I want to search for...
Permit #2025070563
Permit Details
Status: COED
| Parcel Id: 06-12-31-5182-00000-0870 |
| CONDITIONED SPACE: 1809 sqft |
| GARAGE: 400 sqft |
| OPENED PORCH (WITH ROOF) : 175 sqft |
| Total Square Footage: 2384 sqft |
| Subdivision: 2345 - RETREAT TOWN CENTER PHASE 2 |
| Job Phone: 904-669-7000 |
| Location Address: 46 MULBERRY RD |
| Type: TH - TOWNHOUSE |
| Issue Date: 08/04/2025 |
| NOC: RECORDED |
| Applicant name: PAUL GILBERT AXTELL |
| Owner: TOLL SOUTHEAST LP CO INC |
|
Address 1140 VIRGINIA DRIVE FORT WASHINGTON, PA 19034 |
| Lot: 87 |
| Contracted Stated Job Value: ¤340,061.08 |
| Job Description: TOWNHOME |
| Type: CN |
Contractor
TOLL BROS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
40 EVEREST LN, STE 5 ST JOHNS, FL 32259 |
CGC60445 (Exp: 08/31/2026) | 904-217-3852 |
Sub Contractors
JAMES F QUINN III
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3210 SW 40TH BLVD STE F GAINESVILLE, FL 32608 |
EC13010994 (Exp: 08/31/2026) | 352-378-9274 |
PAUL ERIC FORSTER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6114 GOODMAN RD JACKSONVILLE, FL 32244 |
CFC1429261 (Exp: 08/31/2026) | 904-647-1820 |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
HARLEY M BRYAN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
5223 EDGEWOOD CT ORMOND BEACH, FL 32174 |
LI26657 (Exp: 08/31/2028) | 386-463-2700 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 12/30/2025 | FINAL APPROVED | BTAYLOR |
| U -UTILITY RESIDENTIAL FINAL | 11/14/2025 | FINAL APPROVED | BHAINES |
| Note: Inspector Notes from Inspection 9035 No CC, IRR with reclaim. | |||
| U-CROSS CONNECTION | 11/12/2025 | APPROVED - AS NOTED | BHAINES |
| Note: No CC, IRR with reclaim. | |||
| LDSC- LANDSCAPE FINAL | 11/12/2025 | APPROVED | RPICATAGI |
| ELECTRIC - EARLY POWER | 11/07/2025 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 11/7/2025 8:44:27 AM *** 11/7/25: FPL emailed to release power. Inspector Notes from Inspection 2200 10/2/25 Email sent to FPL | |||
| GAS ROUGH | 11/05/2025 | APPROVED | MGIBSON |
| FIREWALL DRYWALL NAILING | 10/06/2025 | APPROVED | JSTEWART |
| ELECTRIC-TUG | 10/02/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 10/2/25 Email sent to FPL | |||
| SEWER TIE IN | 09/26/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS APPROVED ON 9/25/25 AS A VIRTUAL NOT A PARTIAL APPROVED 9/25/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION THIS WAS A VIRTUAL INSPECTION | |||
| GRAVITY SEWER TEST | 09/25/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| SEWER TIE IN | 09/25/2025 | PARTIALLY APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2075 THIS WAS A VIRTUAL INSPECTION THIS WAS A VIRTUAL INSPECTION | |||
| INSULATION | 09/25/2025 | APPROVED | MCONTRYMAN |
| Note: Inspector Notes from Inspection 2320 9/22/25 1. Upon inspection an electrical box was seen in the soffit firewall in the back of the house. This is not allowed as it penetrates the firewall seperation. You will need to move the box, and wires over, and replace the firewall seperation in the soffit. | |||
| LATH/BRICK/ WATER BARRIER | 09/22/2025 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 9/22/25 1. Upon inspection an electrical box was seen in the soffit firewall in the back of the house. This is not allowed as it penetrates the firewall seperation. You will need to move the box, and wires over, and replace the firewall seperation in the soffit. | |||
| ALL ROUGH | 09/18/2025 | APPROVED - AS NOTED | JSTEWART |
| Note: Multiple Bath Exhaust duct are damaged in the attic space (torn). please repair Exhaust ducts require lift and secured to trusses to eliminate sag, and flat spots for condinsation build up. FBMC 603.8.1 Slope. Ducts shall have a minimum slope of 1/8 inch per foot (10.4 mm/m) to allow drainage to a point provided with access. FBMC 501.3 Exhaust discharge. The air removed by every mechanical exhaust system shall be discharged outdoors ......... FBCR M1601.4.1 DUCT WORK NOT SEALED Will check at insulation. 9/12/2025 - PREVIOUS INSPECTION NOTES 9/12/25 Okay to install porch lids on porch and lanai (only inspected these items) | |||
