I want to search for...

Permit #2026020199

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7033-00470-0010
CONDITIONED SPACE: 2721 sqft
GARAGE: 469 sqft
OPENED PORCH (WITH ROOF) : 103 sqft
OPENED PORCH (WITH ROOF) : 145 sqft
Total Square Footage: 3438 sqft
Block: 00470
Subdivision: 2184 - SECTION 33-ROYAL PALMS
Job Phone: 386-254-5081
Location Address: 18 RENMONT PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/26/2026
NOC: RECORDED
Applicant name: WILLIAM BRYAN ADAMS SR
Owner: ADAMS HOMES OF NORTHWEST FLORIDA INC

Address

100 WEST GARDEN STREET

PENSACOLA, FL 32502

Address

SECOND FLOOR

PENSACOLA, FL 32502

Lot: 0010
Contracted Stated Job Value: ¤212,000.00
Job Description: Single Family Residence
Type: CN

Contractor

ADAMS HOMES OF NORTHWEST FLORIDA, INC
Status Location Address State License Number Phone
ACTIVE

3000 GULF BREEZE PARKWAY

GULD BREEZE, FL 32563

CRC1330146 (Exp: 08/31/2026) 386-254-5081

Sub Contractors

TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910
ROBERTO F GONZALEZ
Status Location Address State License Number Phone
ACTIVE

212 PALMETTO AVE

CRESCENT CITY, FL 32112

RF11067887 (Exp: 08/31/2027) 286-559-2885
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
MICHAEL THACKABERRY
Status Location Address State License Number Phone
ACTIVE

