I want to search for...

Permit #2005061051

Permit Details

Status: COED

Parcel Id: 07-11-31-7013-00150-0090
CONDITIONED SPACE: 3100 sqft
GARAGE: 668 sqft
OPENED PORCH (WITH ROOF) : 140 sqft
Total Square Footage: 3908 sqft
Block: 0015
Subdivision: -
Job Phone: (386)445-7343
Location Address: 29 BRITTANY LN
Type: DU - DUPLEX
Issue Date: 08/31/2005
NOC: RECORDED
Applicant name: BURTON R BERMAN
Owner: OLIVEIRA, JOHN B.

Address

346 MINUTE ARMS ROAD

UNION, NJ 07083

Lot: 090
Contracted Stated Job Value: ¤190,000.00
Job Description: DUPLEX RESIDEDNCE
Type: CN

Contractor

PALM COAST HOMES & DEVELOPMENT CORP.
Status Location Address State License Number Phone
CANCEL

138 PALM COAST PARKWAY NE # 348

PALM COAST, FL 32137

CRC1326612 (Exp: 08/31/2012) (386)445-7343

Sub Contractors

JOHN FREDERICK WANERKA
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 350214

BUNNELL, FL 32135

EC0000585 (Exp: 08/31/2022) 386-446-9626 386-445-3131
MICHAEL DAVID CLARK
Status Location Address State License Number Phone
CANCEL

P. O. Box 918

Bunnell, FL 32110

CAC044867 (Exp: 09/30/2008) (386) 437-2001
MARTIN JOHN EVANS
Status Location Address State License Number
ACTIVE

14 FORT CAROLINE CT

BUNNELL, FL 32110

CFC057676 (Exp: 08/31/2026)

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 05/18/2007 FINAL APPROVED MMOORE
Note: THIS IS A REINSPECTION 1. NO PLACARD TO SIGN AT FINAL INSPECTION Contractor came in to schedule
FINAL COMPLETE BUILDING INSPECTION 05/09/2007 Disapproved -FEE REQUIRED MMOORE
Note: REQUESTED BY 1. HAMMER ARRESTOR VALVES REQUIRED UNDER KITCHEN SINKS 2. RESIDENTIAL EARLY POWER DATED 3-28-07 / SEE NOTES ABOUT ROMEX AT GARBAGE DISPOSALS 3. HOUSE NUMBERS M ISSING 4. MAX. OVERCURRENT PROTECTION FOR HEATER IS 50 AMPS. 5. KITCHEN REC. TO BE 24" FROM SINK ALONG BACKSPLASH TO IST PLUG IN REC. 6. ATTACH LFN CABLE TO WALL AT CONDENSOR 12" BELOW DISCONNECT 7. ABOVE #1 THRU #6 IS FOR BOTH UNITS 8. LEFT UNIT / RIGHT CLOSETS LIGHTS TO BE 12" FROM EDGE OF SHELF
STORMWATER FINAL INSPECTION 05/03/2007 APPROVED - AS NOTED DRANDALL
Note: THIS IS A REINSPECTION 48 sf road seed & straw was done by builder
UTILITY COMPANY FINAL 04/27/2007 APPROVED TSCHWEERS
STORMWATER FINAL INSPECTION 04/27/2007 Disapproved -FEE REQUIRED DRANDALL
Note: seed & straw all exposed earth on the rear adj. property.....remove all trash from rear adj. property.....left side of house appears to flow onto left side property, from a/c pad back, regrade to keep runoff on property and flow to front swale.....48 sf road damage
RESIDENTIAL EARLY POWER 03/28/2007 APPROVED LHITES
Note: squedule by Bert Berman CANNOT HAVE EXPOSED ROMEX TO DISPOSAL CHECK OUTLET SPACING IN KITCHEN COUNTER TOP EACH SIDE OF SINK
INSULATION INSPECTION 03/26/2007 APPROVED - AS NOTED LWOODROME
Note: Approved per engineer inspection letter.
PRE DRIVEWAY 10/16/2006 APPROVED DRANDALL
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/07/2006 APPROVED - AS NOTED LWOODROME
Note: Approved per Missed Inspection Engineering Letter.
FIREWALL FRAMING (DUPLEX) 05/15/2006 APPROVED JLEVRAULT
ALL ROUGH 05/10/2006 CANCELLED BY INSPECTOR JLEVRAULT
Note: THIS IS A REINSPECTION NEED TO PASS ROOF SHEATHING AND FIREWALL FRAMING FIRST. i SPOKE TO mIKE mOORE TODAY AND HE SAID HE GAVE THE BUILDER PERMISSION TO SHINGLE THE ROOF, MIKE ALSO SAID THAT HE LOOKED AT THE FIREWALL FRAMING BEFORE IT WAS DRYWALLED AND IT WAS FINE.MIKE SAID THERE WAS NOWHERE TO SIGN OFF FOR THE FIREWALL FRAMING ON THE PLACARD.
ALL ROUGH 05/02/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. ELECTRICAL CODE 314.17 (C) , 8" AT ELECTRICAL PANEL AT BUILDINGS #1 & #2 2. NO PRESSURE AT 2ND ROUGH PLUMBING AT BLDG. #1 & #2 3. 1 BOLT LEFT BUILDING AT GARAGE SHEAR NOT EMBEDDED 4. SHEATHING INSPECTION DID NOT PASS. WHY DID YOU CALL IN THE ALL-ROUGH? 5. ALL-ROUGH FAILS
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/18/2006 Disapproved -FEE REQUIRED MMOORE
Note: THIS IS A REINSPECTION....... PLANS FOR BOLTING OF GARAGE AND KITCHEN SHEAR WALLS
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/12/2006 Disapproved -FEE REQUIRED ARITTER
Note: THIS IS A REINSPECTION. NO TRUSS PLANS IN BOX.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/27/2006 CANCELLED BY APPLICANT ARITTER
LINTEL 02/13/2006 APPROVED JLEVRAULT
Note: THIS IS A REINSPECTION
LINTEL 02/01/2006 Disapproved -FEE REQUIRED ARITTER
Note: 1. MISSING CELL MARKED ON PLAN
MONOLITHIC SLAB INSPECTION/SLAB 01/03/2006 APPROVED MMOORE
FIRST ROUGH PLUMBING INSPECTION 12/27/2005 APPROVED ARITTER
Note: THIS IS A REINSPECTION
FIRST ROUGH PLUMBING INSPECTION 12/19/2005 Disapproved -FEE REQUIRED JLEVRAULT
Note: Not ready.

