I want to search for...

Permit #2005041092

Permit Details

Status: CANCEL

Parcel Id: 07-11-31-7037-01070-0330
CONDITIONED SPACE: 2525 sqft
GARAGE: 775 sqft
SCREEN PORCH (SOLID ROOF) : 184 sqft
OPENED PORCH (WITH ROOF) : 75 sqft
Total Square Footage: 3559 sqft
Block: 0107
Subdivision: -
Job Phone: (386)246-6328
Location Address: 2 LEWISDALE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/14/2005
NOC: Unknown
Applicant name: EUGENE THOMAS
Owner: CANTERBURY ESTATES INC
Lot: 330
Contracted Stated Job Value: ¤204,728.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

CANTERBURY ESTATE HOMES INC.
Status Location Address State License Number Phone Fax
CANCEL

3222 NW 136TH ST

GAINSVILLE, FL 32606

CBC1250201 (Exp: 09/30/2008) (386)437-1270 (386)437-9667

Sub Contractors

MICHAEL G MORELLO JR
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32137

CAC014293 (Exp: 08/31/2014) (386)447-3950 (386)446-4614
ALFERD MITCHUM FUTCH
Status Location Address State License Number Phone Fax
CANCEL

1218 San Jose Blvd

Holly Hill, FL 32117

CFC044175 (Exp: 08/31/2012) (386) 672-3576 (386)672-0107
STEPHEN M RENDE
Status Location Address State License Number Phone
CANCEL

22 ALAMANDA DRIVE

ORMOND, FL 32176

CCC058058 (Exp: 08/31/2020) 386-439-7156
RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 1963

Bunnell, FL 32110

ER0011613 (Exp: 08/31/2008) (386) 437-0607 (386)437-1847

Inspection History

Type Request Date Result Inspector
UTILITY COMPANY FINAL 06/06/2007 APPROVED TSCHWEERS
UTILITY COMPANY FINAL 05/31/2007 APPROVED TSCHWEERS
STORMWATER FINAL INSPECTION 02/09/2007 APPROVED DRANDALL
STORMWATER FINAL INSPECTION 02/01/2007 Disapproved -FEE REQUIRED DRANDALL
Note: place sod in property swale where exposed.....seed & straw exposed earth left adj. property.....left side of house won't drain to front of house [ see flags] water pooling at a/c unit.....remove dirt from street left adj. property.....remove concrete washout from right swale, & sod same area.....remove washout [dirt] from right rear of property and sod same area
DRIVEWAY 11/13/2006 APPROVED - AS NOTED GLALIMA
Note: DW inspection not required.\\wk
INSULATION INSPECTION 09/06/2006 APPROVED MMOORE
ALL ROUGH 06/29/2006 CANCELLED BY APPLICANT MMOORE
ALL ROUGH 06/13/2006 APPROVED MMOORE
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/28/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/24/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. PAGE "TYPICAL CMU DETAILS" AT DENOTE BY 'V' H2.5 MISSING 2. 2-PLY's AT BOLTED HANGERS / ALL LOSE 3. AT DINING ROOM WINDOW (ABOVE) AT SHORT KNEE WALL STUDS NOT ATTACHED TOP AND BOTTOM WITH CONNECTORS 4. KNEE WALL AT RIGHT ENTRY AY FRONT DOOR ONE BOLT NOT EMBEDDED 5. PAGE WITH 'FRAME WALL OPENING DETAIL' / BONUS ROOM WINDOW STRAPPING MISSISSING 6. CONNECTORS TOP OF NOOK WINDOW ATTACH TO TRUSSES ABOVE 7. STRAP FIREPLACE RAFTERS TO BLOCK WALL 8. 2-PLY M. BEDROOM TRUSS #13 NAIL TIGHT TOGETHER 9. UPLIFT OF SAME AT REAR WALL
FOOTER 04/03/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
FOOTER 03/31/2006 CANCELLED BY INSPECTOR MMOORE
Note: NEED MORE SLEEVING IN FOOTER
LINTEL 02/03/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
LINTEL 02/02/2006 Disapproved -FEE REQUIRED MMOORE
Note: THIS IS A REINSPECTION REFER TO FOUNDATION PLAN/ COLUMN FTG. DETAIL "EACH COLUMN" REQUIRES 2 #5 FROM FTG. TO TIE BEAM
LINTEL 01/30/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. PAGE "FOUNDATION PLAN" TYP 16" COLUMN FTG DETAIL (IN YELLOW) COLUMN HAS ONLY I BAR EACH (NOT TWO) AS PER PLAN / EPOXEE 2ND BAR 2. BACKWALL VERTICAL BAR (SEE PLANS) NO DOWEL
LINTEL 01/27/2006 Disapproved -FEE REQUIRED JLEVRAULT
Note: 1. several dowela missing- highlited on plans . steel in lintel not tied. down rod in left column at entrance not tied. front entrance on plan not to as built- submit revised plans to plans dept. for approval or build to plan.
MONOLITHIC SLAB INSPECTION/SLAB 12/16/2005 APPROVED JLEVRAULT
FIRST ROUGH PLUMBING INSPECTION 12/15/2005 APPROVED JLEVRAULT
TEMPORARY POLE 12/15/2005 APPROVED JLEVRAULT
FINAL COMPLETE BUILDING INSPECTION

