I want to search for...
Permit #2005080178
Permit Details
Status: COED
| CONDITIONED SPACE: 3557 sqft |
| GARAGE: 687 sqft |
| OPENED PORCH (WITH ROOF) : 236 sqft |
| OPENED PORCH (WITH ROOF) : 392 sqft |
| OPENED PORCH (WITH ROOF) : 53 sqft |
| PATIO/DECK (NO ROOF) : 116 sqft |
| Total Square Footage: 5041 sqft |
| Subdivision: 2070 - Grand Haven North Phase 1 @ Grand Haven |
| Job Phone: (386) 445-4747 |
| Location Address: 7 WATERVIEW DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/26/2005 |
| NOC: RECORDED |
| Applicant name: WILLIAM VALENTINE GROFF |
| Owner: JOSEPH A HANZEL JR & |
|
Address JUDY M BEDELL (TRUSTEES PALM COAST, FL 32137 |
|
Address 2 CHINOOK COURT PALM COAST, FL 32137 |
| Lot: 31 |
| Contracted Stated Job Value: ¤450,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
COUNTRY CLUB HOMES OF FLORIDA, INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
4440 N. Oceanshore Blvd Palm Coast, FL 32137 |
SUITE 101 Palm Coast, FL 32137 |
CRC043737 (Exp: 08/31/2012) | (386) 445-4747 | (386)445-5955 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 09/29/2006 | FINAL APPROVED | JGIBSON |
| UTILITY COMPANY FINAL | 09/27/2006 | APPROVED | JSHEVLIN |
| Note: THIS IS A REINSPECTION WILLIAM CALLED TO SCHEDULE A UTILITY AND STORMWATER FINAL. HE SAID IT TOLD HIM THERE WAS NO NOC ON RECORD. I CHECKED ON BASE AND THERE WAS ONE ON FILE. I SCHEDULED THOSE INSPECTIONS FOR 9/27/06 | |||
| STORMWATER FINAL INSPECTION | 09/27/2006 | APPROVED | DRANDALL |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 09/22/2006 | Disapproved - NO FEE | JSHEVLIN |
| Note: FAILED, UNABLE TO LOCATE 6" CLEAN OUT | |||
| STORMWATER FINAL INSPECTION | 09/19/2006 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: seed & straw exposed earth right side.....remove construction debris from right adj. property .....repair chips in curb at driveway [marked with paint ] | |||
| RESIDENTIAL EARLY POWER | 08/18/2006 | APPROVED | KSAMPICO |
| INSULATION INSPECTION | 05/24/2006 | APPROVED | CMINI |
| GAS ROUGH | 05/19/2006 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| GAS ROUGH | 05/18/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: gas pipe must be bonded to house grounding system | |||
| ALL ROUGH | 05/17/2006 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 05/16/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: Strap wires at panel. Firestop missing. Wirestraps missing - must be within 8" of a device box. Holdoffs missing - romex must be held 1 1/4" away from all members. Need water test on bathtub. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/15/2006 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION.HAVE REVISION FOR CHANGE OF BLOCK WALL TO FRAMING AND TIE DOWNS BY INSULATION. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/05/2006 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: must hqve truss plans on job. plan calls for 2x4 and 2x6 wall 12oc. wall post is not to plans. (s1-1) revise drawings to show what is existing. down cells are ok.THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/21/2006 | CANCELLED BY APPLICANT | JMCGOWEN |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 03/02/2006 | APPROVED | LAPTEKAR |
| LINTEL | 02/22/2006 | APPROVED | TOUTLAND |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 02/21/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: THIS IS A REINSPECTION rods, and fill cells not to plan | |||
| LINTEL | 02/20/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: replace missing dowels Not ready | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 02/09/2006 | APPROVED | JMCGOWEN |
| FIRST ROUGH PLUMBING INSPECTION | 02/02/2006 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| RETAINING WALL | 01/18/2006 | APPROVED | JMCGOWEN |
| STEM FOOTING FOUNDATION | 01/13/2006 | APPROVED | JMCGOWEN |
