I want to search for...
Permit #2005070726
Permit Details
Status: COED
| Parcel Id: 07-11-31-7007-00470-0210 |
| CONDITIONED SPACE: 1815 sqft |
| GARAGE: 396 sqft |
| OPENED PORCH (WITH ROOF) : 172 sqft |
| OPENED PORCH (WITH ROOF) : 63 sqft |
| Total Square Footage: 2446 sqft |
| Block: 0047 |
| Subdivision: - |
| Job Phone: (386) 672-8285 |
| Location Address: 81 FREEMONT TURN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/21/2005 |
| NOC: RECORDED |
| Applicant name: JOSEPH TODD VANACORE |
| Owner: VAN DYKE ENTERPRISES, INC |
|
Address 125 TIDES EDGE PLACE PONTE VERDE BEACH, FL 32082 |
| Lot: 210 |
| Contracted Stated Job Value: ¤160,000.00 |
| Job Description: RESIDENTIAL SINGLE FAMILY HOME |
| Type: CN |
Contractor
VANACORE CONSTRUCTION INC.
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
1451 N US HIGHWAY 1 Ormond Beach, FL 32174 |
SUITE 13 Ormond Beach, FL 32174 |
CBC058991 (Exp: 08/31/2024) | (386) 672-8285 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 05/23/2006 | FINAL APPROVED | JMCGOWEN |
| STORMWATER FINAL INSPECTION | 05/19/2006 | APPROVED - AS NOTED | DSCHRAGER |
| Note: - 73 sqft of road damage. | |||
| STORMWATER FINAL INSPECTION | 05/18/2006 | Disapproved -FEE REQUIRED | DSCHRAGER |
| Note: - 73 sqft of road damage. - Seed and straw left and left rear property line. - Remove concrete and other debris from left property line. | |||
| UTILITY COMPANY FINAL | 04/21/2006 | APPROVED | RANDRADE |
| RESIDENTIAL EARLY POWER | 03/30/2006 | APPROVED | ARAYMOND |
| PRE DRIVEWAY | 03/28/2006 | APPROVED | BFCHAMBERLAIN |
| INSULATION INSPECTION | 02/03/2006 | APPROVED | ARAYMOND |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 02/02/2006 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: THIS IS A REINSPECTION same as previous | |||
| INSULATION INSPECTION | 02/01/2006 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: fpc 305.8 protecting shield plates min 1/16" shall extend 2" above sole plates and below top plates | |||
| ALL ROUGH | 01/26/2006 | APPROVED | MMOORE |
| LATH /BRICK FLASHING | 01/23/2006 | APPROVED | ARAYMOND |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 01/20/2006 | CANCELLED BY APPLICANT | ARAYMOND |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/22/2005 | APPROVED | JMCGOWEN |
| LINTEL | 12/05/2005 | APPROVED | ARAYMOND |
| LINTEL | 12/02/2005 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: 1. MISSING DOWELS 2. MISSING CELLS PER BOND BEAM TRANSITION DETAIL | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 11/21/2005 | APPROVED | ARAYMOND |
| MONOLITHIC SLAB INSPECTION/SLAB | 11/18/2005 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: MISSING STEEL, NOT READY | |||
| FIRST ROUGH PLUMBING INSPECTION | 11/16/2005 | APPROVED | ARAYMOND |
| FIRST ROUGH PLUMBING INSPECTION | 11/15/2005 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: THIS IS A REINSPECTION PREVIOUS NOTICE INCOMPLETE. | |||
| FIRST ROUGH PLUMBING INSPECTION | 11/14/2005 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: no test pressure on waste system |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/22/2005 | 12/22/2005 |
| Note: Released By: LWOODROME Revision: Window and door buck attachment | |||
| BLD | COMPLETE | 11/30/2005 | 12/01/2005 |
| Note: Released By: LWOODROME Revision: Truss repair and rebar repair | |||
| SWMD | COMPLETE | 09/19/2005 | 09/19/2005 |
| Note: Released By: WKINELL | |||
| BLD | COMPLETE | 09/09/2005 | 09/12/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R> | |||
| BLD | HOLD | 08/09/2005 | 08/18/2005 |
| Note: Held By: FREODICA Misc. details sheet ( porch, entry, wall sections, gable bracing, etc.) is missing in the submitted dwg. set. | |||
| ZON | COMPLETE | 07/28/2005 | 08/09/2005 |
| Note: Released By: HHERKERT | |||
| ZON | HOLD | 07/28/2005 | |
| Note: Held By: HHERKERT NEED LANDSCAPE PLAN SQUARE FT TABULATION INCORRECT NEED SQ FT OF LOT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤684.00 | 05/24/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 05/24/2006 |
| REINSPECTION FEE | ¤40.00 | 05/24/2006 |
| REINSPECTION FEE | ¤40.00 | 05/24/2006 |
| REINSPECTION FEE | ¤40.00 | 05/24/2006 |
| REINSPECTION FEE | ¤40.00 | 05/24/2006 |
| REINSPECTION FEE | ¤40.00 | 05/24/2006 |
| REINSPECTION FEE | ¤40.00 | 05/24/2006 |
| REVISION | ¤40.00 | 05/24/2006 |
| REVISION | ¤40.00 | 05/24/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 05/24/2006 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 10/21/2005 |
| ADMIN FEE | ¤20.00 | 10/21/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 10/21/2005 |
| BUILDING CODE ADMIN FUND | ¤12.23 | 10/21/2005 |
| ELECTRIC FEE | ¤126.00 | 10/21/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 10/21/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 10/21/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 10/21/2005 |
| MECHANICAL FEE | ¤126.00 | 10/21/2005 |
| PERMIT FEE | ¤624.00 | 10/21/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 10/21/2005 |
| PLAN CHECK FEE | ¤64.00 | 10/21/2005 |
| PLUMBING FEE | ¤126.00 | 10/21/2005 |
| RADON FEE | ¤12.23 | 10/21/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,173.84 |