18115 DEMKO RD

ALTOONA, FL 32702

CCC1336911 (Exp: 08/31/2026) 517-499-5016

Inspection History

Type Request Date Result Inspector
DRYWALL NAILING 06/03/2026 APPROVED CVANSTRAHLEN
INSULATION 05/29/2026 APPROVED CVANSTRAHLEN
Note: 5/28/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC R302.11 FBC-FIRESTOPPING INSTALLED ( several annular penetration garage area walls , first floor area plumbing water lines and DWV required to be seal , second floor annular penetration required to be seal ( mark with red sharpie market ) #2-ceiling over garage required to have 5/8 drywall install #3-required fire bloking on second floor , corner by share bathroom Inspector Notes from Inspection 2320 Will chek items front previous inspection on insulation inspection #1NEC 230.24(B) outlines the minimum vertical clearances required for overhead service conductors from final grade. These clearances must be maintained even under conditions of maximum conductor sag-10 feet: Above sidewalks, platforms, and areas accessible only to pedestrians. (Applies only to 120/208V or 120/240V systems not exceeding 150V to ground).NEC Section 230.26 establishes the rules for the Point of Attachment of overhead service conductors (the service drop) to a building or structure.It mandates that this point of attachment must be high enough to allow the service conductors to meet all minimum vertical clearance requirements, and in no case shall the attachment point be less than 10 feet (3.0 meters) above finished grade. #1-NEC-#8-Missing AC register on second floor by hallway #4 size Please fix items before next inspection #1-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW #2-FBCR P2605.1-PIPE SUPPORT CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL ( some dwv over wall level ) #3- FL, the Florida Building Code requires your dryer vent to terminate at least 3 feet in any direction from doors, windows, and ventilated soffits. It must also be a minimum of 3 feet from property lines and 12 inches above the ground. #4-NEC-200.6 (B)-Side 4 AWG or large an isulated grounded conductor shall be identified ( electrical main panel) not mark with sharpie < required to used electrical tape ) #5-). All bathroom exhaust fans require two points of connection and Master bathroom exhausts need to be sealed properly at roof deck. Also, Master bathroom exhaust are not sealed/connected onto fan sleeve (correctly) as required. FBC-M1502.4.2 / FBC-M1601.4.1.). #6-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( one window in the first floor #7-missing window second floor ( front ) *** NOTES ADDED BY CVANSTRAHLEN 5/22/2026 10:08:43 AM *** #7-Missing AC register on second floor by hallway #4 size Please fix items before next inspection #1-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW #2-FBCR P2605.1-PIPE SUPPORT CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL ( some dwv over wall level ) #3- FL, the Florida Building Code requires your dryer vent to terminate at least 3 feet in any direction from doors, windows, and ventilated soffits. It must also be a minimum of 3 feet from property lines and 12 inches above the ground. #4-NEC-200.6 (B)-Side 4 AWG or large an isulated grounded conductor shall be identified ( electrical main panel) not mark with sharpie < required to used electrical tape ) #5-). All bathroom exhaust fans require two points of connection and Master bathroom exhausts need to be sealed properly at roof deck. Also, Master bathroom exhaust are not sealed/connected onto fan sleeve (correctly) as required. FBC-M1502.4.2 / FBC-M1601.4.1.). #6-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( one window in the first floor )
INSULATION 05/28/2026 Disapproved - NO FEE CVANSTRAHLEN
Note: Please fix items before next inspection #1-FBC R302.11 FBC-FIRESTOPPING INSTALLED ( several annular penetration garage area walls , first floor area plumbing water lines and DWV required to be seal , second floor annular penetration required to be seal ( mark with red sharpie market ) #2-ceiling over garage required to have 5/8 drywall install #3-required fire bloking on second floor , corner by share bathroom Inspector Notes from Inspection 2320 Will chek items front previous inspection on insulation inspection #1NEC 230.24(B) outlines the minimum vertical clearances required for overhead service conductors from final grade. These clearances must be maintained even under conditions of maximum conductor sag-10 feet: Above sidewalks, platforms, and areas accessible only to pedestrians. (Applies only to 120/208V or 120/240V systems not exceeding 150V to ground).NEC Section 230.26 establishes the rules for the Point of Attachment of overhead service conductors (the service drop) to a building or structure.It mandates that this point of attachment must be high enough to allow the service conductors to meet all minimum vertical clearance requirements, and in no case shall the attachment point be less than 10 feet (3.0 meters) above finished grade. #1-NEC-#8-Missing AC register on second floor by hallway #4 size Please fix items before next inspection #1-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW #2-FBCR P2605.1-PIPE SUPPORT CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL ( some dwv over wall level ) #3- FL, the Florida Building Code requires your dryer vent to terminate at least 3 feet in any direction from doors, windows, and ventilated soffits. It must also be a minimum of 3 feet from property lines and 12 inches above the ground. #4-NEC-200.6 (B)-Side 4 AWG or large an isulated grounded conductor shall be identified ( electrical main panel) not mark with sharpie < required to used electrical tape ) #5-). All bathroom exhaust fans require two points of connection and Master bathroom exhausts need to be sealed properly at roof deck. Also, Master bathroom exhaust are not sealed/connected onto fan sleeve (correctly) as required. FBC-M1502.4.2 / FBC-M1601.4.1.). #6-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( one window in the first floor #7-missing