I want to search for...
Permit #2005080555
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-01410-0030 |
| CONDITIONED SPACE: 2641 sqft |
| GARAGE: 895 sqft |
| OPENED PORCH (WITH ROOF) : 374 sqft |
| OPENED PORCH (WITH ROOF) : 27 sqft |
| Total Square Footage: 3937 sqft |
| Block: 0141 |
| Subdivision: - |
| Job Phone: (386) 445-4515 |
| Location Address: 114 ERIC DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/14/2005 |
| NOC: RECORDED |
| Applicant name: GREGORY LEE LE PERA |
| Owner: TERRELL AND ANNE WILLIMS |
|
Address 1 SELENE PLACE PALM COAST, FL 32164 |
| Lot: 030 |
| Contracted Stated Job Value: ¤126,240.00 |
| Job Description: RESIDENTIAL SINGLE FAMILY HOME |
| Type: CN |
Contractor
WAYNE HOMES BY CENTEX
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
385 DOUGLAS AVE ALTAMONTE SPRINGS, FL 32714 |
STE 3000 ALTAMONTE SPRINGS, FL 32714 |
CBC055301 (Exp: 09/30/2008) | (386) 445-4515 | (386)446-6285 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 07/26/2006 | FINAL APPROVED | KSAMPICO |
| STORMWATER FINAL INSPECTION | 07/24/2006 | APPROVED - AS NOTED | GLALIMA |
| Note: THIS IS A REINSPECTION 7 25 / 06 ROAD DAMAGE IS 38 ' FEET = 404.00 | |||
| STORMWATER FINAL INSPECTION | 07/21/2006 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: 38 s. f. road damage remove port o let and regrade and sod area general cleanup and remove orange fence in rear | |||
| UTILITY COMPANY FINAL | 07/10/2006 | APPROVED | TSCHWEERS |
| RESIDENTIAL EARLY POWER | 06/16/2006 | APPROVED | RMARVEL |
| DRIVEWAY | 06/09/2006 | APPROVED | GLALIMA |
| INSULATION INSPECTION | 05/04/2006 | APPROVED | JGIBSON |
| INSULATION INSPECTION | 05/03/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: NEED TO COMPLETELY FIRESTOP AT TOP OF ELECTRICAL PANEL | |||
| ALL ROUGH | 04/28/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 04/25/2006 | APPROVED | CMINI |
| ALL ROUGH | 04/24/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Dryer vent not boxed out, entry window over door not framed, no plans. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/28/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/22/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Header on rear porch not supported on bearing point, missalighned straps, straps missing tap-con, entry straps not in solid blocking, leadger @ entry not bolted, all MGT connections have wedge anchors per Simpson specs must be all-thread rod or machined bolt in top bond beam. | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 02/22/2006 | APPROVED | WKINELL |
| LINTEL | 02/10/2006 | APPROVED | JGIBSON |
| MONOLITHIC SLAB INSPECTION/SLAB | 01/30/2006 | APPROVED | JGIBSON |
| FIRST ROUGH PLUMBING INSPECTION | 01/25/2006 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/09/2005 | 12/12/2005 |
| Note: Released By: LWOODROME Approved for release as noted on plan cover sheet. Review by FR | |||
| ZON | COMPLETE | 12/05/2005 | 12/09/2005 |
| Note: Released By: HHERKERT | |||
| ZON | REJECT | 12/01/2005 | 12/01/2005 |
| Note: Rejected By: DCHAUDOIN Held By: DCHAUDOIN PERMIT IS ON HOLD FOR THE FOLLOWING REASONS: 1. HOME STILL EXCEEDS 35% COVERAGE 2. NEW DRAWINGS DO NOT INCLUDE CALCULATIONS 3. NEED NEW SITE PLAN SHOWING ADDITIONAL SQAURE FOOTAGE | |||
| DSD | COMPLETE | 08/26/2005 | 08/26/2005 |
| Note: Released By: JCALVERT Held By: JCALVERT Dicussing Lot coverage with ray and Doug per new LDC | |||
| SWMD | COMPLETE | 08/16/2005 | 08/22/2005 |
| Note: Released By: WKINELL | |||
| ZON | REJECT | 08/16/2005 | 08/22/2005 |
| Note: Rejected By: HHERKERT exceeds maximum lot coverage of 35% actual is 39% |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤404.00 | 07/27/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 07/27/2006 |
| REINSPECTION FEE | ¤40.00 | 07/27/2006 |
| REINSPECTION FEE | ¤40.00 | 07/27/2006 |
| REINSPECTION FEE | ¤40.00 | 07/27/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 07/27/2006 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 12/14/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 12/14/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/14/2005 |
| ADMIN FEE | ¤20.00 | 12/14/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 12/14/2005 |
| BUILDING CODE ADMIN FUND | ¤19.69 | 12/14/2005 |
| ELECTRIC FEE | ¤195.00 | 12/14/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 12/14/2005 |
| MECHANICAL FEE | ¤195.00 | 12/14/2005 |
| PERMIT FEE | ¤1,072.50 | 12/14/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 12/14/2005 |
| PLAN CHECK FEE | ¤110.00 | 12/14/2005 |
| PLUMBING FEE | ¤195.00 | 12/14/2005 |
| RADON FEE | ¤19.69 | 12/14/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,410.26 |