| Parcel Id: 07-11-31-7037-01120-0020 |
| CONDITIONED SPACE: 2848 sqft |
| GARAGE: 539 sqft |
| OPENED PORCH (WITH ROOF) : 216 sqft |
| OPENED PORCH (WITH ROOF) : 107 sqft |
| OPENED PORCH (WITH ROOF) : 67 sqft |
| Total Square Footage: 3777 sqft |
| Block: 0112 |
| Subdivision: - |
| Job Phone: (386)447-5225 |
| Location Address: 17 LEWIS DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/21/2005 |
| NOC: RECORDED |
| Applicant name: MOJI BABAZADEH |
| Owner: INTERVEST CONSTRUCTION INC |
| Lot: 020 |
| Job Description: RESIDENTIAL SINGLE FAMILY HOME |
| Type: CN |
| Type |
Request Date |
Result |
Inspector |
|
FINAL COMPLETE BUILDING INSPECTION |
03/07/2006 |
FINAL APPROVED |
JLEVRAULT |
|
ENGINEERING FINAL |
02/08/2006 |
APPROVED |
BFCHAMBERLAIN |
|
Note: 61 s.f. road damage.....bonded builder
|
|
UTILITY COMPANY FINAL |
02/08/2006 |
APPROVED |
RANDRADE |
|
RESIDENTIAL EARLY POWER |
02/03/2006 |
APPROVED |
MMOORE |
|
PRE DRIVEWAY |
12/29/2005 |
APPROVED |
FTORO |
|
Note: THIS IS A REINSPECTION
|
|
PRE DRIVEWAY |
12/28/2005 |
Disapproved -FEE REQUIRED |
FTORO |
|
Note: not formed
|
|
PRE DRIVEWAY |
12/27/2005 |
CANCELLED BY APPLICANT |
LAPTEKAR |
|
INSULATION INSPECTION |
11/16/2005 |
APPROVED |
MMOORE |
|
ALL ROUGH |
11/14/2005 |
APPROVED |
JLEVRAULT |
|
Note: THIS IS A REINSPECTION
|
|
ALL ROUGH |
11/10/2005 |
Disapproved -FEE REQUIRED |
JLEVRAULT |
|
Note: THIS IS A REINSPECTION Top stairs still not correct.
|
|
ALL ROUGH |
11/02/2005 |
Disapproved -FEE REQUIRED |
JLEVRAULT |
|
Note: THIS IS A REINSPECTION Top short stairs do not meet code. Two middle steps have an 8 1/2" rise. Maximum is 7 3/4".
|
|
ALL ROUGH |
10/27/2005 |
Disapproved -FEE REQUIRED |
JLEVRAULT |
|
Note: Correct all stairs. Not to plans or code.
|
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
10/13/2005 |
APPROVED |
ARAYMOND |
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
10/12/2005 |
Disapproved -FEE REQUIRED |
ARITTER |
|
Note: THIS IS A REINSPECTION
STRAP PORCH CORNER ROOF AT RIGHT REAR- TOP- THIRD NOTICE
1ST NOTICE - 10-07-05
2ND- 10-11-05
3RD- 10-12-05
|
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
10/11/2005 |
Disapproved -FEE REQUIRED |
MMOORE |
|
Note: porch corner needs to be strapped to blocking as requested at last non-compliance
|
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
10/07/2005 |
Disapproved -FEE REQUIRED |
MMOORE |
|
Note: 1. jack #'s J201 & J200 need to be strapped to shear wall 2. exterior coil strapping at rear wall at exterior of building only nailed through osb in places and not through blocking if required 3. fireplace rafters need straps 4. porch block corner at upper framing needs strapping or visible means of anchorage for inspection
|
|
LINTEL |
09/14/2005 |
APPROVED |
MMOORE |
|
MONOLITHIC SLAB INSPECTION/SLAB |
08/26/2005 |
APPROVED |
MMOORE |
|
FIRST ROUGH PLUMBING INSPECTION |
08/24/2005 |
APPROVED |
ARAYMOND |