window second floor ( front ) *** NOTES ADDED BY CVANSTRAHLEN 5/22/2026 10:08:43 AM *** #7-Missing AC register on second floor by hallway #4 size Please fix items before next inspection #1-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW #2-FBCR P2605.1-PIPE SUPPORT CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL ( some dwv over wall level ) #3- FL, the Florida Building Code requires your dryer vent to terminate at least 3 feet in any direction from doors, windows, and ventilated soffits. It must also be a minimum of 3 feet from property lines and 12 inches above the ground. #4-NEC-200.6 (B)-Side 4 AWG or large an isulated grounded conductor shall be identified ( electrical main panel) not mark with sharpie < required to used electrical tape ) #5-). All bathroom exhaust fans require two points of connection and Master bathroom exhausts need to be sealed properly at roof deck. Also, Master bathroom exhaust are not sealed/connected onto fan sleeve (correctly) as required. FBC-M1502.4.2 / FBC-M1601.4.1.). #6-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( one window in the first floor )
LATH/BRICK/ WATER BARRIER 05/27/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: Will chek items front previous inspection on insulation inspection #1NEC 230.24(B) outlines the minimum vertical clearances required for overhead service conductors from final grade. These clearances must be maintained even under conditions of maximum conductor sag-10 feet: Above sidewalks, platforms, and areas accessible only to pedestrians. (Applies only to 120/208V or 120/240V systems not exceeding 150V to ground).NEC Section 230.26 establishes the rules for the Point of Attachment of overhead service conductors (the service drop) to a building or structure.It mandates that this point of attachment must be high enough to allow the service conductors to meet all minimum vertical clearance requirements, and in no case shall the attachment point be less than 10 feet (3.0 meters) above finished grade. #1-NEC-#8-Missing AC register on second floor by hallway #4 size Please fix items before next inspection #1-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW #2-FBCR P2605.1-PIPE SUPPORT CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL ( some dwv over wall level ) #3- FL, the Florida Building Code requires your dryer vent to terminate at least 3 feet in any direction from doors, windows, and ventilated soffits. It must also be a minimum of 3 feet from property lines and 12 inches above the ground. #4-NEC-200.6 (B)-Side 4 AWG or large an isulated grounded conductor shall be identified ( electrical main panel) not mark with sharpie < required to used electrical tape ) #5-). All bathroom exhaust fans require two points of connection and Master bathroom exhausts need to be sealed properly at roof deck. Also, Master bathroom exhaust are not sealed/connected onto fan sleeve (correctly) as required. FBC-M1502.4.2 / FBC-M1601.4.1.). #6-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( one window in the first floor #7-missing window second floor ( front ) *** NOTES ADDED BY CVANSTRAHLEN 5/22/2026 10:08:43 AM *** #7-Missing AC register on second floor by hallway #4 size Please fix items before next inspection #1-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW #2-FBCR P2605.1-PIPE SUPPORT CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL ( some dwv over wall level ) #3- FL, the Florida Building Code requires your dryer vent to terminate at least 3 feet in any direction from doors, windows, and ventilated soffits. It must also be a minimum of 3 feet from property lines and 12 inches above the ground. #4-NEC-200.6 (B)-Side 4 AWG or large an isulated grounded conductor shall be identified ( electrical main panel) not mark with sharpie < required to used electrical tape ) #5-). All bathroom exhaust fans require two points of connection and Master bathroom exhausts need to be sealed properly at roof deck. Also, Master bathroom exhaust are not sealed/connected onto fan sleeve (correctly) as required. FBC-M1502.4.2 / FBC-M1601.4.1.). #6-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( one window in the first floor )
ALL ROUGH 05/21/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: *** NOTES ADDED BY CVANSTRAHLEN 5/22/2026 10:08:43 AM *** #7-Missing AC register on second floor by hallway #4 size Please fix items before next inspection #1-FBCR P2503.7-NEEDS WATER TEST ON DWV - 5 FT HEAD PRESSURE ABOVE HIGHEST FIXTURE - FILL TUB TO OVERFLOW #2-FBCR P2605.1-PIPE SUPPORT CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL ( some dwv over wall level ) #3- FL, the Florida Building Code requires your dryer vent to terminate at least 3 feet in any direction from doors, windows, and ventilated soffits. It must also be a minimum of 3 feet from property lines and 12 inches above the ground. #4-NEC-200.6 (B)-Side 4 AWG or large an isulated grounded conductor shall be identified ( electrical main panel) not mark with sharpie < required to used electrical tape ) #5-). All bathroom exhaust fans require two points of connection and Master bathroom exhausts need to be sealed properly at roof deck. Also, Master bathroom exhaust are not sealed/connected onto fan sleeve (correctly) as required. FBC-M1502.4.2 / FBC-M1601.4.1.). #6-FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS ( one window in the first floor )
WALL SHEATHING 05/13/2026 APPROVED CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/13/2026 APPROVED CVANSTRAHLEN
ROOF VALLEY & METAL 05/13/2026 APPROVED CVANSTRAHLEN
MONOLITHIC SLAB 04/20/2026 APPROVED CVANSTRAHLEN
PLUMBING 1ST ROUGH UNDERGROUND 04/15/2026 APPROVED KSANDOE
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 04/13/2026 APPROVED PKNAPIK
FORMBOARD SURVEY (OFFICE USE ONLY) 04/06/2026 APPROVED PFLANAGAN
WATER METER INSTALLATION REQUEST 03/27/2026 APPROVED ISANDERSON
PEP TANK INSTALLATION REQUEST
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
GRAVITY SEWER TEST
SEWER TIE IN
ELECTRIC - EARLY POWER
BLD - BUILDING FINAL

