I want to search for...
Permit #2005030511
Permit Details
Status: COED
| Parcel Id: 07-11-31-7035-00680-0310 |
| CONDITIONED SPACE: 2882 sqft |
| GARAGE: 568 sqft |
| SCREEN PORCH (SOLID ROOF) : 392 sqft |
| OPENED PORCH (WITH ROOF) : 112 sqft |
| Total Square Footage: 3954 sqft |
| Block: 0068 |
| Subdivision: - |
| Job Phone: (386)447-0836 |
| Location Address: 42 BUTTONWORTH DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/15/2005 |
| NOC: RECORDED |
| Applicant name: ANTONIO AMARAL JR |
| Owner: AZE & ASSOCIATES ENTERPRISES INC. |
|
Address P.O. BOX 352711 PALM COAST, FL 32135 |
| Lot: 310 |
| Contracted Stated Job Value: ¤155,900.00 |
| Job Description: SINGLE-FAMILY RESIDENCE |
| Type: CN |
Contractor
WORLD CLASS HOMES OF NE FLORIDA INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
13 UTILITY DR PALM COAST, FL 32137 |
RR282811317 (Exp: 08/31/2011) | (386)447-0836 | (386)447-7959 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 09/07/2005 | FINAL APPROVED | ARITTER |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 09/06/2005 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: 1. MISSING BACK FLOW PREVENTER ON FAUCET AT GARAGE. 2. SMOKE DETECTORS NOT SCHEDULED AT ELECTRIC PANEL. 3. HOT AND COLD WATER COPPER NOT BONDED AT W/H. 4. MISSING WATER HAMMER ARRESTER AT DISH WASHER. 5. SMOKE DETECTORS NOT WORKING. 6. TOILLET NOT SEALED AT BASE. | |||
| UTILITY COMPANY FINAL | 09/02/2005 | APPROVED - AS NOTED | RZALESKI |
| Note: Back charge due to damaged meter pit | |||
| ENGINEERING FINAL | 08/30/2005 | APPROVED | FTORO |
| Note: no box....1 driveway re-insp $35 | |||
| PRE DRIVEWAY | 08/05/2005 | APPROVED | FTORO |
| DRIVEWAY | 07/20/2005 | Disapproved - NO FEE | FTORO |
| Note: not formed | |||
| INSULATION INSPECTION | 06/27/2005 | APPROVED | MMOORE |
| ALL ROUGH | 06/23/2005 | APPROVED - AS NOTED | ARAYMOND |
| Note: ELECTRICAL INCOMPLETE | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 06/02/2005 | APPROVED - AS NOTED | MMOORE |
| Note: Grout under trusses, Check all ties and braces before All Rough inspection. | |||
| LINTEL | 05/10/2005 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 05/09/2005 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: 1. Must have minimum 3/4" concrete cover around down cells for corrosion protection FBC 1908.6 Table 2. Missing cells per typical stepped bond beam " D-1 3. Expose cell in garage at l-8 Beam 4. Provide engineering to allow the intersection of L9 beam and L6 window beam, submit to building department for approval prior to next inspection. | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 04/26/2005 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 04/25/2005 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 06/20/2005 | 06/20/2005 |
| Note: Released By: LWOODROME on: 6/20/2005 Revision: Exterior wall and truss modification | |||
| DSD | COMPLETE | 03/17/2005 | 03/28/2005 |
| Note: Released By: MWALLENBERG Held By: JCALVERT Need Sealed Survey | |||
| ENG1 | COMPLETE | 03/17/2005 | 03/23/2005 |
| Note: Released By: MLUNDGREN | |||
| URB | COMPLETE | 03/17/2005 | 04/04/2005 |
| Note: Released By: CGOEWEY | |||
| BLD | COMPLETE | 06/14/2005 | |
| Note: Released By: LWOODROME on: 6/14/2005 Revision: Girder truss support | |||
| BLD | COMPLETE | 04/13/2005 | |
| Note: Released By: LWOODROME 4-13-05 Approved for release as noted on plan cover sheet. Checked by CC and FR |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 09/13/2005 |
| REINSPECTION FEE | ¤40.00 | 09/13/2005 |
| REVISION | ¤40.00 | 09/13/2005 |
| REVISION | ¤40.00 | 09/13/2005 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 09/13/2005 |
| UTILITIES DAMAGE BACKCHARGE | ¤79.40 | 09/13/2005 |
| UTILITIES DAMAGE BACKCHARGE | 09/13/2005 | |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 04/15/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 04/15/2005 |
| ADMIN FEE | ¤20.00 | 04/15/2005 |
| BUILDING CODE ADMIN FUND | ¤19.77 | 04/15/2005 |
| ELECTRIC FEE | ¤165.60 | 04/15/2005 |
| ENGINEERING PERMIT FEES | ¤80.00 | 04/15/2005 |
| FIRE RES IMPACT FEE 4-1-04 | ¤168.91 | 04/15/2005 |
| MECHANICAL FEE | ¤165.60 | 04/15/2005 |
| PERMIT FEE | ¤881.40 | 04/15/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 04/15/2005 |
| PLAN CHECK FEE | ¤90.40 | 04/15/2005 |
| PLUMBING FEE | ¤165.60 | 04/15/2005 |
| RADON FEE | ¤19.77 | 04/15/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,657.36 |