I want to search for...
Permit #2005010815
Permit Details
Status: COED
| Parcel Id: 07-11-31-7013-00070-0250 |
| CONDITIONED SPACE: 1564 sqft |
| GARAGE: 440 sqft |
| SCREEN PORCH (SOLID ROOF) : 160 sqft |
| OPENED PORCH (WITH ROOF) : 40 sqft |
| Total Square Footage: 2204 sqft |
| Block: 0007 |
| Subdivision: - |
| Job Phone: (386)447-0836 |
| Location Address: 114 BREEZE HILL LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/18/2005 |
| NOC: RECORDED |
| Applicant name: ANTONIO AMARAL JR |
| Owner: AMARAL CUSTOM HOMES, INC |
|
Address 13 UTILITY DRIVE PALM COAST, FL 32137 |
| Lot: 250 |
| Contracted Stated Job Value: ¤110,900.00 |
| Job Description: SINGLE-FAMILY RESIDENCE |
| Type: CN |
Contractor
WORLD CLASS HOMES OF NE FLORIDA INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
13 UTILITY DR PALM COAST, FL 32137 |
RR282811317 (Exp: 08/31/2011) | (386)447-0836 | (386)447-7959 |
Sub Contractors
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 1009 BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2014) | (386) 931-2568 | 386-313-3445 |
THOMAS ALAN MOSE
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO BOX 1894 HOLLY HILL, FL 32117 |
CAC048082 (Exp: 08/31/2026) | 386-255-4545 | (386)252-4979 |
JAMES JOSEPH SAVNIK JR
| Status | Location Address | State License Number | Phone |
| CANCEL |
1120 COUNTY RD 305 BUNNELL, 32110 |
CPC057381 (Exp: 09/30/2008) | (386) 445-1253 |
ANTONIO JR AMARAL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
13 Utility Drive PALM COAST, FL 32137 |
CCC058004 (Exp: 08/31/2018) | (386)445-9393 | (386)446-0403 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 02/10/2006 | FINAL APPROVED | MMOORE |
| ENGINEERING FINAL | 02/01/2006 | APPROVED | BFCHAMBERLAIN |
| UTILITY COMPANY FINAL | 01/18/2006 | APPROVED | RANDRADE |
| DRIVEWAY | 11/28/2005 | APPROVED | FTORO |
| INSULATION INSPECTION | 10/10/2005 | APPROVED | MMOORE |
| ALL ROUGH | 10/04/2005 | APPROVED | JLEVRAULT |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/17/2005 | APPROVED - AS NOTED | MMOORE |
| Note: THIS IS A REINSPECTION...HAVE A VAPOR BARRIER AT SLIDER WALL FOR ALL-ROUGH INSPECTION/ UNDER ALL FRAMING ON TOP OF CONCRETE | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/15/2005 | Disapproved -FEE REQUIRED | MMOORE |
| Note: THIS IS A REINSPECTION....1. GROUTING NOT COMPLETED/ LIQUID GROUT THAT FLOWS UNDER A TRUSS AND DOES NOT FILL THE SPACE BETWEEN TRUSS AND LINTEL IS NOT ACCEPTABLE 2. SOME ARE OK AND MOST ARE NOT GROUTED CORRECTLY 3. NON-TREATED WOOD AT LINTEL OVER SLIDER NEEDS VAPOR BARRIER | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/28/2005 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. GROUT UNDER TRUSSES 2. ENTRYWAY/ JACKS/ TRUSSES MISSING STRAPS AT LINTELS 3. TRUSS T09 AT FRONT ENTRY/ NEED TO EXPOSE HANGER COVERED WITH INSULATION FOR VIEWING TO SEE HANGER 4. ENTRY/ INSIDE FRONT DOOR/ ABOVE RIGHT/ KNEE WALL NOT SUPPORTED/ ONLY RESTING ON PLYWOOD/ NOT STRAPPED/ FRAME OVER STRAP TRUSS T-13 NOT NAILED CORRECTLY 5. ENTRY/ SAME AREA ON LEFT/ KNEEWALL NOT BLOCKED UNDER PLYWOOD OR STRAPPED 6. TRUSS T-14 AT NOOK WINDOW/ ABOVE/ EXPOSE ADDED STRAP TO SEE TAPCONS 7. HIP HJ7 GARAGE/ ON RIGHT/ NOT STRAPPED 8. ENTRY RIDGE BETWEEN TRUSS T-10 AND T-11. NEEDS BETTER BLOCKING AT END PLUS STRAP 9. VALLEYS AT SAME AREA BOTH/ BETTER BLOCKING 10. ENGINEERING/ T-BACKS OR STIFF BACKS/ TO BE NAILED 6" OC | |||
| DOWN CELL | 06/03/2005 | CANCELLED BY INSPECTOR | MMOORE |
| Note: contractor called in wrong inspection should be a lintel | |||
| LINTEL | 06/03/2005 | APPROVED | MMOORE |
| MONOLITHIC SLAB INSPECTION/SLAB | 05/13/2005 | APPROVED | ARAYMOND |
| FIRST ROUGH PLUMBING INSPECTION | 05/11/2005 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 05/10/2005 | Disapproved -FEE REQUIRED | MMOORE |
| Note: NO PLANS IN INSPECTIONS BOX. |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/27/2005 | 02/03/2005 |
| Note: Released By: LWOODROME 2-3-05 Approved for release as noted on plaqn cover sheet. Checked by FR released by LW | |||
| DSD | COMPLETE | 01/27/2005 | |
| Note: Released By: JCALVERT | |||
| ENG | COMPLETE | 02/07/2005 | |
| Note: Released By: MLUNDGREN | |||
| LDS | COMPLETE | 02/02/2005 | |
| Note: Released By: CGOEWEY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 02/27/2006 |
| REINSPECTION FEE | ¤40.00 | 02/27/2006 |
| REINSPECTION FEE | ¤40.00 | 02/27/2006 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 02/18/2005 |
| ADMIN FEE | ¤20.00 | 02/18/2005 |
| BUILDING CODE ADMIN FUND | ¤11.02 | 02/18/2005 |
| ELECTRIC FEE | ¤106.20 | 02/18/2005 |
| ENGINEERING PERMIT FEES | ¤80.00 | 02/18/2005 |
| FIRE RES IMPACT FEE 4-1-04 | ¤168.91 | 02/18/2005 |
| MECHANICAL FEE | ¤106.20 | 02/18/2005 |
| PERMIT FEE | ¤495.30 | 02/18/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 02/18/2005 |
| PLAN CHECK FEE | ¤50.80 | 02/18/2005 |
| PLUMBING FEE | ¤106.20 | 02/18/2005 |
| RADON FEE | ¤11.02 | 02/18/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤5,281.56 |