Review History

Department Status Date In Date Out
BLD COMPLETE 04/13/2026 04/13/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 04/06/2026 04/06/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 04/06/2026 04/06/2026
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
BLD COMPLETE 03/26/2026 03/26/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ZON COMPLETE 02/19/2026 02/19/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 02/18/2026 02/18/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 02/06/2026 02/12/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD HOLD 02/05/2026 02/10/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Provide geotechnical investigation report in accordance with FBCB Section 1803.2.  Report to be conducted per Sections 1803.3 through 1803.5.  Completed report shall comply with Section 1803.6.  Report shall be signed and sealed by a Florida licensed professional engineer in accordance with F.S. 471.025 and Florida Administrative Code Sections 61G15-30.001 and 61G15-23.001 through .005. You can request a deferred submittal by providing a letter on company letterhead.
CUSVC COMPLETE 02/05/2026 02/13/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 02/05/2026 02/09/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/05/2026 02/06/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 02/05/2026 02/09/2026
LOCATE COMPLETE 02/05/2026 02/11/2026
Note: Released By: IVAN SANDERSON - -
MECH COMPLETE 02/05/2026 02/10/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 02/05/2026 02/11/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON HOLD 02/05/2026 02/11/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Floor plan: missing the sq footage of the covered patio include that on the plans

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
WATER- TURN ON ¤50.00 02/26/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/26/2026
INSPECTION - RESIDENTIAL ¤1,416.25 02/26/2026
PLAN REVIEW - RESIDENTIAL ¤401.70 02/26/2026
CONTRACTOR CHANGE ¤20.00 02/26/2026
FC IMPACT FEE EMS ¤62.00 02/26/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 02/26/2026
FC IMPACT FEE LIBRARY ¤268.00 02/26/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 02/26/2026
PEP TANK INSTALL ¤756.74 02/26/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 02/26/2026
RSI DRIVEWAY AFTER POUR ¤16.25 02/26/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 02/26/2026
RSI FIELD SURVEY INSPECTION ¤48.75 02/26/2026
RSI FORMBOARD REVIEW ¤16.25 02/26/2026
RSI PLAN REVIEW NEW ¤48.75 02/26/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 02/26/2026
RSI ROW FINAL INSPECTION ¤16.25 02/26/2026
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 02/26/2026
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 02/26/2026
SURCHARGE FS 533.721 ¤18.48 02/26/2026
SURCHARGE - FS 468.631 ¤27.72 02/26/2026
SW ENG RES REVIEW 240 ¤240.00 02/26/2026
WATER METER W/ TAP ¤2,326.93 02/26/2026
TRANSP RES IMPACT FEE 10-25 ¤10,258.17 02/26/2026
SEWER CREDIT (¤1,342.00) 02/26/2026
WASTEWATER PERM INSPECTION ¤80.00 02/26/2026
WASTEWATER PERM REVIEW ¤25.00 02/26/2026
SEWER CAPITAL FACILITY ¤4,415.00 02/26/2026
WATER CAPITAL FACILITY FEE ¤3,790.49 02/26/2026
WATER PERMIT REVIEW ¤25.00 02/26/2026
WATER MAIN EXTENSION IMPACT ¤917.27 02/26/2026
SITE PLAN 30 ¤30.00 02/26/2026
Fees Total Due: ¤0.00 Total Paid: ¤36,203.25