I want to search for...

Permit #2005060364

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-01650-0030
CONDITIONED SPACE: 1725 sqft
GARAGE: 420 sqft
OPENED PORCH (WITH ROOF) : 282 sqft
OPENED PORCH (WITH ROOF) : 42 sqft
Total Square Footage: 2469 sqft
Block: 0165
Subdivision: -
Job Phone: (386)447-0836
Location Address: 236 LONDON DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/05/2005
NOC: RECORDED
Applicant name: ANTONIO AMARAL JR
Owner: FIGUERO FRANCISCO P &

Address

PATRICIA M H&W

WELLINGTON, FL 33414

Lot: 030
Contracted Stated Job Value: ¤123,900.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

WORLD CLASS HOMES OF NE FLORIDA INC
Status Location Address State License Number Phone Fax
CANCEL

13 UTILITY DR

PALM COAST, FL 32137

RR282811317 (Exp: 08/31/2011) (386)447-0836 (386)447-7959

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 03/02/2006 FINAL APPROVED MMOORE
ENGINEERING FINAL 02/28/2006 APPROVED BFCHAMBERLAIN
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 02/28/2006 CANCELLED BY INSPECTOR LAPTEKAR
Note: already sceduled for eng insp
UTILITY COMPANY FINAL 02/10/2006 APPROVED RANDRADE
ENGINEERING FINAL 02/09/2006 Disapproved -FEE REQUIRED BFCHAMBERLAIN
Note: seed and straw left and right sides
PRE DRIVEWAY 01/10/2006 APPROVED BFCHAMBERLAIN
INSULATION INSPECTION 11/17/2005 APPROVED MMOORE
ALL ROUGH 11/14/2005 APPROVED - AS NOTED JLEVRAULT
Note: THIS IS A REINSPECTION Replace cut wire sheath in kitchen underfloor wiring.
ALL ROUGH 11/10/2005 Disapproved -FEE REQUIRED JLEVRAULT
Note: No pressure on water lines. Prepare concrete floor for underfloor wires in kitchen.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/28/2005 APPROVED - AS NOTED MMOORE
Note: THIS IS A REINSPECTION ***************MISSED AT LAST INSPECTION: TRUSS # 14 AROUND LEFT OF MAIN ENTRY DOOR/ FIRST TRUSS/ STRAP BENT OVER TOO FAR/ EITHER PACK-OUT OR TAPCON ANOTHER STRAP .....HAVE READY FOR BY ALL-ROUGH INSP. #262 AND # 354 PASSES
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/19/2005 Disapproved -FEE REQUIRED MMOORE
Note: THIS IS A REINSPECTION grout trusses
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/14/2005 Disapproved -FEE REQUIRED MMOORE
Note: T-121 2-ply at shear/garage needs ahchorage at this point
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/13/2005 Disapproved -FEE REQUIRED ARAYMOND
Note: 1. NO APPROVED PLANS OR TRUSS ENGINEERING ON SITE. 2. MISSED FILLED CELL
LINTEL 09/02/2005 APPROVED MMOORE
MONOLITHIC SLAB INSPECTION/SLAB 08/18/2005 APPROVED MMOORE
FIRST ROUGH PLUMBING INSPECTION 08/16/2005 APPROVED ARAYMOND

Review History

Department Status Date In Date Out
BLD COMPLETE 06/22/2005 06/29/2005
Note: Released By: CCOTE Approved for Release per plan cover sheet.
ENG1 COMPLETE 06/13/2005 06/22/2005
Note: Released By: HHERKERT on: 6/22/2005
ZON COMPLETE 06/13/2005 06/30/2005
Note: Released By: LMUSGROVE

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 03/06/2006
REINSPECTION FEE ¤40.00 03/06/2006
REINSPECTION FEE ¤40.00 03/06/2006
REINSPECTION FEE ¤40.00 03/06/2006
STORMWATER REINSPECTION FEE ¤35.00 03/06/2006
UTILITIES DAMAGE BACKCHARGE ¤45.00 03/06/2006
TRANSPORTATION IMPACT FEE3/RES ¤2,885.00 07/05/2005
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 07/05/2005
ADMIN FEE ¤20.00 07/05/2005
ARC HOUSE REVIEW ¤125.00 07/05/2005
BUILDING CODE ADMIN FUND ¤12.35 07/05/2005
ELECTRIC FEE ¤113.40 07/05/2005
ENGINEERING PERMIT FEES ¤80.00 07/05/2005
FIRE RES IMPACT FEE 4-1-05 ¤173.47 07/05/2005
MECHANICAL FEE ¤113.40 07/05/2005
PERMIT FEE ¤542.10 07/05/2005
PARKS IMPACT FEE 11-2-04 ¤1,120.91 07/05/2005
PLAN CHECK FEE ¤55.60 07/05/2005
PLUMBING FEE ¤113.40 07/05/2005
RADON FEE ¤12.35 07/05/2005
Fees Total Due: ¤0.00 Total Paid: ¤9,206.98