I want to search for...
Permit #2005020179
Permit Details
Status: COED
| Parcel Id: 07-11-31-7016-00120-1280 |
| CONDITIONED SPACE: 2233 sqft |
| CONDITIONED SPACE: 859 sqft |
| SCREEN PORCH (SOLID ROOF) : 74 sqft |
| SCREEN PORCH (SOLID ROOF) : 372 sqft |
| GARAGE: 560 sqft |
| OPENED PORCH (WITH ROOF) : 76 sqft |
| Total Square Footage: 4174 sqft |
| Block: 0012 |
| Subdivision: - |
| Job Phone: (386)447-4400 |
| Location Address: 14 CURTIS CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/04/2005 |
| NOC: RECORDED |
| Applicant name: DAVID P CROCKETT |
| Owner: PATRICIA AND EMMA SHANAHAN |
|
Address 85 LAKE DRIVE NEW MILFORD, CT 06776 |
| Lot: 280 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: SINGLE-FAMILY RESIDENCE |
| Type: CN |
Contractor
THE WATERSIDE GROUP, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
17-B BRELYN PLACE PALM COAST, FL 32137 |
RG0041345 (Exp: 08/31/2010) | (386)447-4400 | (386)447-5800 |
Sub Contractors
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 1009 BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2014) | (386) 931-2568 | 386-313-3445 |
GREGORY MICHAEL SCHULER
| Status | Location Address | State License Number | Phone |
| DECEASED |
5275 US 1 South St. Augustine, FL 32086 |
CAC046191 (Exp: 08/31/2018) | (386) 797-5353 |
MARTIN JOHN EVANS
| Status | Location Address | State License Number |
| ACTIVE |
14 FORT CAROLINE CT BUNNELL, FL 32110 |
CFC057676 (Exp: 08/31/2026) |
DAVID PAUL CROCKETT
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
17-B BRELYN PLACE PALM COAST, FL 32137 |
RG0041345 (Exp: 08/31/2010) | (386)447-4400 | (386)447-5800 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 08/29/2006 | FINAL APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 08/28/2006 | Disapproved -FEE REQUIRED | KSAMPICO |
| Note: Missing receptacles - kitchen kneewall, rear slider, and upstairs bath. Move smoke detectors away from 3' of ceiling fan wingtip. Spa pump not accessible. AHU not labeled for MOCP. Same AHU needs disconnect. Secure/ fasten cover. Seal ductwork into attic from upstairs AHU. Disconnect at A/C to be moved for 3' working clearance. Need arc shields at all kitchen receptacles above counter. Locate insulation certificate. | |||
| FINAL COMPLETE BUILDING INSPECTION | 08/24/2006 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: Access for spa motor not near motor. (Not even in view), several kitchen outlets hanging out of wall and not plated. Unable to locate 2nd grounding rod, a/c piping entering house should be sealed. | |||
| STORMWATER FINAL INSPECTION | 08/16/2006 | APPROVED | DRANDALL |
| Note: THIS IS A REINSPECTION 0 road damage | |||
| STORMWATER FINAL INSPECTION | 08/14/2006 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: THIS IS A REINSPECTION place sod in adj. property swale.....seed & straw area beyond new sod in adj. property swale where disturbed.....remove base materal for pavers in adj. property swale, regrade & sod..... | |||
| STORMWATER FINAL INSPECTION | 08/11/2006 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: repair runoff damage both left & right side of pool, regrade & resod.....remove pavers & trash from adj. property across street.....remove large pile of paver base materal same spot as discarded pavers | |||
| STORMWATER FINAL INSPECTION | 08/02/2006 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: complete sod left side of pool to contain runoff.....clean out culverts.....remove sod pallots from across street.....remove dirt pile from across street.....56 sf road damage | |||
| UTILITY COMPANY FINAL | 07/26/2006 | APPROVED | TSCHWEERS |
| PRE DRIVEWAY | 06/20/2006 | APPROVED | BFCHAMBERLAIN |
| Note: THIS IS A REINSPECTION | |||
| PRE DRIVEWAY | 06/02/2006 | Disapproved -FEE REQUIRED | BFCHAMBERLAIN |
| Note: Driveway not formed completely | |||
| INSULATION INSPECTION | 03/15/2006 | APPROVED | TOUTLAND |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 03/08/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: fire stop missing many areas, insulation missing on cmu's, need gas permit and rough inspection, tighten all loose hold dowm rods, outlet more than 36" from lav. bond copper pipe and valve to pump on spa in master bath, stairs not to code, canalievered landing not to plan | |||
