I want to search for...
Permit #2005080327
Permit Details
Status: COED
| Parcel Id: 07-11-31-7025-00080-0030 |
| CONDITIONED SPACE: 2830 sqft |
| GARAGE: 666 sqft |
| OPENED PORCH (WITH ROOF) : 38 sqft |
| PATIO/DECK (NO ROOF) : 100 sqft |
| Total Square Footage: 3634 sqft |
| Block: 0008 |
| Subdivision: 1228 - SOUTHWEST QUADRANT |
| Job Phone: (386)274-7190 |
| Location Address: 281 PARKVIEW DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/25/2005 |
| NOC: RECORDED |
| Applicant name: JOHN DAVID MOLYNEAUX |
| Owner: KB HOME |
|
Address 735 FENTRESS BLVD DAYTONA BEACH, FL 32114 |
| Lot: 030 |
| Contracted Stated Job Value: ¤180,990.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
KB HOME ORLANDO, LLC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
9102 SOUTHPARK CENTER LOOP # 200 ORLANDO, FL 32819 |
CBC051212 (Exp: 08/31/2010) | (407)587-3531 | (407)587-2333 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 04/05/2006 | FINAL APPROVED | ARITTER |
| STORMWATER FINAL INSPECTION | 03/27/2006 | APPROVED | BFCHAMBERLAIN |
| Note: Repair crack in sidewalk in front of power pole at left front | |||
| UTILITY COMPANY FINAL | 03/22/2006 | APPROVED | RANDRADE |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 03/21/2006 | Disapproved - NO FEE | RANDRADE |
| Note: failed, no sod | |||
| DRIVEWAY | 03/08/2006 | APPROVED | BFCHAMBERLAIN |
| Note: THIS IS A REINSPECTION | |||
| RESIDENTIAL EARLY POWER | 03/07/2006 | APPROVED | TOUTLAND |
| DRIVEWAY | 03/03/2006 | Disapproved -FEE REQUIRED | DSCHRAGER |
| Note: - 50% of pipe must be in compacted soil. - Left side of pipe loose. | |||
| LATH /BRICK FLASHING | 01/27/2006 | APPROVED | JMCGOWEN |
| INSULATION INSPECTION | 01/23/2006 | APPROVED | ARITTER |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 01/18/2006 | Disapproved - NO FEE | ARAYMOND |
| Note: THIS IS A REINSPECTION fire stop staircase, seal all penitrations | |||
| INSULATION INSPECTION | 01/13/2006 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: energy sheet must be on job for inspection | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/10/2006 | APPROVED | ARITTER |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 01/10/2006 | APPROVED - AS NOTED | ARITTER |
| Note: exhaust fan in powder room not connected to outside Check at Insulation | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/05/2006 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: 1. load path incomplete front 2nd floor over garage at still plate 2. engineering to repair to8 | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/13/2005 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: 1. SHEATHING UNSUPPORTED AND LESS THAN 24" AT FRONT OVERHANG MUST BE BLOCKED. 2.STRAP BRACKET FGTR ON T100 NOT PROPERLY BOLTED OR HOLLOW BLOCK (CMU). mISSING HGT-4. 3. MISSING STRAPS ON T20R AND T21R. MISSING BRACE ON T20R. 4. UPSTAIRS BEARING WALL LOAD PATH AND STRAPS MISSING. 5. LOAD PATH ABOVE T100 NOT READY | |||
| LINTEL | 11/14/2005 | APPROVED | ARAYMOND |
| MONOLITHIC SLAB INSPECTION/SLAB | 11/07/2005 | APPROVED | ARAYMOND |
| Note: THIS IS A REINSPECTION NO TOILET FACILITIES | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 11/03/2005 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: 1. MISSING OR INCOMPLETE FOOTER. 2. MISSING COLUMN PAD STEEL. NOT READY | |||
| FIRST ROUGH PLUMBING INSPECTION | 11/01/2005 | APPROVED | ARAYMOND |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/30/2005 | 01/03/2006 |
| Note: Released By: LWOODROME Revision: Girder truss attachment | |||
| BLD | COMPLETE | 12/07/2005 | 12/08/2005 |
| Note: Released By: LWOODROME Revision: Truss repair and LVL attachment | |||
| BLD | COMPLETE | 08/10/2005 | 08/18/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R> | |||
| SWMD | COMPLETE | 08/10/2005 | 08/24/2005 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 08/10/2005 | 08/10/2005 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 05/16/2006 |
| REINSPECTION FEE | ¤40.00 | 05/16/2006 |
| REINSPECTION FEE | ¤40.00 | 05/16/2006 |
| REINSPECTION FEE | ¤40.00 | 05/16/2006 |
| REINSPECTION FEE | ¤40.00 | 05/16/2006 |
| REVISION | ¤40.00 | 05/16/2006 |
| REVISION | ¤40.00 | 05/16/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 05/16/2006 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 08/25/2005 |
| ADMIN FEE | ¤20.00 | 08/25/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 08/25/2005 |
| BUILDING CODE ADMIN FUND | ¤18.17 | 08/25/2005 |
| ELECTRIC FEE | ¤162.00 | 08/25/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 08/25/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/25/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 08/25/2005 |
| MECHANICAL FEE | ¤162.00 | 08/25/2005 |
| PERMIT FEE | ¤858.00 | 08/25/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 08/25/2005 |
| PLAN CHECK FEE | ¤88.00 | 08/25/2005 |
| PLUMBING FEE | ¤162.00 | 08/25/2005 |
| RADON FEE | ¤18.17 | 08/25/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,787.72 |