I want to search for...
Permit #2025110392
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7002-00010-0080 |
| Block: 00010 |
| Subdivision: 7002 - |
| Job Phone: 386-931-6577 |
| Location Address: 15 FARRADAY LN |
| Type: DR - DRIVEWAY |
| Issue Date: 02/12/2026 |
| NOC: RECORDED |
| Applicant name: LUIS JORGE MEDEIROS |
| Owner: MISZTAL JERZY |
|
Address 15 FARRADAY LANE PALM COAST, FL 32137 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤15,000.00 |
| Job Description: New Paver Driveway |
| Type: CN |
Contractor
A PLUS HOME IMPROVEMENTS LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
306 S RAILROAD ST BUNNELL, FL 32110 |
CRC1327024 (Exp: 08/31/2026) | 386-263-2167 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW- PRE-APRON (PRE-POUR) | 03/03/2026 | APPROVED - AS NOTED | EMADISON |
| Note: ** 03/03/26 READY TO SET PAVERS ENSURE COMPACTION IF PAVERS NOT FINISHED _________________________________________________________________________________________________________________________ 2/13/2026 - PREVIOUS INSPECTION NOTES BASE WAS DOWN BUT IT WASN'T AT FINISH GRADE NEED TO REMOVE ALL HIGH SPOTS MUST CALL IN ANOTHER PRE POUR WHEN BASE IS FINISHED. READY TO POUR APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. ---------------------------------------------------------------------- NOTE TO INSPECTOR MET WITH LUIS AND GOT WITH ENGINEERING AND THEY ARE GOING TO PUT THE INVERT OF THE CULVERT PIPE FOR THIS DRIVEWAY AT 6.05 TO HELP WITH THE CULVERT BEING INTO UTILITIES UNDER THE POURING AREA. PLEASE SEE NEW SWALE PLAN DETAIL FOR NEW INVERT OR LOOK AT THE NOTES HERE FOR THE NEW INVERT. ANY QUESTIONS CALL PARREN OR JOHN HOWERD IN ENGINEERING. | |||
| ROW- PRE-APRON (PRE-POUR) | 02/13/2026 | PARTIALLY APPROVED | PFLANAGAN |
| Note: BASE WAS DOWN BUT IT WASN'T AT FINISH GRADE NEED TO REMOVE ALL HIGH SPOTS MUST CALL IN ANOTHER PRE POUR WHEN BASE IS FINISHED. READY TO POUR APRON AND PAVER RESTRAINTS ONLY. BEFORE NEXT PRE POUR ALL PAVER BASE NEEDS TO SPREAD AND COMPACTED TO CITY'S STANDARDS WITH NO PAVERS LAID AT THE TIME OF THE INSPECTION. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. ---------------------------------------------------------------------- NOTE TO INSPECTOR MET WITH LUIS AND GOT WITH ENGINEERING AND THEY ARE GOING TO PUT THE INVERT OF THE CULVERT PIPE FOR THIS DRIVEWAY AT 6.05 TO HELP WITH THE CULVERT BEING INTO UTILITIES UNDER THE POURING AREA. PLEASE SEE NEW SWALE PLAN DETAIL FOR NEW INVERT OR LOOK AT THE NOTES HERE FOR THE NEW INVERT. ANY QUESTIONS CALL PARREN OR JOHN HOWERD IN ENGINEERING. | |||
| ROW- PROJECT STATUS | 01/30/2026 | Status Check | PFLANAGAN |
| Note: NOTE TO INSPECTOR MET WITH LUIS AND GOT WITH ENGINEERING AND THEY ARE GOING TO PUT THE INVERT OF THE CULVERT PIPE FOR THIS DRIVEWAY AT 6.05 TO HELP WITH THE CULVERT BEING INTO UTILITIES UNDER THE POURING AREA. PLEASE SEE NEW SWALE PLAN DETAIL FOR NEW INVERT OR LOOK AT THE NOTES HERE FOR THE NEW INVERT. ANY QUESTIONS CALL PARREN OR JOHN HOWERD IN ENGINEERING. ---------------------------------------------------------------------------------- Please- contact the builder Luis Medeiros at 386- 931-6577 For the driveway culvert | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| SWALE | COMPLETE | 02/02/2026 | 02/02/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM Elevation of culvert raised due to shallow existing utilities. | |||
| ENGIN1 | COMPLETE | 11/21/2025 | 11/24/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/21/2025 | 11/21/2025 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Pleae drop off the originals for the right of way | |||
| RSI | COMPLETE | 11/21/2025 | 11/21/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 11/13/2025 | 11/14/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 11/12/2025 | 11/13/2025 |
| Note: Held By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM This property will require a culvert to be installed. Please include the culvert information on the site plan. New culverts must meet city standards, be a diameter equal to 15" (13"x17" eliptical or 15" circular), be made of alluminized CMP or HDPE, and extend a minimum of 3' past the driveway on both sides to allow for the construction of the mitered end sections. | |||
| RSI | HOLD | 11/12/2025 | 11/14/2025 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM MUST HAVE TYPE OF CULVERT PIPE AND THE LENGTH OF THE CULVERT | |||
| UTL | COMPLETE | 11/12/2025 | 11/12/2025 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | HOLD | 11/12/2025 | 11/13/2025 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Driveway needs to leads to the garage doors not right up to the home. Please modify the plans. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/12/2026 |
| RECORDING FEE REIMBURSE DOC | ¤44.00 | 02/12/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 02/12/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 02/12/2026 |
| RSI GENERAL INSPECTION 32.50 | ¤32.50 | 02/12/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 02/12/2026 |
| RSI SITE PLAN REVIEW | ¤16.25 | 02/12/2026 |
| SW ENG RES REVIEW 240 | ¤240.00 | 02/12/2026 |
| SITE PLAN 15 | ¤15.00 | 02/12/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤442.75 |