I want to search for...
Permit #2005030136
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-01490-0080 |
| CONDITIONED SPACE: 2057 sqft |
| GARAGE: 426 sqft |
| OPENED PORCH (WITH ROOF) : 50 sqft |
| SCREEN PORCH (SOLID ROOF) : 158 sqft |
| Total Square Footage: 2691 sqft |
| Block: 0149 |
| Subdivision: - |
| Job Phone: (386) 672-8285 |
| Location Address: 52 LEMA LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/15/2005 |
| NOC: RECORDED |
| Applicant name: Vanacore Construction Inc. (Residential Contractor |
| Owner: JANICE AND PATRICK MCMULLEN |
|
Address 232 WILDMERE ROAD ROCHESTER, NY 14617 |
| Lot: 080 |
| Contracted Stated Job Value: ¤135,000.00 |
| Job Description: SINGLE-FAMILY RESIDENCE |
| Type: CN |
Contractor
VANACORE CONSTRUCTION INC.
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
1451 N US HIGHWAY 1 Ormond Beach, FL 32174 |
SUITE 13 Ormond Beach, FL 32174 |
CBC058991 (Exp: 08/31/2024) | (386) 672-8285 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 09/28/2005 | FINAL APPROVED | ARITTER |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 09/27/2005 | Disapproved -FEE REQUIRED | ARITTER |
| Note: 1. NO ENERGY EFFICIENCY CARD POSTED BY HVAC CONTRACTOR- NO HVAC INSPECTION | |||
| ENGINEERING FINAL | 09/22/2005 | APPROVED | FTORO |
| Note: 37 S.F. ROAD DAMAGES $200 TYPE A ROAD | |||
| RESIDENTIAL EARLY POWER | 08/31/2005 | APPROVED | ARITTER |
| TEMPORARY POLE | 08/05/2005 | APPROVED | JMCGOWEN |
| DRIVEWAY | 07/28/2005 | APPROVED | FTORO |
| INSULATION INSPECTION | 06/17/2005 | APPROVED | MMOORE |
| DOWN CELL | 06/06/2005 | APPROVED | ARITTER |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 06/06/2005 | APPROVED - AS NOTED | ARITTER |
| Note: THIS IS A REINSPECTION 1. ITEM 1 ON LIST DATED 6-1-05 NOT DONE NO PRESSURE ON SECOND ROUGH OF PLUMBING CHECK @ INSULATION | |||
| DOWN CELL | 06/01/2005 | Disapproved -FEE REQUIRED | ARITTER |
| Note: DOWN CELLS NEXT TO WINDOWS ON BOTH SIDES OF ENTRY NOT FILLED. | |||
| ALL ROUGH | 06/01/2005 | Disapproved -FEE REQUIRED | ARITTER |
| Note: 1. NO PRESSURE ON SECOND ROUGH OF PLUMBING 2. NO STRAP ON TRUSS 23 AT NEAR WALL- REQ 2 META 20 3. NO STRAP ON TRUSS T24 ON OUTSIDE WALL- 2 META 20 4. NAIL STRAPS ON TRUSSES T25 AND T26 ON RIGHT SIDE OF ENTRY 5. BRACING MISSING ON TRUSS T21 6. DRAFT STOP TOPS OF ARCHES | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/20/2005 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/16/2005 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: 1. BLOCK 4' SIDE OF TRANSITION SHEATHING BELOW HIP GIRDER. 2. BLOCK SPANS GREATER THAN 24" AT STEP TRUSSES. 3. PROVIDE ENGINEERING TO ALLOW OSB BREAKS THAT ARE NOT SUPPORTED BY TRUSSES OR BLOCK 16" O.C. TRUSS TO TRUSS. | |||
| LINTEL | 04/18/2005 | APPROVED | MMOORE |
| MONOLITHIC SLAB INSPECTION/SLAB | 04/04/2005 | APPROVED | DROCKWELL |
| FIRST ROUGH PLUMBING INSPECTION | 04/01/2005 | APPROVED | JHINDMAN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/08/2005 | 03/11/2005 |
| Note: Released By: LWOODROME 3-11-05 Approved for release as noted on plan cover sheet. Checked by FR | |||
| DSD | COMPLETE | 03/04/2005 | 03/08/2005 |
| Note: Released By: JCALVERT | |||
| ENG | COMPLETE | 03/04/2005 | 03/10/2005 |
| Note: Released By: MLUNDGREN | |||
| LDS | COMPLETE | 03/04/2005 | 03/15/2005 |
| Note: Released By: CGOEWEY Held By: CGOEWEY Held By: CGOEWEY 3/14/05 (DD) EXISTING TREES? IF NOT, PLEASE INDICATE ON SITE PLAN FOUR PROPOSED TREES, TWO SHADE, TWO INDEX |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤200.00 | 09/30/2005 |
| EARLY POWER INSPECTION | ¤40.00 | 09/30/2005 |
| REINSPECTION FEE | ¤40.00 | 09/30/2005 |
| REINSPECTION FEE | ¤40.00 | 09/30/2005 |
| REINSPECTION FEE | ¤40.00 | 09/30/2005 |
| REINSPECTION FEE | ¤40.00 | 09/30/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 03/15/2005 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 03/15/2005 |
| ADMIN FEE | ¤20.00 | 03/15/2005 |
| BUILDING CODE ADMIN FUND | ¤13.46 | 03/15/2005 |
| ELECTRIC FEE | ¤126.00 | 03/15/2005 |
| ENGINEERING PERMIT FEES | ¤80.00 | 03/15/2005 |
| FIRE RES IMPACT FEE 4-1-04 | ¤168.91 | 03/15/2005 |
| MECHANICAL FEE | ¤126.00 | 03/15/2005 |
| PERMIT FEE | ¤624.00 | 03/15/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 03/15/2005 |
| PLAN CHECK FEE | ¤64.00 | 03/15/2005 |
| PLUMBING FEE | ¤126.00 | 03/15/2005 |
| RADON FEE | ¤13.46 | 03/15/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,367.74 |