I want to search for...
Permit #2005010880
Permit Details
Status: COED
| Parcel Id: 07-11-31-7012-00160-0380 |
| CONDITIONED SPACE: 356 sqft |
| CONDITIONED SPACE: 2474 sqft |
| GARAGE: 555 sqft |
| OPENED PORCH (WITH ROOF) : 108 sqft |
| SCREEN PORCH (SOLID ROOF) : 217 sqft |
| Total Square Footage: 3710 sqft |
| Block: 16 |
| Subdivision: - |
| Job Phone: (386)447-5225 |
| Location Address: 14 BASSETT LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/11/2005 |
| NOC: RECORDED |
| Applicant name: MOJI BABAZADEH |
| Owner: INTERVEST CONSTRUCTION |
|
Address 2359 BEVILLE ROAD DAYTONA BEACH, FL 32119 |
| Lot: 38 |
| Contracted Stated Job Value: ¤147,160.00 |
| Job Description: SINGLE-FAMILY RESIDENCE |
| Type: CN |
Contractor
INTERVEST CONSTRUCTION, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2379 BEVILLE ROAD Daytona Beach, FL 32119 |
CBC044682 (Exp: 08/31/2018) | (386)236-4133 | (386)763-7833 |
Sub Contractors
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 1009 BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2014) | (386) 931-2568 | 386-313-3445 |
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
KATRINA ELAINE RIEF-D'ERRICO
| Status | Location Address | State License Number | Phone |
| CANCEL |
157 BOULDER ROCK DR Palm Coast, FL 32137 |
CFC1425676 (Exp: 09/30/2008) | (386)437-4250 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 02/15/2006 | FINAL APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 02/13/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. HOUSE LOCKED 2. NO PLANS 3. NO TERMITE STICKER IN ELECTRIC PANEL BOX | |||
| ENGINEERING FINAL | 02/09/2006 | APPROVED | BFCHAMBERLAIN |
| ENGINEERING FINAL | 02/01/2006 | Disapproved -FEE REQUIRED | BFCHAMBERLAIN |
| Note: fill and sod on rear fence remove debris from rear porch | |||
| UTILITY COMPANY FINAL | 01/19/2006 | APPROVED | RANDRADE |
| RESIDENTIAL EARLY POWER | 12/07/2005 | APPROVED | JLEVRAULT |
| DRIVEWAY | 12/05/2005 | APPROVED | FTORO |
| PRE DRIVEWAY | 11/23/2005 | CANCELLED BY APPLICANT | BFCHAMBERLAIN |
| INSULATION INSPECTION | 10/04/2005 | APPROVED | MMOORE |
| ALL ROUGH | 09/27/2005 | APPROVED | ARITTER |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 09/26/2005 | Disapproved -FEE REQUIRED | ARITTER |
| Note: 1. EXHAUST FAN DUCT NOT CONNECTED IN BATER #2. 2. BLOCK RIDGE 2 PLACES BACK AT GABLE BONUS ROOM. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/16/2005 | APPROVED | ARAYMOND |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/12/2005 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. MASTER BATH/ MISSING R & L LEDGERS/ NAIL TRUSSES FROM OUTSIDE 2. BOLT UPPER JACUZZI WALLS/ L&R 2 BOLTS PER SIDE 3. BOLT AT BEDROOM #2 SHEAR WALL/ LEFT OF DOOR 4. LEDGER MISSING BEDROOM #4 5. NOOK WINDOW CORNRER/ STRAPS NOT NAILED | |||
| LINTEL | 07/13/2005 | APPROVED | MMOORE |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 06/27/2005 | APPROVED | MBRENNAN |
| MONOLITHIC SLAB INSPECTION/SLAB | 05/27/2005 | APPROVED | MMOORE |
| Note: ONE DOWEL MISSING/ MARKED ON PLANS IN YELLOW. INSTALL BEFORE POUR | |||
| FIRST ROUGH PLUMBING INSPECTION | 05/26/2005 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| FIRST ROUGH PLUMBING INSPECTION | 05/25/2005 | Disapproved -FEE REQUIRED | ARITTER |
| Note: PAD CROSSINGS OF WATER LINESWITH ARMAFLEX |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/27/2005 | 02/10/2005 |
| Note: Released By: JHINDMAN 2-10-05 approved for release as noted on the plan cover sheet. checked by D.R. reviwed by J.H. | |||
| DSD | COMPLETE | 01/28/2005 | |
| Note: Released By: JCALVERT | |||
| ENG | COMPLETE | 02/03/2005 | |
| Note: Released By: MLUNDGREN | |||
| LDS | COMPLETE | 02/07/2005 | |
| Note: Released By: CGOEWEY | |||
| BLD | COMPLETE | 05/02/2005 | |
| Note: Released By: LWOODROME 5-2-05 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 02/17/2006 |
| REINSPECTION FEE | ¤40.00 | 02/17/2006 |
| REINSPECTION FEE | ¤40.00 | 02/17/2006 |
| REINSPECTION FEE | ¤40.00 | 02/17/2006 |
| REINSPECTION FEE | ¤40.00 | 02/17/2006 |
| REVISION | ¤40.00 | 02/17/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 02/17/2006 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 02/11/2005 |
| ADMIN FEE | ¤20.00 | 02/11/2005 |
| BUILDING CODE ADMIN FUND | ¤18.55 | 02/11/2005 |
| ELECTRIC FEE | ¤161.40 | 02/11/2005 |
| ENGINEERING PERMIT FEES | ¤80.00 | 02/11/2005 |
| FIRE RES IMPACT FEE 4-1-04 | ¤168.91 | 02/11/2005 |
| MECHANICAL FEE | ¤161.40 | 02/11/2005 |
| PERMIT FEE | ¤854.10 | 02/11/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 02/11/2005 |
| PLAN CHECK FEE | ¤87.60 | 02/11/2005 |
| PLUMBING FEE | ¤161.40 | 02/11/2005 |
| RADON FEE | ¤18.55 | 02/11/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤6,012.82 |