I want to search for...

Permit #2005010011

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00020-0240
CONDITIONED SPACE: 2424 sqft
GARAGE: 487 sqft
OPENED PORCH (WITH ROOF) : 108 sqft
SCREEN PORCH (SOLID ROOF) : 217 sqft
Total Square Footage: 3236 sqft
Block: 0002
Subdivision: -
Job Phone: (386) 788-0820
Location Address: 102 WHISPERING PINE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/07/2005
NOC: RECORDED
Applicant name: MOJI BABAZADEH
Owner: KIKOS HARRY E & VANA

Address

2029 MANOR LANE

PARK RIDGE, IL 60068

Lot: 240
Contracted Stated Job Value: ¤164,847.00
Job Description: SINGLE-FAMILY RESIDENCE
Type: CN

Contractor

INTERVEST CONSTRUCTION, INC.
Status Location Address State License Number Phone Fax
CANCEL

2379 BEVILLE ROAD

Daytona Beach, FL 32119

CBC044682 (Exp: 08/31/2018) (386)236-4133 (386)763-7833

Sub Contractors

BARRY D MARTIN
Status Location Address State License Number Phone Fax
CANCEL

1650 N STATE STREET

Bunnell, FL 32110

CCC033728 (Exp: 08/31/2020) (386) 437-7700 (386)437-7701
KATRINA ELAINE RIEF-D'ERRICO
Status Location Address State License Number Phone
CANCEL

157 BOULDER ROCK DR

Palm Coast, FL 32137

CFC1425676 (Exp: 09/30/2008) (386)437-4250
MICHAEL G MORELLO JR
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32137

CAC014293 (Exp: 08/31/2014) (386)447-3950 (386)446-4614

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 03/23/2006 FINAL APPROVED JLEVRAULT
ENGINEERING FINAL 03/15/2006 APPROVED BFCHAMBERLAIN
Note: THIS IS A REINSPECTION
ENGINEERING FINAL 02/23/2006 Disapproved -FEE REQUIRED BFCHAMBERLAIN
Note: remove trash/debris from rear and rear bank and right side
UTILITY COMPANY FINAL 02/22/2006 APPROVED RANDRADE
RESIDENTIAL EARLY POWER 02/15/2006 APPROVED ARITTER
DRIVEWAY 01/27/2006 APPROVED BFCHAMBERLAIN
INSULATION INSPECTION 11/09/2005 APPROVED - AS NOTED ARAYMOND
Note: 1. SMOKE DETECTOR MUST BE MINIMUM OF 36" FROM KITCHEN. 2. DINING OUTLET NEC 210.52-B-2 CANNOT BE ON SMALL APPLIANCE CICUIT.
ALL ROUGH 11/02/2005 APPROVED ARITTER
Note: THIS IS A REINSPECTION
ALL ROUGH 11/01/2005 CANCELLED BY APPLICANT LMUSGROVE
Note: THIS IS A REINSPECTION
ALL ROUGH 10/19/2005 Disapproved -FEE REQUIRED ARAYMOND
Note: 1. FIRE STOP ELECTRIC WIRING AT COLUMN IN KITCHEN AT PENINSULA. 2. SMOKE DETECTOR MUST BE MINIMUM OF 36" AWAY FROM KITCHEN AND BATH. 3. A/C DUCT MUST ALLOW FOR R=30 INSULATION IN BEDROOM. 4. LAUNDRY DRYER VENT MUST NOT HAVE COMBUSTABLE WITHIN 1". 5. ELECTRICAL PLAN 'E.1' MISSING IN CONST. DOC'S. NOT READY.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/07/2005 APPROVED JLEVRAULT
LINTEL 08/02/2005 APPROVED MMOORE
Note: THIS IS A REINSPECTION
LINTEL 07/29/2005 Disapproved -FEE REQUIRED MMOORE
Note: ONE BAR/DOWEL MISSING/SEE PLANS
LINTEL 07/28/2005 Disapproved -FEE REQUIRED MMOORE
Note: 6 rebar either missing dowel or not tied. See plans
MONOLITHIC SLAB INSPECTION/SLAB 07/12/2005 APPROVED - AS NOTED MMOORE
Note: 2 DOWELS MISSING/ MARKED ON PLAN
FIRST ROUGH PLUMBING INSPECTION 07/08/2005 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
FIRST ROUGH PLUMBING INSPECTION 07/05/2005 CANCELLED BY APPLICANT ECOYNE
Note: cancelled by applicant/ may have inputted wrong inspection needed temp pole ecoyne
TEMPORARY POLE 07/05/2005 APPROVED MMORATTO
Note: called FPL on 7-6-05 spoke w/susan to request temp. pole LMusgrove

Review History

Department Status Date In Date Out
BLD CANCEL 11/14/2005
ZON COMPLETE 05/10/2005 05/10/2005
Note: Released By: HHERKERT
BLD COMPLETE 05/10/2005 06/03/2005
Note: Released By: LWOODROME Released By: LWOODROME Held on 5-13-05 for bond beam transition detail. L Woodrome 6-3-05 Approved for release as noted on plan cover sheet.
ENG COMPLETE 01/13/2005 01/13/2005
Note: Released By: MLUNDGREN
BLD COMPLETE 01/05/2005 02/02/2005
Note: Released By: LWOODROME 2-2-05 Approved for release as noted on plan cover sheet. Reviewed by JH released by LW
DSD COMPLETE 01/05/2005
Note: Released By: JCALVERT Released By: JCALVERT for MW
LDS COMPLETE 01/11/2005
Note: Released By: CGOEWEY Held By: CGOEWEY Held By: CGOEWEY 1/10/05 (DD) BARRICADES REQUIRED

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 03/28/2006
REINSPECTION FEE ¤40.00 03/28/2006
REINSPECTION FEE ¤40.00 03/28/2006
REINSPECTION FEE ¤40.00 03/28/2006
STORMWATER REINSPECTION FEE ¤35.00 03/28/2006
REVISION ¤40.00 06/06/2005
ADMIN FEE ¤20.00 02/07/2005
BUILDING CODE ADMIN FUND ¤16.18 02/07/2005
ELECTRIC FEE ¤129.00 02/07/2005
ENGINEERING PERMIT FEES ¤80.00 02/07/2005
FIRE RES IMPACT FEE 4-1-04 ¤168.91 02/07/2005
MECHANICAL FEE ¤129.00 02/07/2005
PERMIT FEE ¤643.50 02/07/2005
PARKS IMPACT FEE 11-2-04 ¤1,120.91 02/07/2005
PLAN CHECK FEE ¤66.00 02/07/2005
PLUMBING FEE ¤129.00 02/07/2005
RADON FEE ¤16.18 02/07/2005
TRANSPORTATION IMPACT FEE3/RES ¤2,885.00 02/07/2005
Fees Total Due: ¤0.00 Total Paid: ¤5,638.68