I want to search for...
Permit #2005010787
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-01040-0120 |
| CONDITIONED SPACE: 2110 sqft |
| GARAGE: 475 sqft |
| GARAGE: 86 sqft |
| OPENED PORCH (WITH ROOF) : 123 sqft |
| SCREEN PORCH (SOLID ROOF) : 358 sqft |
| Total Square Footage: 3152 sqft |
| Block: 0104 |
| Subdivision: - |
| Job Phone: (386)447-4400 |
| Location Address: 29 LOUISBURG LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/09/2005 |
| NOC: RECORDED |
| Applicant name: DAVID PAUL CROCKETT |
| Owner: WILLIAM SMITH & MARY SMITH |
|
Address 18 SAN ROAD PALM COAST, FL 32137 |
| Lot: 120 |
| Contracted Stated Job Value: ¤270,000.00 |
| Job Description: SINGLE-FAMILY RESIDENCE |
| Type: CN |
Contractor
THE WATERSIDE GROUP, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
17-B BRELYN PLACE PALM COAST, FL 32137 |
RG0041345 (Exp: 08/31/2010) | (386)447-4400 | (386)447-5800 |
Sub Contractors
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 1009 BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2014) | (386) 931-2568 | 386-313-3445 |
LARRY MILTON HISS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1315 A LPGA BLVD Holly Hill, FL 32117 |
CAC032450 (Exp: 08/31/2018) | (386) 672-8688 | (386)238-8688 |
MARTIN JOHN EVANS
| Status | Location Address | State License Number |
| ACTIVE |
14 FORT CAROLINE CT BUNNELL, FL 32110 |
CFC057676 (Exp: 08/31/2026) |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 12/14/2005 | FINAL APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 12/13/2005 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: Unable to test smoke detectors. Remove Factcal panel. ory seal. No termite sticker on electrical panel. No insulation cert. | |||
| UTILITY COMPANY FINAL | 12/08/2005 | APPROVED | RZALESKI |
| UTILITY COMPANY FINAL | 12/06/2005 | APPROVED - AS NOTED | RZALESKI |
| Note: Back charge due to missing meter pit lid and meter position being altered making the meter inaccessable for maintenance | |||
| ENGINEERING FINAL | 12/05/2005 | APPROVED | FTORO |
| Note: 0 road damages | |||
| ENGINEERING FINAL | 12/01/2005 | CANCELLED BY INSPECTOR | LAPTEKAR |
| Note: this inspection is sceduled already for 12/1 with a stormwater final | |||
| STORMWATER FINAL INSPECTION | 11/30/2005 | Disapproved -FEE REQUIRED | FTORO |
| Note: road damages cut but not repaired clean up street of all loose sand | |||
| PRE DRIVEWAY | 11/15/2005 | APPROVED | FTORO |
| Note: THIS IS A REINSPECTION | |||
| PRE DRIVEWAY | 11/10/2005 | Disapproved -FEE REQUIRED | DSCHRAGER |
| Note: not framed | |||
| INSULATION INSPECTION | 08/02/2005 | APPROVED | MMOORE |
| ALL ROUGH | 07/28/2005 | APPROVED | ARAYMOND |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/01/2005 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 06/29/2005 | Disapproved -FEE REQUIRED | MMOORE |
| Note: GROUT UNDER TRUSSES...2-PLY HUS26 SIMPSON HANGER MTT28B BOLT ISN'T LONG ENOUGH TO HOLD ANYTHING. ARCHED FRAMING ABOVE ENTRY NEEDS TAOCONS SEE PAGE 6/6 IN PLANS, TRUSS B-6 IS TO BE A 2 PLY TRUSS AND NEEDS TO BE NAILED TOGETHER, TRUSS STRAPPING AT THE PORCH-END/OVER COLUMN FOR TRUSS B-6 NOT WRAPPED OVER AND NAILED OFF. END OF SHEAR WALL IN FAMILYROOM NOT BOLTED TO CMU. TRUSS A-14 MISSING ENGINEERING. CHECK ALL TRUSS ENGINEERING FOR REINSPECTION. | |||
| LINTEL | 04/08/2005 | APPROVED | DROCKWELL |
| TEMPORARY POLE | 03/28/2005 | APPROVED | JHINDMAN |
| Note: spoke with susan at FPL on 3-29-05 for request of temp. pole. LMusgrove | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 03/14/2005 | APPROVED | JHINDMAN |
| MONOLITHIC SLAB INSPECTION/SLAB | 03/11/2005 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: 5 dowel rods missing, copper waterline exposed through footer and needs to be sleaved. | |||
| FIRST ROUGH PLUMBING INSPECTION | 03/04/2005 | APPROVED | JHINDMAN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/25/2005 | 02/02/2005 |
| Note: Released By: JHINDMAN 2-2-05 approved for release as noted on the plan cover sheet. checked by D.R. reviewed by J.H. | |||
| DSD | COMPLETE | 01/27/2005 | |
| Note: Released By: JCALVERT | |||
| ENG | COMPLETE | 02/07/2005 | |
| Note: Released By: MLUNDGREN | |||
| LDS | COMPLETE | 02/07/2005 | |
| Note: Released By: CGOEWEY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 12/15/2005 |
| REINSPECTION FEE | ¤40.00 | 12/15/2005 |
| REINSPECTION FEE | ¤40.00 | 12/15/2005 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 12/15/2005 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 12/15/2005 |
| UTILITIES DAMAGE BACKCHARGE | ¤79.40 | 12/15/2005 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 02/09/2005 |
| ADMIN FEE | ¤20.00 | 02/09/2005 |
| BUILDING CODE ADMIN FUND | ¤15.76 | 02/09/2005 |
| ELECTRIC FEE | ¤192.00 | 02/09/2005 |
| ENGINEERING PERMIT FEES | ¤80.00 | 02/09/2005 |
| FIRE RES IMPACT FEE 4-1-04 | ¤168.91 | 02/09/2005 |
| MECHANICAL FEE | ¤192.00 | 02/09/2005 |
| PERMIT FEE | ¤1,053.00 | 02/09/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 02/09/2005 |
| PLAN CHECK FEE | ¤108.00 | 02/09/2005 |
| PLUMBING FEE | ¤192.00 | 02/09/2005 |
| RADON FEE | ¤15.76 | 02/09/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤6,312.74 |