| Parcel Id: 07-11-31-7035-00570-0070 |
| CONDITIONED SPACE: 2720 sqft |
| CONDITIONED SPACE: 839 sqft |
| GARAGE: 482 sqft |
| SCREEN PORCH (SOLID ROOF) : 185 sqft |
| OPENED PORCH (WITH ROOF) : 71 sqft |
| OPENED PORCH (WITH ROOF) : 36 sqft |
| Total Square Footage: 4333 sqft |
| Block: 57 |
| Subdivision: - |
| Job Phone: (386)246-6328 |
| Location Address: 18 BUNKER HILL DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/11/2005 |
| NOC: RECORDED |
| Applicant name: EUGENE THOMAS |
| Owner: KLOTSMAN ARTUR |
| Lot: 7 |
| Contracted Stated Job Value: ¤210,000.00 |
| Job Description: SINGLE-FAMILY RESIDENCE |
| Type: CN |
| Type |
Request Date |
Result |
Inspector |
|
FINAL COMPLETE BUILDING INSPECTION |
07/13/2006 |
FINAL APPROVED |
PGALLMANN |
|
Note: THIS IS A REINSPECTION
|
|
FINAL COMPLETE BUILDING INSPECTION |
07/11/2006 |
CANCELLED BY APPLICANT |
PGALLMANN |
|
Note: THIS IS A REINSPECTION
|
|
FINAL COMPLETE BUILDING INSPECTION |
06/19/2006 |
Disapproved -FEE REQUIRED |
MMOORE |
|
Note: 1. dish washer hammer arrestor missing 2. termite sticker at electric panel 3. suite #1 & #2, bathrooms not built per plan
|
|
STORMWATER FINAL INSPECTION |
06/15/2006 |
APPROVED |
BFCHAMBERLAIN |
|
UTILITY COMPANY FINAL |
05/23/2006 |
APPROVED |
TSCHWEERS |
|
Note: THIS IS A REINSPECTION
|
|
UTILITY COMPANY FINAL |
05/16/2006 |
Disapproved - NO FEE |
RANDRADE |
|
Note: PEP TANK IS 3" OFF SIDE OF DRIVEWAY AND DEPRESSION IS STARTING TO FORM AROUND TANK LID
|
|
DRIVEWAY |
04/20/2006 |
APPROVED |
BFCHAMBERLAIN |
|
INSULATION INSPECTION |
03/27/2006 |
APPROVED |
ARITTER |
|
Note: THIS IS A REINSPECTION
|
|
INSULATION INSPECTION |
03/23/2006 |
Disapproved -FEE REQUIRED |
JLEVRAULT |
|
Note: BLOCKERS MISSING ABOVE REAR DOOR AT FIRST FLOOR LEVEL. REMOVE PAPER FROM INSULATION TOUCHING DRYER EXHAUST VENT.
|
|
ALL ROUGH |
03/21/2006 |
APPROVED |
JLEVRAULT |
|
Note: THIS IS A REINSPECTION
|
|
ALL ROUGH |
03/20/2006 |
CANCELLED BY APPLICANT |
JLEVRAULT |
|
Note: THIS IS A REINSPECTION
|
|
ALL ROUGH |
03/17/2006 |
CANCELLED BY APPLICANT |
JLEVRAULT |
|
Note: THIS IS A REINSPECTION
|
|
ALL ROUGH |
03/14/2006 |
Disapproved -FEE REQUIRED |
JLEVRAULT |
|
Note: THIS IS A REINSPECTION NO WIRE NUTS AND PIGTAILS ON ALL SWITCH BOXES. NEED DETAIL FOR TRUSSES TO DOUBLE LVL BEHIND STAIRS. PROVIDE STEEL STAIR DETAILS.
|
|
ALL ROUGH |
02/02/2006 |
Disapproved -FEE REQUIRED |
JLEVRAULT |
|
Note: THIS IS A REINSPECTION STUCCO HAS BEEN COMPLETED WITH NO LATH INSPECTION.!!!!!!!!!!!!!! sTILL NO WIRE NUTS ON SWITCH BOX GROUNDS. KITCHEN EXHAUST DUCT STILL RUN IN ROOF VENT. INTERIOR MAIN STAIRS STILL NOT TO CODE. TUBS STILL NOT PROPERLY SECURED. PROVIDE METAL STAIR PLANS AND DETAILS. PROVIDE DETAIL FOR TRUSS REPAIR (3) THAT TIE INTO DOUBLE LVL.
