| Parcel Id: 07-11-31-7037-00790-0070 |
| CONDITIONED SPACE: 1819 sqft |
| GARAGE: 470 sqft |
| SCREEN PORCH (SOLID ROOF) : 146 sqft |
| OPENED PORCH (WITH ROOF) : 67 sqft |
| Total Square Footage: 2502 sqft |
| Block: 0079 |
| Subdivision: - |
| Job Phone: (386) 672-8285 |
| Location Address: 145 LINDSAY DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/18/2005 |
| NOC: RECORDED |
| Applicant name: Vanacore Construction Inc. (Residential Contractor |
| Owner: DONAI CARL B |
| Lot: 070 |
| Contracted Stated Job Value: ¤135,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
| Type |
Request Date |
Result |
Inspector |
|
FINAL COMPLETE BUILDING INSPECTION |
11/02/2005 |
FINAL APPROVED |
JLEVRAULT |
|
ENGINEERING FINAL |
10/28/2005 |
APPROVED |
FTORO |
|
Note: 0 road damages
|
|
UTILITY COMPANY FINAL |
10/27/2005 |
APPROVED |
RZALESKI |
|
DRIVEWAY |
09/29/2005 |
APPROVED |
FTORO |
|
RESIDENTIAL EARLY POWER |
09/15/2005 |
APPROVED |
MMORATTO |
|
INSULATION INSPECTION |
08/03/2005 |
APPROVED |
MMOORE |
|
Note:
|
|
ALL ROUGH |
08/01/2005 |
APPROVED |
ARITTER |
|
Note: THIS IS A REINSPECTION
|
|
ALL ROUGH |
07/28/2005 |
Disapproved -FEE REQUIRED |
ARAYMOND |
|
Note: 1. NO STREET PRESSURE ON WATER LINES.
2. A/C PLENUM MUST HAVE DOUBLE SHEATHING TOP.
|
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
07/11/2005 |
APPROVED |
MMOORE |
|
Note: THIS IS A REINSPECTION....SEE NON-COMPLIANCE SHEET IN BOX
|
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
06/30/2005 |
Disapproved -FEE REQUIRED |
MMOORE |
|
Note: GARAGE ENTRY DOOR INTO HOUSE MISSING STRAP ON RIGHT -SIDE AT HEADER, 2 PLY TRUSS #TO4 OVER 2X4 SHEAR WALL NOT STRAPPED TO KNEE WALL BELOW AND THE KNEE WALL TO FRAMED WALL BELOW. MASTER BEDROOM/GABLE ENDS OVER WINDOW/ MISSING 2X6 BOLTED LEDGER WITH GABLE NAILED TO IT. BEDROOM #2 SAME AS LAST ITEM. 2 PLY TRUSS #T-18 OVER NOOK WINDOW/ WRAP-OVER STRAPS NOT NAILED, TRUSS # T11 NEEDS 2ND STRAP AT BEDROOM #2 END OF TRUSS
|
|
DOWN CELL |
06/30/2005 |
APPROVED |
MMOORE |
|
LINTEL |
06/14/2005 |
APPROVED |
MMOORE |
|
MONOLITHIC SLAB INSPECTION/SLAB |
06/02/2005 |
APPROVED |
MMOORE |
|
FIRST ROUGH PLUMBING INSPECTION |
06/01/2005 |
APPROVED |
ARITTER |