| FIRST ROUGH PLUMBING INSPECTION | 01/13/2006 | CANCELLED BY APPLICANT | JMCGOWEN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 05/22/2006 | 05/23/2006 |
| Note: Released By: LWOODROME Revision: Microlam beam and connector | |||
| BLD | COMPLETE | 04/19/2006 | 04/20/2006 |
| Note: Released By: LWOODROME Revision: Truss repair | |||
| BLD | COMPLETE | 09/22/2005 | 09/23/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R> | |||
| BLD | HOLD | 09/03/2005 | 09/13/2005 |
| Note: Held By: FREODICA 1. Provide lintel schedule for all windows/doors opening. 2. Provide beam transition detail and wall section. 3. Referenced drawing S2.1 is missing in the submitted drawing set, submit (2) copies. | |||
| URB | COMPLETE | 08/30/2005 | 09/12/2005 |
| Note: Released By: CGOEWEY | |||
| URB | HOLD | 08/25/2005 | 08/30/2005 |
| Note: Held By: CGOEWEY 8/30/05 (BB) REVISE TREE SURVEY TO INDICATE THE C & D TREES, ACTUALLY 5 TREES, 15", 12", 11", 8", 8" NO BARRICADES UP | |||
| SWMD | COMPLETE | 08/05/2005 | 08/18/2005 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 08/05/2005 | 08/25/2005 |
| Note: Released By: HHERKERT | |||
| ZON | HOLD | 08/04/2005 | 08/05/2005 |
| Note: Held By: HHERKERT need breakdown of square foot tabulation, to include, living area, garage, cabana and lanai |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 10/02/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 10/02/2006 |
| REINSPECTION FEE | ¤40.00 | 10/02/2006 |
| REINSPECTION FEE | ¤40.00 | 10/02/2006 |
| REINSPECTION FEE | ¤40.00 | 10/02/2006 |
| REINSPECTION FEE | ¤40.00 | 10/02/2006 |
| REINSPECTION FEE | ¤40.00 | 10/02/2006 |
| REVISION | ¤40.00 | 10/02/2006 |
| REVISION | ¤40.00 | 10/02/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 10/02/2006 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 09/26/2005 |
| TRANSPORTATION IMPACT FEE3/RES | (¤2,885.00) | 09/26/2005 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 09/26/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 09/26/2005 |
| SCHOOL BOARD IMPACT FEE RES | (¤3,600.00) | 09/26/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 09/26/2005 |
| STORM WATER PERMIT FEES | (¤80.00) | 09/26/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/26/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/26/2005 |
| ADMIN FEE | (¤20.00) | 09/26/2005 |
| ADMIN FEE | ¤20.00 | 09/26/2005 |
| ADMIN FEE | ¤20.00 | 09/26/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 09/26/2005 |
| ARC HOUSE REVIEW | (¤125.00) | 09/26/2005 |
| BUILDING CODE ADMIN FUND | (¤25.21) | 09/26/2005 |
| BUILDING CODE ADMIN FUND | ¤25.21 | 09/26/2005 |
| BUILDING CODE ADMIN FUND | ¤25.21 | 09/26/2005 |
| ELECTRIC FEE | ¤300.00 | 09/26/2005 |
| ELECTRIC FEE | (¤300.00) | 09/26/2005 |
| ELECTRIC FEE | ¤300.00 | 09/26/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 09/26/2005 |
| FIRE RES IMPACT FEE 4-1-05 | (¤173.47) | 09/26/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 09/26/2005 |
| MECHANICAL FEE | (¤300.00) | 09/26/2005 |
| MECHANICAL FEE | ¤300.00 | 09/26/2005 |
| MECHANICAL FEE | ¤300.00 | 09/26/2005 |
| PERMIT FEE | ¤1,755.00 | 09/26/2005 |
| PERMIT FEE | (¤1,755.00) | 09/26/2005 |
| PERMIT FEE | ¤1,755.00 | 09/26/2005 |
| PARKS IMPACT FEE 11-2-04 | (¤1,120.91) | 09/26/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 09/26/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 09/26/2005 |
| PLAN CHECK FEE | ¤180.00 | 09/26/2005 |
| PLAN CHECK FEE | (¤180.00) | 09/26/2005 |
| PLAN CHECK FEE | ¤180.00 | 09/26/2005 |
| PLUMBING FEE | (¤300.00) | 09/26/2005 |
| PLUMBING FEE | ¤300.00 | 09/26/2005 |
| PLUMBING FEE | ¤300.00 | 09/26/2005 |
| RADON FEE | ¤25.21 | 09/26/2005 |
| RADON FEE | (¤25.21) | 09/26/2005 |
| RADON FEE | ¤25.21 | 09/26/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤11,159.80 |