COME IN FOR MEETING FIRST THING IN THE MORNING PLEASE.
|
|
GAS ROUGH |
01/31/2006 |
APPROVED |
ARITTER |
|
ALL ROUGH |
01/27/2006 |
Disapproved -FEE REQUIRED |
MMOORE |
|
Note: THIS IS A REINSPECTION 1. NEED METAL STAIR DETAIL 2. ITEMS NOT FINISHED FROM LAST NON-COMPLIANCE DATED 1-2-06
|
|
ALL ROUGH |
01/20/2006 |
Disapproved -FEE REQUIRED |
JLEVRAULT |
|
Note: GAS INSPECTION REQUIRED BEFORE ALL ROUGH. MISSING WIRE NUTS ON GROUNDS IN TWO-GANG SWITCH BOXES. KITCHEN EXHAUST DUCT RUN IN ROOF VENT - VENT SEPARATELY. SEWER CLEANOUT IN MIDDLE OF GARAGE DOOR IN DRIVEWAY. SMOKE DETECTOR BOXES, DUCTWORK, AND LIGHT BOXES ABOVE CEILING PLANE. TUBS NEED TO BE ANCHORED BETTER. SECOND FLOOR STAIRS NOT TO CODE.FIRST FLOOR STAIR LANDING NOT TO CODE OR PLAN - PROVIDE REVISION TO PLANS DEPT.BOTH SECOND FLOOR EXTERIOR DOORS ARE 13' 6" TO GRADE PROVIDE REVISED PLAN AND BUILD BEFORE CALLING FOR NEXT ALL ROUGH.
|
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
09/06/2005 |
APPROVED |
ARITTER |
|
Note: THIS IS A REINSPECTION
|
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
08/29/2005 |
Disapproved -FEE REQUIRED |
MMOORE |
|
Note: 1. GARAGE EXTERIOR STRAPS NOT LONG ENOUGH ON RIGHT 2. TO BE NAILED TO STUDS 3. NOT COMPLETE SET OF PLANS/ MISSING PAGE 9 AND DETAIL FOR HEADER STRAPPING
|
|
LINTEL |
06/01/2005 |
APPROVED |
MMOORE |
|
MONOLITHIC SLAB INSPECTION/SLAB |
04/28/2005 |
APPROVED |
MMOORE |
|
FOOTER |
03/17/2005 |
APPROVED |
JHINDMAN |
|
Note: THIS IS A REINSPECTION
|
|
FOOTER |
03/16/2005 |
Disapproved -FEE REQUIRED |
JHINDMAN |
|
Note: revised plan, many dowels missing or not per layout. clean out caved in footings.
|
|
MONOLITHIC SLAB INSPECTION/SLAB |
02/18/2005 |
APPROVED |
JHINDMAN |
|
MONOLITHIC SLAB INSPECTION/SLAB |
02/16/2005 |
Disapproved -FEE REQUIRED |
PMCMAHON |
|
FIRST ROUGH PLUMBING INSPECTION |
02/10/2005 |
APPROVED |
PMCMAHON |
| Department |
Status |
Date In |
Date Out |
|
ZON |
COMPLETE |
07/11/2006 |
07/11/2006 |
| Note: Released By: HHERKERT
|
|
BLD |
COMPLETE |
07/11/2006 |
07/11/2006 |
| Note: Released By: LWOODROME
Revision: Reconfigure bonus rooms |
|
ZON |
HOLD |
06/28/2006 |
06/28/2006 |
| Note: Held By: HHERKERT
copy of recorded "Single Family Affidavitt" is required. |
|
BLD |
CANCEL |
06/27/2006 |
|
|
SW1 |
COMPLETE |
04/12/2006 |
04/20/2006 |
| Note: Released By: LAPTEKAR
adding a circular driveway...site plan indicates 7.76' clearance from fire hydrant |
|
BLD |
COMPLETE |
03/16/2006 |
03/20/2006 |
| Note: Released By: LWOODROME
Revision: Shim out LVL @ truss hangers |
|
BLD |
COMPLETE |
02/22/2006 |
02/23/2006 |
| Note: Released By: LWOODROME
Reviusion; Stair detail |
|
BLD |
COMPLETE |
02/13/2006 |
02/14/2006 |
| Note: Released By: LWOODROME
Revision: Cut notch into LVL |
|
BLD |
COMPLETE |
01/27/2006 |
01/31/2006 |
| Note: Released By: LWOODROME
Revision: Stair detail
|
|
BLD |
COMPLETE |
02/24/2005 |
02/25/2005 |
| Note: Released By: LWOODROME
Held By: LWOODROME
2-25-05
Hold for exterior stair, handrail and guardrail details. Contacted GC. Met in office with
contractors rep.
LW
3-10-05
revisions received. Approved for release as noted on plan cover sheet. |
|
DSD |
COMPLETE |
|
01/11/2005 |
| Note: Released By: BBEMBRY
Released By: JCALVERT
Held By: MWALLENBERG
Held By: MPULASKI
Held By: JCALVERT
Held By: JCALVERT
Held By: JCALVERT
3 each Kitchens
need Sealed sitre plan
7/6/04 submitted revisions
9/27/04
Site plan does not match floor plan - the structural delineation on the site plan is
different from that of the floor plan.
Need sealed site plan
2nd floor bonus room #2 shows a 2nd kitchen - per LDC, unallowable to have 2 or more
kitchen in a R-1B zone. |