I want to search for...
Permit #2005080441
Permit Details
Status: COED
| Parcel Id: 07-11-31-7063-00150-0180 |
| CONDITIONED SPACE: 2816 sqft |
| GARAGE: 566 sqft |
| OPENED PORCH (WITH ROOF) : 212 sqft |
| OPENED PORCH (WITH ROOF) : 66 sqft |
| Total Square Footage: 3660 sqft |
| Block: 0015 |
| Subdivision: - |
| Job Phone: (386) 672-8285 |
| Location Address: 11 ZONAL GERANIUM CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/14/2005 |
| NOC: RECORDED |
| Applicant name: JOSEPH TODD VANACORE |
| Owner: HERNANDEZ PHILIP & |
|
Address DORIS HARRISON, NJ 07029 |
|
Address 523 CROSS STREET HARRISON, NJ 07029 |
| Lot: 180 |
| Contracted Stated Job Value: ¤180,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
VANACORE CONSTRUCTION INC.
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
1451 N US HIGHWAY 1 Ormond Beach, FL 32174 |
SUITE 13 Ormond Beach, FL 32174 |
CBC058991 (Exp: 08/31/2024) | (386) 672-8285 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 06/08/2006 | FINAL APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 06/07/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: Need 3' working clearance at a/c disconnect. | |||
| STORMWATER FINAL INSPECTION | 06/02/2006 | APPROVED - AS NOTED | GLALIMA |
| Note: 44 FEET ROAD DAMAGE = 452.00 CAN NOT HAVE A 1 1/2 LIP ON END OF DRIVEWAY | |||
| UTILITY COMPANY FINAL | 05/26/2006 | APPROVED | RANDRADE |
| Note: INSPECTOR WAS RICK DRIGGERS | |||
| DRIVEWAY | 05/10/2006 | APPROVED | GLALIMA |
| RESIDENTIAL EARLY POWER | 04/10/2006 | APPROVED | PGALLMANN |
| TEMPORARY POLE | 02/17/2006 | APPROVED | DROCKWELL |
| Note: called fpl at 4:25 Susan | |||
| LATH /BRICK FLASHING | 02/07/2006 | APPROVED | JGIBSON |
| INSULATION INSPECTION | 02/03/2006 | APPROVED | DROCKWELL |
| ALL ROUGH | 01/30/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 01/18/2006 | CANCELLED BY APPLICANT | JGIBSON |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/21/2005 | APPROVED | DROCKWELL |
| LINTEL | 11/15/2005 | APPROVED | DROCKWELL |
| LINTEL | 11/14/2005 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Radious steel not in in master bath area. | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 10/28/2005 | APPROVED | JGIBSON |
| FIRST ROUGH PLUMBING INSPECTION | 10/27/2005 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/20/2005 | 12/22/2005 |
| Note: Released By: LWOODROME Revision: Window and door buck attachment | |||
| BLD | COMPLETE | 09/09/2005 | 09/09/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| URB | COMPLETE | 08/15/2005 | 08/15/2005 |
| Note: Released By: CGOEWEY | |||
| BLD | HOLD | 08/15/2005 | 08/18/2005 |
| Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. Sheet 2 appears to be missing. Please provide if there is indeed a sheet 2. 2. Provide a foundation plan. 3. Provide a truss layout drawing, include a connector schedule. Truss layout shall indicate loading for a tile roof. 4. Revise sheet 1 roof information as required to provide a tile roof. 5. Provide a lintel schedule, indicate whether lintels for all masonry openings will be: a. Unfilled or Filled. b. Unreinforced or Reinforced. c. If reinforced, provide reinforcing size, quantity and location. 6. The spacing of downcells at the Master Bedroom exterior wall appears to exceed code limitations, please review and revise as required. Indicate a maximum spacing of downcells on the downcell note. 7. The bond beam transistion detail shows a double downcell, however the floor plan does not show double downcells at all areas where there is a change in bond beam elevation. Review locations of downcells and revise as required. 8. Provide a wall section at the two-story area, indicate all components, fastening and connectors used as well as floor sheathing type, grade and thickness. | |||
| SWMD | COMPLETE | 08/12/2005 | 08/29/2005 |
| Note: Released By: WKINELL | |||
| ZON | COMPLETE | 08/12/2005 | 08/12/2005 |
| Note: Released By: BWRY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤452.00 | 06/08/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 06/08/2006 |
| REINSPECTION FEE | ¤40.00 | 06/08/2006 |
| REINSPECTION FEE | ¤40.00 | 06/08/2006 |
| REVISION | ¤40.00 | 06/08/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 09/14/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/14/2005 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 09/14/2005 |
| ADMIN FEE | ¤20.00 | 09/14/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 09/14/2005 |
| BUILDING CODE ADMIN FUND | ¤18.30 | 09/14/2005 |
| ELECTRIC FEE | ¤160.80 | 09/14/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 09/14/2005 |
| MECHANICAL FEE | ¤160.80 | 09/14/2005 |
| PERMIT FEE | ¤850.20 | 09/14/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 09/14/2005 |
| PLAN CHECK FEE | ¤87.20 | 09/14/2005 |
| PLUMBING FEE | ¤160.80 | 09/14/2005 |
| RADON FEE | ¤18.30 | 09/14/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,072.78 |