I want to search for...
Permit #2005040287
Permit Details
Status: COED
| Parcel Id: 07-11-31-7035-00250-0140 |
| CONDITIONED SPACE: 2597 sqft |
| GARAGE: 521 sqft |
| OPENED PORCH (WITH ROOF) : 281 sqft |
| Total Square Footage: 3399 sqft |
| Block: 0025 |
| Subdivision: - |
| Job Phone: (386)246-6328 |
| Location Address: 23 BURNSIDE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/05/2005 |
| NOC: RECORDED |
| Applicant name: EUGENE THOMAS |
| Owner: PEARSON, YVONNE M. |
|
Address 1025 S. BECH STREET APT 246 DAYTONA BEACH, FL 32114 |
| Lot: 140 |
| Contracted Stated Job Value: ¤255,144.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
CANTERBURY ESTATE HOMES INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
3222 NW 136TH ST GAINSVILLE, FL 32606 |
CBC1250201 (Exp: 09/30/2008) | (386)437-1270 | (386)437-9667 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 06/14/2006 | FINAL APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 06/08/2006 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: FLEX DUCT, USED FOR OFFSET, IN WATER HEATER FLUE. NO RATING WAS NOTED ON SAME. SUBMIT MATERIAL, WITH SPECIFICATIONS, TO PLAN REVIEW OR CHANGE TO APPROVED (A & O) FITTINGS. THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 06/07/2006 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: CORRIGATED PIPE WAS USED TO FABRICATE TWO 90 BENDS, FOR A HORIZONTAL OFFSET IN THE WATER HEATER FLUE. SUBMIT MATERIAL USED TO PLAN REVIEW. | |||
| STORMWATER FINAL INSPECTION | 05/23/2006 | APPROVED | BFCHAMBERLAIN |
| STORMWATER FINAL INSPECTION | 05/19/2006 | Disapproved -FEE REQUIRED | DSCHRAGER |
| Note: - Remove port o let regrade and sod same area as needed. - Remove concrete and debris from both property lines. - Remove large piece of concrete from property line (marked) regrade, seed and straw same area. | |||
| UTILITY COMPANY FINAL | 05/16/2006 | APPROVED | RANDRADE |
| DRIVEWAY | 04/20/2006 | APPROVED | BFCHAMBERLAIN |
| INSULATION INSPECTION | 03/17/2006 | APPROVED | JLEVRAULT |
| LATH /BRICK FLASHING | 03/15/2006 | APPROVED | JLEVRAULT |
| ALL ROUGH | 03/14/2006 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 02/17/2006 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: THIS IS A REINSPECTION... 1) Outside light boxes at garage are not bonded. 2) No pressure on water or waste lines. 3) No LP gas permit posted. Pressure was OK at time of inspection. 4) No attic access or lighted outlet. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/15/2006 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/13/2006 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: THIS IS A REINSPECTION VALLEY STRAP MISSING AT FRONT PORCH. TAPCON STRAP AT BATH TRUSS J041. NAIL FRONT BOXOUTS TO FRAMING AND NOT ONLY OSB. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/31/2006 | Disapproved -FEE REQUIRED | ARITTER |
| Note: THIS IS A REINSPECTION1. WORK NOTICES DATED (10-14-05) AND NOTICE DATED (11-23-05) NOT DONE 2. * ARCHITECTS TRUSS DRAWING NUMBERS DO NOT AGREE WITH TRUSS MANUF. NUMBERS. THIS CUNFUSES TRUSS CONNECTOR SCHEDULE. 3. PROBLEMS WITH TRUSS CONNECTORS-WINDOWS- SHEATHING ETC. ETC. | |||
| ALL ROUGH | 01/31/2006 | Disapproved -FEE REQUIRED | ARITTER |
| Note: NOT READY MUST COMPLETE INSPECTION #354 BEFORE ALL-ROUGH | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/23/2005 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: THIS IS A REINSPECTION Previous non-compliance list not complete. Check straps on front of house - nailed into plywood only. Too much else to list. Do thorough check before calling for reinspection. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/14/2005 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: 1. PROVIDE DOCUMENTATION TO ALLOW WALL SHEATHING TO BE NAILED 24" O.C. ON THE 4" SIDE OF PLYWOOD RATED 16" O.C. 2. MISS NAILED WALL SHEATHING. 3. GABLE END NOT X BRACED. 4. HJ04 NOT STRAPPED AND MISSING LOAD PATH. 5. MISSING STRAPS AT FRONT DORMER. 6. MISSING UPLIFT T33 NOT READY | |||
| LINTEL | 08/11/2005 | APPROVED | MMOORE |
| MONOLITHIC SLAB INSPECTION/SLAB | 07/13/2005 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 07/06/2005 | APPROVED | ARITTER |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 04/12/2006 | 04/19/2006 |
| Note: Released By: LAPTEKAR changed driveway to a straight driveway | |||
| BLD | COMPLETE | 02/06/2006 | 02/08/2006 |
| Note: Released By: LWOODROME Revision: Truss layout and connectors | |||
| DSD | COMPLETE | 04/10/2005 | 04/20/2005 |
| Note: Released By: DCHAUDOIN | |||
| ENG1 | COMPLETE | 04/10/2005 | 04/11/2005 |
| Note: Released By: MDOUSE | |||
| URB | COMPLETE | 04/10/2005 | 04/20/2005 |
| Note: Released By: CGOEWEY | |||
| BLD | COMPLETE | 04/21/2005 | |
| Note: Released By: CCOTE Held By: CCOTE Held By: CCOTE 4/21/05, fax sent. Awaiting legible plans. Awaiting structural items per fax. 6/2/05_Items received. 6/2/05_Approved for Release per plan cover sheet. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 06/15/2006 |
| REINSPECTION FEE | ¤40.00 | 06/15/2006 |
| REINSPECTION FEE | ¤40.00 | 06/15/2006 |
| REINSPECTION FEE | ¤40.00 | 06/15/2006 |
| REINSPECTION FEE | ¤40.00 | 06/15/2006 |
| REINSPECTION FEE | ¤40.00 | 06/15/2006 |
| REINSPECTION FEE | ¤40.00 | 06/15/2006 |
| REINSPECTION FEE | ¤40.00 | 06/15/2006 |
| REVISION | ¤40.00 | 06/15/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 06/15/2006 |
| SW REVISION | ¤40.00 | 06/15/2006 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 07/05/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 07/05/2005 |
| ADMIN FEE | ¤20.00 | 07/05/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 07/05/2005 |
| BUILDING CODE ADMIN FUND | ¤17.00 | 07/05/2005 |
| ELECTRIC FEE | ¤183.60 | 07/05/2005 |
| ENGINEERING PERMIT FEES | ¤80.00 | 07/05/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 07/05/2005 |
| MECHANICAL FEE | ¤183.60 | 07/05/2005 |
| PERMIT FEE | ¤998.40 | 07/05/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 07/05/2005 |
| PLAN CHECK FEE | ¤102.40 | 07/05/2005 |
| PLUMBING FEE | ¤183.60 | 07/05/2005 |
| RADON FEE | ¤17.00 | 07/05/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,124.98 |