I want to search for...
Permit #2005070401
Permit Details
Status: COED
| Parcel Id: 07-11-31-7023-00580-0110 |
| CONDITIONED SPACE: 2332 sqft |
| GARAGE: 438 sqft |
| OPENED PORCH (WITH ROOF) : 90 sqft |
| PATIO/DECK (NO ROOF) : 18 sqft |
| Total Square Footage: 2878 sqft |
| Block: 0058 |
| Subdivision: - |
| Job Phone: (904)596-6703 |
| Location Address: 46 WHEELING LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/28/2005 |
| NOC: RECORDED |
| Applicant name: K.B Homes of Jacksonville Inc. (Building Contracto |
| Owner: KB HOMES ORLANDO |
|
Address 735 FENTRESS DAYTONA BEACH, FL 32114 |
| Lot: 110 |
| Contracted Stated Job Value: ¤169,990.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
KB HOME ORLANDO, LLC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
9102 SOUTHPARK CENTER LOOP # 200 ORLANDO, FL 32819 |
CBC051212 (Exp: 08/31/2010) | (407)587-3531 | (407)587-2333 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 02/06/2006 | FINAL APPROVED | PGALLMANN |
| STORMWATER FINAL INSPECTION | 01/25/2006 | APPROVED | BFCHAMBERLAIN |
| Note: 21 sf road damage, $268. | |||
| UTILITY COMPANY FINAL | 01/18/2006 | APPROVED | RANDRADE |
| RESIDENTIAL EARLY POWER | 01/11/2006 | APPROVED | ARITTER |
| DRIVEWAY | 01/09/2006 | APPROVED | BFCHAMBERLAIN |
| INSULATION INSPECTION | 12/02/2005 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 11/30/2005 | Disapproved -FEE REQUIRED | MMOORE |
| Note: THIS IS A REINSPECTION...1. DRAFTSTOP MISSING UNDER TUB 2. DRAFTSTOP MISSING AT END OF CENTER WALL 3. BAFFLES ON 2ND FLOOR MISSING 4. DRAFTSTOP AROUND JOIST PENETRATIONS 5. 500 SQ. FT. AT JOIST / DRAFTSTOPS | |||
| INSULATION INSPECTION | 11/23/2005 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. DRAFTSTOP TOP OF ELECTRIC PANEL 2. STRAP HEADER AT GARAGE ENTRY DOOR PER PLAN 3. 500 SQ. FT. DRAFTSTOP AT FLOOR JOIST/ FIRESTOP 4. BAFFLES PUSHED INTO SOFFITS AGAINST BACK OF FASCIA 5. MISSING BAFFLES 6. BAFFLES TO BE CENTERED BETWEEN TRUSSES AND NO HOLES AT THE BOTTOMS FOR AIR FILTRATION | |||
| ALL ROUGH | 11/17/2005 | APPROVED | ARAYMOND |
| Note: THIS IS A REINSPECTION STRAP LUL TO STAIRWAY WALL | |||
| ALL ROUGH | 11/14/2005 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: Wirenuts and pigtails missing on some electrical boxes.Install proper screws in windows. Nail 2-ply lvl. Finish interior strapping. Reinforce second floor kneewall at stairs. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/02/2005 | APPROVED | ARITTER |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/01/2005 | Disapproved -FEE REQUIRED | ARITTER |
| Note: THIS IS A REINSPECTION 1. ITEM 2 ONNOTICE DATED 10-21-05 NOT DONE "BEAMS MUST BE BOLTED TOGETHER" | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/27/2005 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: THIS IS A REINSPECTION NO APPROVED PLANS ON SITE. NO INSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/21/2005 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. PHD/ GARAGE/ RIGHT SIDE MISSING SCREWS BOTH ENDS, NUTS ARE LOOSE 2. SEE PAGE S-1, DETAIL 2/S1 AND DETAIL "A"FOR LS BOLT PATTERN 3. TAPCON EYEBROWS AND ENDS OF EXTERNAL ARCHES | |||
| LINTEL | 10/03/2005 | APPROVED | MMOORE |
| MONOLITHIC SLAB INSPECTION/SLAB | 09/26/2005 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 09/22/2005 | Disapproved -FEE REQUIRED | MMOORE |
| Note: PLUMBERS REPLUMBING ONE AREA/TO BE RESPRAYED/ CALL-IN FOR RE-INSPECT | |||
| FIRST ROUGH PLUMBING INSPECTION | 09/20/2005 | APPROVED | ARAYMOND |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 07/25/2005 | 07/26/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R. | |||
| SWMD | COMPLETE | 07/14/2005 | 07/27/2005 |
| Note: Released By: WKINELL | |||
| ZON | COMPLETE | 07/14/2005 | 07/25/2005 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤268.00 | 02/13/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 02/13/2006 |
| REINSPECTION FEE | ¤40.00 | 02/13/2006 |
| REINSPECTION FEE | ¤40.00 | 02/13/2006 |
| REINSPECTION FEE | ¤40.00 | 02/13/2006 |
| REINSPECTION FEE | ¤40.00 | 02/13/2006 |
| REINSPECTION FEE | ¤40.00 | 02/13/2006 |
| REINSPECTION FEE | ¤40.00 | 02/13/2006 |
| REINSPECTION FEE | ¤40.00 | 02/13/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 07/28/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 07/28/2005 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 07/28/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 07/28/2005 |
| MECHANICAL FEE | ¤136.20 | 07/28/2005 |
| PERMIT FEE | ¤690.30 | 07/28/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 07/28/2005 |
| PLAN CHECK FEE | ¤70.80 | 07/28/2005 |
| PLUMBING FEE | ¤136.20 | 07/28/2005 |
| RADON FEE | ¤14.39 | 07/28/2005 |
| ADMIN FEE | ¤20.00 | 07/28/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 07/28/2005 |
| BUILDING CODE ADMIN FUND | ¤14.39 | 07/28/2005 |
| ELECTRIC FEE | ¤136.20 | 07/28/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,790.86 |