I want to search for...

Permit #2005080160

Permit Details

Status: COED

Parcel Id: 07-11-31-7060-00040-0090
CONDITIONED SPACE: 2298 sqft
GARAGE: 437 sqft
OPENED PORCH (WITH ROOF) : 286 sqft
OPENED PORCH (WITH ROOF) : 72 sqft
Total Square Footage: 3093 sqft
Block: 0004
Subdivision: -
Job Phone: (386)437-5782
Location Address: 72 SLUMBER MEADOW TR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/30/2005
NOC: RECORDED
Applicant name: SANDRA LEE FRENCH
Owner: MIKE AND JOSEPHINE SIKORA

Address

PO BOX 350151

PALM COAST, FL 32135

Lot: 090
Contracted Stated Job Value: ¤160,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SANDEX HOMES
Status Location Address State License Number Phone Fax
CANCEL

27 EGAN DR

PALM COAST, FL

CRC1327302 (Exp: 09/30/2008) (386)437-5782 (386)437-5782

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 06/30/2006 FINAL APPROVED DROCKWELL
STORMWATER FINAL INSPECTION 06/28/2006 APPROVED - AS NOTED GLALIMA
Note: 14 FEET ROAD DAMAGE = 212.00
UTILITY COMPANY FINAL 06/27/2006 APPROVED MBACON
STORMWATER FINAL INSPECTION 06/27/2006 Disapproved -FEE REQUIRED GLALIMA
Note: 14' FEET ROAD DAMAGE , REMOVE DUMPSTER , SEED AND STRAW.
PRE DRIVEWAY 06/15/2006 APPROVED GLALIMA
LATH /BRICK FLASHING 04/03/2006 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
LATH /BRICK FLASHING 03/30/2006 Disapproved -FEE REQUIRED DROCKWELL
Note: See return left side of house no dry-in or lath
LATH /BRICK FLASHING 03/29/2006 CANCELLED BY APPLICANT DROCKWELL
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/21/2006 APPROVED - AS NOTED JGIBSON
Note: Change in elevation of roof OK.
INSULATION INSPECTION 02/27/2006 APPROVED DROCKWELL
INSULATION INSPECTION 02/24/2006 CANCELLED BY APPLICANT AIRS WEB
Note: THIS IS A REINSPECTION
INSULATION INSPECTION 02/08/2006 Disapproved -FEE REQUIRED DROCKWELL
Note: Draftstop dryer vent/Washer vent/2" bath vent
ALL ROUGH 02/03/2006 APPROVED DROCKWELL
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 12/30/2005 APPROVED DROCKWELL
Note: All 2x attached to masonry to be tapconned
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 12/29/2005 CANCELLED BY INSPECTOR DROCKWELL
LINTEL 11/09/2005 APPROVED DROCKWELL
MONOLITHIC SLAB INSPECTION/SLAB 10/19/2005 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB INSPECTION/SLAB 10/17/2005 Disapproved -FEE REQUIRED DROCKWELL
Note: Missing many dowels
MONOLITHIC SLAB INSPECTION/SLAB 10/05/2005 Disapproved -FEE REQUIRED DROCKWELL
Note: Remove steel re-dig footers
FIRST ROUGH PLUMBING INSPECTION 10/03/2005 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
BLD COMPLETE 03/14/2006 03/17/2006
Note: Released By: LWOODROME Revision: Trusses @ garage
BLD HOLD 02/24/2006 02/28/2006
Note: Held By: LWOODROME PLAN REVIEW COMMENTS: " Clarify the scope of this proposed revision. Elevation of the garage, on the approved plan shows a hip roof. The revision detail looks like a gable end, without any reference to which trusses are affected by this revision. Verify that the original truss design will support this added load and provide additional drawing(s) and/or information, with sufficient detail(s) for review, construction and inspection of this revision. Larry Woodrome, CBO Chief Plans Examiner City of Palm Coast 386-986-3786
BLD COMPLETE 12/22/2005 12/22/2005
Note: Released By: LWOODROME Revision: Truss connector schedule, truss repair
BLD COMPLETE 08/12/2005 08/12/2005
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R>
URB COMPLETE 08/09/2005 08/12/2005
Note: Released By: CGOEWEY
URB COMPLETE 08/08/2005 08/09/2005
Note: Released By: IVAZQUEZ Held By: CGOEWEY 8/9/05 (CG) WHAT ARE YOU SAVING?
SWMD COMPLETE 08/04/2005 08/24/2005
Note: Released By: LAPTEKAR made copies of site plan out of main file
ZON COMPLETE 08/04/2005 08/04/2005
Note: Released By: IVAZQUEZ Held By: DCHAUDOIN NEED COLOR AND MATERIAL SHEET
ZON COMPLETE 08/04/2005 08/08/2005
Note: Released By: HHERKERT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤212.00 06/30/2006
REINSPECTION FEE ¤40.00 06/30/2006
REINSPECTION FEE ¤40.00 06/30/2006
REINSPECTION FEE ¤40.00 06/30/2006
REINSPECTION FEE ¤40.00 06/30/2006
REVISION ¤40.00 06/30/2006
REVISION ¤40.00 06/30/2006
STORMWATER REINSPECTION FEE ¤35.00 06/30/2006
TRANSPORTATION IMPACT FEE3/RES ¤2,885.00 09/30/2005
ADMIN FEE ¤20.00 09/30/2005
ARC HOUSE REVIEW ¤125.00 09/30/2005
BUILDING CODE ADMIN FUND ¤15.47 09/30/2005
ELECTRIC FEE ¤137.40 09/30/2005
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 09/30/2005
STORM WATER PERMIT FEES ¤80.00 09/30/2005
FIRE RES IMPACT FEE 4-1-05 ¤173.47 09/30/2005
MECHANICAL FEE ¤137.40 09/30/2005
PERMIT FEE ¤698.10 09/30/2005
PARKS IMPACT FEE 11-2-04 ¤1,120.91 09/30/2005
PLAN CHECK FEE ¤71.60 09/30/2005
PLUMBING FEE ¤137.40 09/30/2005
RADON FEE ¤15.47 09/30/2005
Fees Total Due: ¤0.00 Total Paid: ¤9,704.22