I want to search for...
Permit #2005040102
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-01410-0240 |
| CONDITIONED SPACE: 1520 sqft |
| GARAGE: 413 sqft |
| OPENED PORCH (WITH ROOF) : 21 sqft |
| PATIO/DECK (NO ROOF) : 180 sqft |
| Total Square Footage: 2134 sqft |
| Block: 0141 |
| Subdivision: - |
| Job Phone: (904) 646-1186 |
| Location Address: 67 LEIDEL DR |
| Type: RRI - RESIDENTIAL RE-ISSUE PERMIT |
| Issue Date: 05/02/2005 |
| NOC: RECORDED |
| Applicant name: Maronda Homes Inc. (Residential Contractor) |
| Owner: MARONDA HOMES |
|
Address 11200ST. JOHNS IND. PKWY N. #2 JACKSONVILLE, FL 32246 |
| Lot: 240 |
| Contracted Stated Job Value: ¤87,000.00 |
| Job Description: RE ISSUE SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MARONDA HOMES INC. (RES)
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 600458 Jacksonville, FL 32223 |
CRC057354 (Exp: 08/31/2006) | (904) 646-1186 | (904)646-9553 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 08/23/2005 | FINAL APPROVED | ARITTER |
| ENGINEERING FINAL | 08/10/2005 | APPROVED | FTORO |
| Note: 0 road damages | |||
| UTILITY COMPANY FINAL | 08/09/2005 | APPROVED | DASHBURN |
| DRIVEWAY | 07/25/2005 | APPROVED | FTORO |
| INSULATION INSPECTION | 06/30/2005 | APPROVED | MMOORE |
| ALL ROUGH | 06/22/2005 | APPROVED | TOUTLAND |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 06/16/2005 | APPROVED | MMOORE |
| Note: GROUT TRUSSES 1/2 TO 3/4 IN PLACES, SHEATHING OK, FILL ONE DOWN CELL AT FRONT OF BUILDING, DOWN CELLS OK, NO PLANS OR TRUSS ENGINEERING IN INSPECTION BOX, CHECK BRACES/TIES AT ALLROUGH INSP. | |||
| LINTEL | 05/24/2005 | APPROVED | MMOORE |
| LINTEL | 05/20/2005 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 8 BARS NEED TO ATTACH TO A DRILLED-IN DOWEL | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 05/10/2005 | APPROVED - AS NOTED | MMOORE |
| Note: Missing one dowel/see plans | |||
| FIRST ROUGH PLUMBING INSPECTION | 05/06/2005 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| FIRST ROUGH PLUMBING INSPECTION | 05/04/2005 | Disapproved -FEE REQUIRED | MMOORE |
| Note: No 5 ft. of head water |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/27/2005 | 04/30/2005 |
| Note: Released By: LWOODROME 4-30-05 Approved for release as noted on plan cover sheet. Checked by CC | |||
| DSD | COMPLETE | 04/04/2005 | 04/18/2005 |
| Note: Released By: JCALVERT Held By: JCALVERT Need Site Plab and Sealed survey | |||
| URB | COMPLETE | 04/04/2005 | 04/11/2005 |
| Note: Released By: CGOEWEY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 08/24/2005 |
| REINSPECTION FEE | ¤40.00 | 08/24/2005 |
| ADMIN FEE | ¤20.00 | 05/02/2005 |
| ELECTRIC FEE | ¤103.80 | 05/02/2005 |
| ENGINEERING PERMIT FEES | ¤80.00 | 05/02/2005 |
| MECHANICAL FEE | ¤103.80 | 05/02/2005 |
| PERMIT FEE | ¤479.70 | 05/02/2005 |
| PLAN CHECK FEE | ¤49.20 | 05/02/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤916.50 |