I want to search for...
Permit #2005070740
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-01140-0040 |
| CONDITIONED SPACE: 2157 sqft |
| GARAGE: 445 sqft |
| OPENED PORCH (WITH ROOF) : 215 sqft |
| OPENED PORCH (WITH ROOF) : 73 sqft |
| Total Square Footage: 2890 sqft |
| Block: 0114 |
| Subdivision: - |
| Job Phone: (386) 586-1109 |
| Location Address: 10 LEWIS SHIRE PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/10/2005 |
| NOC: RECORDED |
| Applicant name: GREGORY THOMAS BEATY |
| Owner: AFFORDABLE FLORIDA HOMES, INC |
|
Address 4070 MONZA DRIVE NEW SMYRA BEACH, FL 32168 |
| Lot: 040 |
| Contracted Stated Job Value: ¤167,024.00 |
| Job Description: RESIDENTIAL SINGLE FAMILY HOME |
| Type: CN |
Contractor
AFFORDABLE FLORIDA HOMES, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
4070 Monza Dr. NEW SMYRNA BEACH, FL 32168 |
CBC026117 (Exp: 08/31/2010) | (386)423-6670 | (866)721-6888 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 02/24/2006 | FINAL APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION. MISSING TERMITE STICKER AT ELECTRICAL PANEL/ LEFT NOTE ON PLACARD AS A REMINDER TO ADD THIS TO THE PANEL | |||
| UTILITY COMPANY FINAL | 02/22/2006 | APPROVED | RANDRADE |
| FINAL COMPLETE BUILDING INSPECTION | 02/22/2006 | CANCELLED BY APPLICANT | MMOORE |
| RESIDENTIAL EARLY POWER | 02/22/2006 | APPROVED | MMOORE |
| STORMWATER FINAL INSPECTION | 02/20/2006 | APPROVED | BFCHAMBERLAIN |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 02/17/2006 | APPROVED | RANDRADE |
| STORMWATER FINAL INSPECTION | 02/16/2006 | Disapproved -FEE REQUIRED | BFCHAMBERLAIN |
| Note: straw and seed exposed earth on adjacent left and rear property lines | |||
| DRIVEWAY | 01/17/2006 | APPROVED | BFCHAMBERLAIN |
| LATH /BRICK FLASHING | 12/07/2005 | APPROVED | MM |
| INSULATION INSPECTION | 11/22/2005 | APPROVED - AS NOTED | MMOORE |
| Note: THIS IS A REINSPECTION...dryer vent below roof plywood.....rechecked on 11-23-05/ ok m.m. | |||
| INSULATION INSPECTION | 11/21/2005 | Disapproved -FEE REQUIRED | MMOORE |
| Note: not all holes foamed at firestop entry atra at wires and right wall | |||
| ALL ROUGH | 11/16/2005 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION MISSING WIRE NUTS ON SOME GROUNDS IN BOXES AND PIGTAILS TO GROUND SWITCHES IN PLASTIC BOXES. NO PLANS | |||
| ALL ROUGH | 11/15/2005 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: no plans in the box | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/10/2005 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/01/2005 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. BOTH TRUSS JACKS JO3's IN GARAGE/ STRAPS BENT UNDER TRUSS/ FIX 2. ALL TRUSSES WITH STRAPS BENT OVER OR OFF TO THE SIDES OF TRUSSES TO BE FIXED 3. EXPOSE TAPCONS HOLDING ARCHES 4. VAPOR BARRIER REQUIRED AT ALL TRUSSES AT LIVING ROOM WALL, DINETTE WALL 5. TO9 DINETTE WALL STRAP BENT UNDER/ CHECK ALL STRAPS 6. T-43 BACK-WALL/ CHECK UP-LIFT/ ONLY ONE STRAP | |||
| LINTEL | 10/20/2005 | CANCELLED BY APPLICANT | MMOORE |
| LINTEL | 10/19/2005 | APPROVED | MMOORE |
| MONOLITHIC SLAB INSPECTION/SLAB | 10/04/2005 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 09/27/2005 | APPROVED | ARITTER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 08/04/2005 | 08/09/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| ZON | COMPLETE | 07/29/2005 | 08/04/2005 |
| Note: Released By: HHERKERT | |||
| SWMD | COMPLETE | 08/02/2005 | |
| Note: Released By: WKINELL | |||
| ZON | HOLD | 07/29/2005 | |
| Note: Held By: HHERKERT NEED ADDT'L LANDSCAPE FACING LEWIS SHIRE WAY, CORNER LOT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 02/27/2006 |
| REINSPECTION FEE | ¤40.00 | 02/27/2006 |
| REINSPECTION FEE | ¤40.00 | 02/27/2006 |
| REINSPECTION FEE | ¤40.00 | 02/27/2006 |
| REINSPECTION FEE | ¤40.00 | 02/27/2006 |
| REINSPECTION FEE | ¤40.00 | 02/27/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 02/27/2006 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 08/10/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 08/10/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/10/2005 |
| ADMIN FEE | ¤20.00 | 08/10/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 08/10/2005 |
| BUILDING CODE ADMIN FUND | ¤14.45 | 08/10/2005 |
| ELECTRIC FEE | ¤131.40 | 08/10/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 08/10/2005 |
| MECHANICAL FEE | ¤131.40 | 08/10/2005 |
| PERMIT FEE | ¤659.10 | 08/10/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 08/10/2005 |
| PLAN CHECK FEE | ¤67.60 | 08/10/2005 |
| PLUMBING FEE | ¤131.40 | 08/10/2005 |
| RADON FEE | ¤14.45 | 08/10/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,429.18 |