Permit #2005080144

Permit Details

Status: COED

Parcel Id: 07-11-31-7016-00100-0660
CONDITIONED SPACE: 1945 sqft
GARAGE: 547 sqft
OPENED PORCH (WITH ROOF) : 93 sqft
OPENED PORCH (WITH ROOF) : 29 sqft
Total Square Footage: 2614 sqft
Block: 0010
Subdivision: -
Job Phone: (386) 445-1342
Location Address: 20 CHERRYTREE CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/30/2005
NOC: RECORDED
Applicant name: GIULIO LANCIA
Owner: FICK DONALD M &

Address

CAROLINE

PARMA, OH 44134

Address

5240 SEQUOIA DRIVE

PARMA, OH 44134

Lot: 660
Contracted Stated Job Value: ¤117,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

LANCIA CUSTOM HOMES, INC.
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 351602

FLAGLER BEACH , FL 32136

CBC047064 (Exp: 08/31/2018) (386) 445-1342 (386)445-7509

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 04/26/2006 FINAL APPROVED JGIBSON
UTILITY COMPANY FINAL 04/11/2006 APPROVED RANDRADE
STORMWATER FINAL INSPECTION 04/10/2006 APPROVED BFCHAMBERLAIN
PRE DRIVEWAY 03/15/2006 APPROVED BFCHAMBERLAIN
INSULATION INSPECTION 01/12/2006 APPROVED ARAYMOND
ALL ROUGH 01/10/2006 APPROVED JMCGOWEN
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 12/12/2005 APPROVED - AS NOTED ARAYMOND
Note: MISSED FILLED CELL LEFT, CHECK AT ROUGHS.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 12/09/2005 CANCELLED BY APPLICANT AIRS WEB
LINTEL 11/15/2005 APPROVED ARAYMOND
Note: THIS IS A REINSPECTION
LINTEL 11/14/2005 Disapproved -FEE REQUIRED ARAYMOND
Note: MISSED CALLS AT ENTRY.
MONOLITHIC SLAB INSPECTION/SLAB 10/20/2005 APPROVED JMCGOWEN
FIRST ROUGH PLUMBING INSPECTION 10/17/2005 APPROVED JMCGOWEN

Review History

Department Status Date In Date Out
BLD COMPLETE 08/29/2005 08/29/2005
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 08/24/2005 08/26/2005
Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. Provide detail for infill of masonry opening above arch windows. 2. Revise gable end detail for a flat ceiling. The detail provided is for a vaulted ceiling which does not apply and if it did apply to this project it would not be acceptable. 3. The step bond beam detail indicates that there are two vertical cells side by side. The plans do not show double cells at all stepped bond beam locations such as at the side wall of the Master Bath and rear wall of Bedroom #2. 4. Provide detail indicating framing to be used and how framing is to be fastened to masonry for the arches at front entry and rear porch as well as the roof returns at Bedroom #3. 5. Provide a glass block installation detail. 6. Provide a lintel schedule. Indicate type, size, reinforcing type size and location for all masonry opening. The floor plan indicates only some of the lintels and the wall section has only generic information. *Ideally the floor or roof framing plan(s) would contain a symbol at each opening that corresponded to a lintel schedule. I have attached a copy of a "SAMPLE" lintel schedule that is acceptable.
ZON COMPLETE 08/09/2005 08/24/2005
Note: Released By: HHERKERT
SWMD COMPLETE 08/04/2005 08/16/2005
Note: Released By: WKINELL
ZON HOLD 08/04/2005 08/09/2005
Note: Held By: BWRY NEED LANDSCAPE PLAN

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 04/26/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 08/30/2005
STORM WATER PERMIT FEES ¤80.00 08/30/2005
TRANSPORTATION IMPACT FEE3/RES ¤2,885.00 08/30/2005
ADMIN FEE ¤20.00 08/30/2005
ARC HOUSE REVIEW ¤125.00 08/30/2005
BUILDING CODE ADMIN FUND ¤13.07 08/30/2005
ELECTRIC FEE ¤123.00 08/30/2005
FIRE RES IMPACT FEE 4-1-05 ¤173.47 08/30/2005
MECHANICAL FEE ¤123.00 08/30/2005
PERMIT FEE ¤604.50 08/30/2005
PARKS IMPACT FEE 11-2-04 ¤1,120.91 08/30/2005
PLAN CHECK FEE ¤62.00 08/30/2005
PLUMBING FEE ¤123.00 08/30/2005
RADON FEE ¤13.07 08/30/2005