Review History

Department Status Date In Date Out
ZON COMPLETE 09/06/2006 09/08/2006
Note: Released By: ECOYNE
BLD COMPLETE 08/07/2006 08/07/2006
Note: Released By: CCOTE Approved for Release. Missed Inspection Engineer Letter (Roof Sheathing braces, ties, downcell)
BLD COMPLETE 04/06/2006 04/11/2006
Note: Released By: CCOTE Approved for Release. Revision: Restamp copy of plan set.
BLD HOLD 04/03/2006 04/04/2006
Note: Held By: LWOODROME PLAN REVIEW COMMENTS: " Provide the following details, which were include, on the original approved plan but omitted from the plan set provided as a replacement of the lost original plan: " Gable end framing detail. " Gable end bracing detail. " Exhaust fan and duct installation detail. " Clothes dryer exhaust-vent detail. Larry Woodrome, CBO Chief Plans Examiner City of Palm Coast 386-986-3786
BLD COMPLETE 07/19/2005 07/19/2005
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD COMPLETE 07/08/2005 07/13/2005
Note: Released By: IVAZQUEZ Held By: CCOTE Awaiting structural items per fax sent.
SWMD COMPLETE 07/07/2005
Note: Released By: KJOHNSON
ZON COMPLETE 07/06/2005
Note: Released By: IVAZQUEZ Held By: HHERKERT NEED CORRECT SQ FT TABULATION HOLD FOR ARC MEETING JULY 8TH
ZON COMPLETE 07/08/2005
Note: Released By: HHERKERT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤484.00 05/21/2007
EARLY POWER INSPECTION ¤40.00 05/21/2007
REINSPECTION FEE ¤40.00 05/21/2007
REINSPECTION FEE ¤40.00 05/21/2007
REINSPECTION FEE ¤40.00 05/21/2007
REINSPECTION FEE ¤40.00 05/21/2007
REINSPECTION FEE ¤40.00 05/21/2007
REINSPECTION FEE ¤40.00 05/21/2007
REVISION ¤40.00 05/21/2007
REVISION ¤0.00 05/21/2007
MISCELLANEOUS ¤40.00 05/21/2007
MISCELLANEOUS ¤40.00 05/21/2007
STORMWATER REINSPECTION FEE ¤35.00 05/21/2007
TRANSPORTATION IMPACT FEE3/RES ¤5,770.00 08/31/2005
PERMIT FEE ¤932.10 08/31/2005
PARKS IMPACT FEE 11-2-04 ¤2,241.82 08/31/2005
PLAN CHECK FEE ¤95.60 08/31/2005
PLUMBING FEE ¤173.40 08/31/2005
RADON FEE ¤19.54 08/31/2005
SCHOOL BOARD IMPACT FEE RES ¤7,200.00 08/31/2005
FIRE RES IMPACT FEE 4-1-05 ¤346.94 08/31/2005
MECHANICAL FEE ¤173.40 08/31/2005
ADMIN FEE ¤20.00 08/31/2005
ARC HOUSE REVIEW ¤125.00 08/31/2005
BUILDING CODE ADMIN FUND ¤19.54 08/31/2005
ELECTRIC FEE ¤173.40 08/31/2005
ENGINEERING PERMIT FEES ¤80.00 08/31/2005
Fees Total Due: ¤0.00 Total Paid: ¤18,289.74