Review History

Department Status Date In Date Out
BLD COMPLETE 03/23/2006 03/23/2006
Note: Released By: LWOODROME Revision: Footings @ bonus room
BLD HOLD 03/01/2006 03/02/2006
Note: Held By: LWOODROME PLAN REVIEW COMMENTS: " Provide 2 copies of revision drawings, which are signed and sealed, by the design professional of record, for this project. Larry Woodrome, CBO Chief Plans Examiner City of Palm Coast 386-986-3786
BLD COMPLETE 09/27/2005 10/10/2005
Note: Released By: LWOODROME Revision: Whole house plan
ZON COMPLETE 09/22/2005 09/27/2005
Note: Released By: HHERKERT
ZON HOLD 09/16/2005 09/22/2005
Note: Held By: HHERKERT need corrected tree survey, existing tree survey shows 1 tree on the lower right corner of the lot and will impede vision clearance for the corner intersection
ENG1 COMPLETE 08/31/2005 09/30/2005
Note: Released By: LAPTEKAR this is a private subdivision.....corner lot ....the driveway is okay
BLD COMPLETE 05/09/2005 05/10/2005
Note: Released By: IVAZQUEZ Held By: CCOTE Placed on Hold by Carl Cote, 5/10/05, fax sent. Awaiting submission of structural items per fax.
ENG1 HOLD 04/29/2005 08/31/2005
Note: Held By: LAPTEKAR corner lot...need site plan to scale...driveway flair needs to be 60' from intersection
ZON HOLD 04/29/2005 05/09/2005
Note: Held By: HHERKERT on: 6/20/2005 the site plan does not match the floor plan. need new site plan, does not meet front/side setback of 25'
BLD COMPLETE 06/20/2005
Note: Released By: CCOTE on: 6/20/2005 Approved for Release per plan cover sheet.
BLD COMPLETE 06/08/2005
Note: Released By: IVAZQUEZ Held By: CCOTE on: 6/20/2005 Held By: CCOTE on: 6/20/2005 Awaiting response to remaing structural items from previous fax_New Fax sent.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN FEE ¤20.00 12/14/2005
ARC HOUSE REVIEW ¤125.00 12/14/2005
BUILDING CODE ADMIN FUND ¤17.80 12/14/2005
ELECTRIC FEE ¤153.60 12/14/2005
FIRE RES IMPACT FEE 4-1-05 ¤173.47 12/14/2005
MECHANICAL FEE ¤153.60 12/14/2005
PERMIT FEE ¤803.40 12/14/2005
PARKS IMPACT FEE 11-2-04 ¤1,120.91 12/14/2005
PLAN CHECK FEE ¤82.40 12/14/2005
PLUMBING FEE ¤153.60 12/14/2005
RADON FEE ¤17.80 12/14/2005
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 12/14/2005
STORM WATER PERMIT FEES ¤80.00 12/14/2005
REVISION ¤40.00 12/14/2005
TRANSPORTATION IMPACT FEE3/RES ¤2,885.00 12/14/2005
REVISION ¤40.00
STORMWATER REINSPECTION FEE ¤35.00
STORMWATER REINSPECTION FEE ¤35.00
REINSPECTION FEE ¤40.00
REINSPECTION FEE ¤40.00
REINSPECTION FEE ¤40.00
REINSPECTION FEE ¤40.00
Fees Total Due: ¤270.00 Total Paid: ¤9,426.58