| FIREWALL FRAMING | 09/18/2025 | APPROVED | JSTEWART |
| FIREWALL PENETRATIONS | 09/18/2025 | APPROVED | JSTEWART |
| WATER METER INSTALLATION REQUEST | 09/15/2025 | APPROVED | CBOWERMASTER |
| ALL ROUGH | 09/12/2025 | PARTIALLY APPROVED | MCONTRYMAN |
| Note: 9/12/25 Okay to install porch lids on porch and lanai (only inspected these items) | |||
| ROOF VALLEY & METAL | 09/03/2025 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/02/2025 | APPROVED | FWILLIS |
| WALL SHEATHING | 08/29/2025 | APPROVED | MCONTRYMAN |
| MONOLITHIC SLAB | 08/13/2025 | APPROVED | FWILLIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 08/12/2025 | APPROVED | MGIBSON |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 08/11/2025 | APPROVED | DLEAP |
Review History
| Department | Status | Date In | Date Out |
| PLENG | COMPLETE | 11/18/2025 | 11/18/2025 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM | |||
| PLENG | COMPLETE | 09/05/2025 | 09/05/2025 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM Plan submitted on 9/5/25 was incorrect. Plan review and approved on 7/28/25. | |||
| ELEC | COMPLETE | 07/29/2025 | 07/31/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/29/2025 | 08/04/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| PLENG | COMPLETE | 07/28/2025 | 07/28/2025 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 07/24/2025 | 07/24/2025 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Site plan should be uploaded under the site plan document type (not plans) and use the same file name as previously used if submitting a correction. | |||
| ARCHR | COMPLETE | 07/15/2025 | 07/21/2025 |
| Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 07/15/2025 | 07/22/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 07/15/2025 | 07/22/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Product Approval FL# 31114-R3 not a sliding glass door | |||
| DSD | COMPLETE | 07/15/2025 | 07/24/2025 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 07/15/2025 | 07/22/2025 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit electrical load calcs | |||
| FI1 | CANCEL | 07/15/2025 | 07/17/2025 |
| GAS | COMPLETE | 07/15/2025 | 07/16/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/15/2025 | 07/17/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLENG | HOLD | 07/15/2025 | 07/16/2025 |
| Note: Held By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM 1. The drainage flow arrows along the side lot lines at the rear of the property are going in the wrong direction. Review and revise accordingly. | |||
| PLLA | COMPLETE | 07/15/2025 | 07/21/2025 |
| Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM | |||
| PLUM | COMPLETE | 07/15/2025 | 07/17/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| UD1 | COMPLETE | 07/15/2025 | 07/22/2025 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER-METER | ¤874.47 | 08/05/2025 |
| WATER- TURN ON | ¤50.00 | 08/05/2025 |
| WATER METER W/OUT TAP | ¤965.03 | 08/05/2025 |
| WATER PERMIT INSPECTION | ¤40.00 | 08/05/2025 |
| WATER PERMIT REVIEW | ¤25.00 | 08/04/2025 |
| SITE PLAN 30 | ¤30.00 | 08/04/2025 |
| SURCHARGE FS 533.721 | ¤11.10 | 08/04/2025 |
| SURCHARGE - FS 468.631 | ¤16.66 | 08/04/2025 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 08/04/2025 |
| WASTEWATER PERM REVIEW | ¤25.00 | 08/04/2025 |
| ADJUSTMENT 10% | (¤123.37) | 08/04/2025 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/04/2025 |
| INSPECTION - RESIDENTIAL | ¤937.75 | 08/04/2025 |
| PLAN REVIEW - RESIDENTIAL | ¤265.98 | 08/04/2025 |
| FC IMPACT FEE EMS | ¤62.00 | 08/04/2025 |
| IMPACT FEE FIRE | ¤434.51 | 08/04/2025 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 08/04/2025 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 08/04/2025 |
| IMPACT FEE PARKS | ¤1,828.01 | 08/04/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 08/04/2025 |
| IMPACT FEE TRANSPORTATION | ¤2,715.00 | 08/04/2025 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤14,203.14 |