| Parcel Id: 07-11-31-7009-00200-0350 |
| CONDITIONED SPACE: 1819 sqft |
| GARAGE: 470 sqft |
| OPENED PORCH (WITH ROOF) : 146 sqft |
| OPENED PORCH (WITH ROOF) : 67 sqft |
| Total Square Footage: 2502 sqft |
| Block: 0020 |
| Subdivision: - |
| Job Phone: (386) 672-8285 |
| Location Address: 21 FAIRMONT LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/12/2005 |
| NOC: RECORDED |
| Applicant name: Vanacore Construction Inc. (Residential Contractor |
| Owner: EDWIN & NANCY MONCAVO |
| Lot: 350 |
| Contracted Stated Job Value: ¤150,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type |
Request Date |
Result |
Inspector |
|
FINAL COMPLETE BUILDING INSPECTION |
01/30/2006 |
FINAL APPROVED |
TOUTLAND |
|
ENGINEERING FINAL |
01/19/2006 |
APPROVED - AS NOTED |
BFCHAMBERLAIN |
|
Note: remove sod and fill from left side fence.\\bc
Builder brought in a signed letter from the adjacent homeowner stating that fill against the fence os okay.
Gave them final approval after discussing it with inspector Brian C.\\wk
|
|
UTILITY COMPANY FINAL |
01/19/2006 |
APPROVED |
RANDRADE |
|
RESIDENTIAL EARLY POWER |
12/29/2005 |
APPROVED |
JMCGOWEN |
|
PRE DRIVEWAY |
12/27/2005 |
APPROVED |
FTORO |
|
INSULATION INSPECTION |
10/24/2005 |
APPROVED |
ARAYMOND |
|
ALL ROUGH |
10/13/2005 |
APPROVED |
JMCGOWEN |
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
10/12/2005 |
APPROVED |
ARAYMOND |
|
Note: THIS IS A REINSPECTION
|
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
09/28/2005 |
Disapproved -FEE REQUIRED |
ARAYMOND |
|
Note: THIS IS A REINSPECTION
1. PREVIOUS ITEM #2 INCOMPLETE.
2. PREVIOUS ITEM #4 SIMPSON ALLOWS THE USE OF TWO STRAPS ONLY.
3. PREVIOUS ITEM #5 PROVIDE DOCUMENTATION THAT BUCKETS EITHER AND MEET THE UPLIFT REQUIREMENTS.
|
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
09/26/2005 |
Disapproved -FEE REQUIRED |
TOUTLAND |
|
Note: THIS IS A REINSPECTION
SEE PREVIOUS LIST
|
|
DOWN CELL |
09/22/2005 |
CANCELLED BY INSPECTOR |
JMCGOWEN |
|
Note: this inspection is done and included with the roof sheithing inspection
|
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
09/14/2005 |
Disapproved -FEE REQUIRED |
ARAYMOND |
|
Note: 1. MISSED NAILING
2. MISSED DOWN CELLS REAR
3. MISSED STRAPS AT CORNERS OF GARAGE
4. STRAPS FOT T-11 AT (K) DOES NOT MEET UPLIFT AND DOES NOT FOLLOW LOAD PATH.
5. PROVIDE ENGINEERING FOR POST AND HEADER AT LANAI FOR LOAD PATH.
NOT READY
|
|
LINTEL |
08/24/2005 |
APPROVED |
TOUTLAND |
|
Note: THIS IS A REINSPECTION
|
|
LINTEL |
08/23/2005 |
Disapproved -FEE REQUIRED |
ARAYMOND |
|
Note: MISSING CELLS ON FLOOR PLAN PER BOND BEAM TRANSITION DETAIL.
|
|
MONOLITHIC SLAB INSPECTION/SLAB |
08/11/2005 |
APPROVED |
TOUTLAND |
|
FIRST ROUGH PLUMBING INSPECTION |
08/10/2005 |
APPROVED |
ARAYMOND |