC COMPLETE 05/30/2025 06/02/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 05/30/2025 06/02/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 05/30/2025 06/02/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 05/22/2025 06/17/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BADMIN COMPLETE 05/21/2025 05/28/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 05/21/2025 05/28/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Need comment in plans regarding soil bearing capacity. FBC R404.5.2 2. Provide complete truss plan submittal packet to include all of the following: A. Complete truss plan packet, signed and sealed by a Florida licensed professional engineer (the truss design engineer) B. Truss layout / placement plan from truss manufacturer C. Truss profile plan sheets for all trusses. D. Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal)
CUSVC COMPLETE 05/21/2025 05/29/2025
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 05/21/2025 05/23/2025
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Electrical load calcs do not match the living space of the home.
ENGIN1 COMPLETE 05/21/2025 05/22/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 05/21/2025 05/23/2025
LOCATE COMPLETE 05/21/2025 05/23/2025
Note: Released By: BRITTANY VITALE - -
MECH HOLD 05/21/2025 05/27/2025
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide engineered wall section showing from roof deck to foundation with insulation value. (missing page 5 of 6. It could be that page. If not provide from engineer.)
SW1 COMPLETE 05/21/2025 05/22/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 05/21/2025 05/22/2025
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
PLENV COMPLETE 05/21/2025 05/22/2025
Note: Released By: DYLAN RODRIGUEZ - - DRODRIGUEZ@PALMCOASTGOV.COM Staff conducted a site visit on 05/22/25 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. If any gopher tortoises are located in the future further coordination may be necessary.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
WATER-METER ¤965.03 06/04/2025
WATER- TURN ON ¤50.00 06/04/2025
WATER- TURN ON ¤50.00 06/04/2025
ADJUSTMENT 10% (¤140.67) 06/04/2025
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/04/2025
INSPECTION - RESIDENTIAL ¤1,072.50 06/04/2025
PLAN REVIEW - RESIDENTIAL ¤304.20 06/04/2025
FC IMPACT FEE EMS ¤62.00 06/04/2025
IMPACT FEE FIRE ¤434.51 06/04/2025
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 06/04/2025
FC IMPACT FEE LIBRARY ¤268.00 06/04/2025
IMPACT FEE PARKS ¤1,828.01 06/04/2025
IMPACT FEE SCHOOL ¤5,450.00 06/04/2025
IMPACT FEE TRANSPORTATION ¤1,916.00 06/04/2025
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 06/04/2025
SURCHARGE FS 533.721 ¤12.66 06/04/2025
SURCHARGE - FS 468.631 ¤18.99 06/04/2025
SW ENG - FOUNDATION SURVEY ¤20.00 06/04/2025
SW ENG INSPECTION 80 ¤80.00 06/04/2025
SW ENG PRE APRON ¤30.00 06/04/2025
SW ENG - REVIEW 20 ¤20.00 06/04/2025
SW ENG RES REVIEW 200 ¤200.00 06/04/2025
WATER METER W/ TAP ¤2,326.93 06/04/2025
SEWER CREDIT (¤1,146.90) 06/04/2025
WASTEWATER PERM INSPECTION ¤80.00 06/04/2025
WASTEWATER PERM REVIEW ¤25.00 06/04/2025
SEWER CAPITAL FACILITY ¤4,415.00 06/04/2025
WATER CAPITAL FACILITY FEE ¤3,790.49 06/04/2025
WATER PERMIT INSPECTION ¤40.00 06/04/2025
WATER PERMIT REVIEW ¤25.00 06/04/2025
WATER MAIN EXTENSION IMPACT ¤917.27 06/04/2025
SITE PLAN 30 ¤30.00 06/04/2025
RSI REINSPECTION 1 ¤35.00
RSI REINSPECTION 1 ¤35.00
RSI REINSPECTION 1 ¤35.00
RSI REINSPECTION 1 ¤35.00
RSI REINSPECTION 2 ¤75.00
REINSPECTION RESIDENTIAL ¤40.00
REINSPECTION RESIDENTIAL ¤40.00
REINSPECTION RESIDENTIAL ¤40.00
CONTRACTOR CHANGE ¤20.00
Fees Total Due: ¤355.00 Total Paid: ¤25,777.02