| ALL ROUGH | 02/27/2006 | APPROVED - AS NOTED | ARAYMOND |
| Note: no gas permit, | |||
| ALL ROUGH | 02/22/2006 | CANCELLED BY INSPECTOR | ARAYMOND |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/21/2006 | CANCELLED BY APPLICANT | ARAYMOND |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/20/2006 | APPROVED - AS NOTED | ARAYMOND |
| Note: 1) BARRIER WALL AT DEN HAS INCOMPLETE LOAD PATH AT SILL SP1. 2) UPLIFT STRAPS MISSING AT F5, STAIRWAY SIDE. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/04/2006 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: ROOF & WALL SHEATHING OK FOR SHINGLES FILLED CELLS OK COMPLETE ALL THREE ,STRAPS AND BRACES AND RECALL PROVIDE ENGINEERING FOR FS | |||
| LINTEL | 11/07/2005 | APPROVED | JMCGOWEN |
| FIRST ROUGH PLUMBING INSPECTION | 10/21/2005 | CANCELLED BY INSPECTOR | JMCGOWEN |
| MONOLITHIC SLAB INSPECTION/SLAB | 10/21/2005 | APPROVED | JMCGOWEN |
| FIRST ROUGH PLUMBING INSPECTION | 10/13/2005 | APPROVED | JMCGOWEN |
| STEM FOOTING FOUNDATION | 08/29/2005 | APPROVED - AS NOTED | JMCGOWEN |
| Note: this inspection was picked up in the field by tony outland on 7/27/05 | |||
| TEMPORARY POLE | 03/23/2005 | APPROVED | JHINDMAN |
| Note: spoke with Susan at FPL on 3-23-05 for temp. pole - LMusgrove |
Review History
| Department | Status | Date In | Date Out |
| SW1 | HOLD | 06/16/2006 | 06/19/2006 |
| Note: Held By: LAPTEKAR Rejected By: LAPTEKAR Pavers need to be at least 2 3/8" for installation in the right of way. No edge restraint system shown. | |||
| BLD | COMPLETE | 03/09/2006 | 03/14/2006 |
| Note: Released By: LWOODROME Revision: Stair details | |||
| BLD | COMPLETE | 03/01/2006 | 03/02/2006 |
| Note: Released By: LWOODROME Revision: Connector @ 3 ply truss | |||
| BLD | COMPLETE | 02/24/2006 | 02/28/2006 |
| Note: Released By: LWOODROME Revision: Connector @ triple girder truss | |||
| BLD | COMPLETE | 12/30/2005 | 01/03/2006 |
| Note: Released By: LWOODROME Revision: Threaded tie rods, 135 degree wll detail, stair design | |||
| BLD | COMPLETE | 09/13/2005 | 09/16/2005 |
| Note: Released By: LWOODROME Revision: Stemwall | |||
| BLD | COMPLETE | 02/23/2005 | 02/25/2005 |
| Note: Released By: LWOODROME Held By: LWOODROME Held By: LWOODROME 2-25-05 Hold for floor truss layout or floor framing plan, not clear on provided plan. 3-3-05 Truss lay ou t provided. LW | |||
| DSD | COMPLETE | 02/08/2005 | |
| Note: Released By: JCALVERT Held By: JCALVERT Held By: JCALVERT Need a Sealed Survey Refered to Barbara Grossman because of rear dropoff 2/8 Ok per Barbara | |||
| ENG | COMPLETE | 02/18/2005 | |
| Note: Released By: LAPTEKAR Held By: LAPTEKAR need width of driveway at property line and at the road on the siote plan 2/21 new site plan | |||
| LDS | COMPLETE | 02/10/2005 | |
| Note: Released By: DWARD Held By: CGOEWEY Held By: CGOEWEY 2/9/05 (DD) TWO ROWS SILT FENCING TO PREVENT EROSION INTO CANAL, ONE AT HIGH WATER MARK | |||
| SW1 | COMPLETE | 06/21/2006 | |
| Note: Released By: WKINELL DW detail plans show 2 3/8" pavers and pavers as edge restraint.\\wk |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 08/29/2006 |
| REINSPECTION FEE | ¤40.00 | 08/29/2006 |
| REINSPECTION FEE | ¤40.00 | 08/29/2006 |
| REINSPECTION FEE | ¤40.00 | 08/29/2006 |
| REVISION | ¤40.00 | 08/29/2006 |
| REVISION | ¤40.00 | 08/29/2006 |
| REVISION | ¤40.00 | 08/29/2006 |
| REVISION | ¤40.00 | 08/29/2006 |
| REVISION | ¤40.00 | 08/29/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 08/29/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 08/29/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 08/29/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 08/29/2006 |
| SW REVISION | ¤40.00 | 08/29/2006 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 03/04/2005 |
| ADMIN FEE | ¤20.00 | 03/04/2005 |
| BUILDING CODE ADMIN FUND | ¤20.87 | 03/04/2005 |
| ELECTRIC FEE | ¤210.00 | 03/04/2005 |
| ENGINEERING PERMIT FEES | ¤80.00 | 03/04/2005 |
| FIRE RES IMPACT FEE 4-1-04 | ¤168.91 | 03/04/2005 |
| MECHANICAL FEE | ¤210.00 | 03/04/2005 |
| PERMIT FEE | ¤1,170.00 | 03/04/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 03/04/2005 |
| PLAN CHECK FEE | ¤120.00 | 03/04/2005 |
| PLUMBING FEE | ¤210.00 | 03/04/2005 |
| RADON FEE | ¤20.87 | 03/04/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤6,776.56 |