I want to search for...
Permit #2005080556
Permit Details
Status: COED
| Parcel Id: 07-11-31-7017-00080-0100 |
| Block: 0008 |
| Subdivision: - |
| Job Phone: (386) 672-8285 |
| Location Address: 41 BOTANY LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/14/2005 |
| NOC: RECORDED |
| Applicant name: JOSEPH TODD VANACORE |
| Owner: VERGARA JUSTO E & |
|
Address LUZ Y NILES, IL 60648 |
| Lot: 100 |
| Contracted Stated Job Value: ¤180,000.00 |
| Job Description: REISDENTIAL SINGLE FAMILY HOME |
| Type: CN |
Contractor
VANACORE CONSTRUCTION INC.
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
1451 N US HIGHWAY 1 Ormond Beach, FL 32174 |
SUITE 13 Ormond Beach, FL 32174 |
CBC058991 (Exp: 08/31/2024) | (386) 672-8285 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 05/16/2006 | FINAL APPROVED | JLEVRAULT |
| STORMWATER FINAL INSPECTION | 05/12/2006 | APPROVED - AS NOTED | BFCHAMBERLAIN |
| Note: 25k s.f. road damage......$300 | |||
| UTILITY COMPANY FINAL | 05/09/2006 | APPROVED | RANDRADE |
| RESIDENTIAL EARLY POWER | 04/18/2006 | APPROVED | MMOORE |
| DRIVEWAY | 04/03/2006 | APPROVED | BFCHAMBERLAIN |
| LATH /BRICK FLASHING | 03/06/2006 | APPROVED | MMOORE |
| INSULATION INSPECTION | 02/06/2006 | APPROVED | ARITTER |
| ALL ROUGH | 01/27/2006 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 01/25/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: trusses not grouted | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/23/2006 | APPROVED - AS NOTED | JLEVRAULT |
| Note: THIS IS A REINSPECTION ---------TRUSSES HAVE NOT BEEN GROUTED-------CHECK AT ALL ROUGH. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/04/2006 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: Headers in garage have incorrect straps per plans - circled on plans. Grout under all trusses that are "floating". 2 ply T-24 cut on one end in bath, only one girder truss is bearing on block - provide engineering repair. 2 ply T-23 not nailed per plan. | |||
| LINTEL | 12/12/2005 | APPROVED | MMOORE |
| MONOLITHIC SLAB INSPECTION/SLAB | 11/29/2005 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 11/28/2005 | CANCELLED BY APPLICANT | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 11/22/2005 | APPROVED | JLEVRAULT |
| FIRST ROUGH PLUMBING INSPECTION | 11/21/2005 | CANCELLED BY APPLICANT | JLEVRAULT |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/18/2006 | 01/19/2006 |
| Note: Released By: LWOODROME Revision: Truss repair | |||
| BLD | HOLD | 01/12/2006 | 01/17/2006 |
| Note: Held By: CCOTE Revision: Truss repair sheets were not signed and sealed. Submit signed and sealed sheets. | |||
| BLD | COMPLETE | 12/22/2005 | 12/22/2005 |
| Note: Released By: LWOODROME Revision: window and door buck attachment | |||
| BLD | COMPLETE | 09/09/2005 | 09/09/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | HOLD | 08/24/2005 | 08/25/2005 |
| Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. Provide a bond beam transition detail. 2. The floor plan references details A/5 & B/5 however these details could not be found on sheet 5. Please provide these details. 3. Clarify lintels to be used. The schedule indicates that the lintels are 8x8 and lists the loading for various widths. The window and door schedules however list deeper lintels which would have different loading which is also affected on the reinforcing stated. | |||
| ZON | COMPLETE | 08/22/2005 | 08/24/2005 |
| Note: Released By: HHERKERT | |||
| SWMD | COMPLETE | 08/16/2005 | 08/22/2005 |
| Note: Released By: WKINELL |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤300.00 | 05/18/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 05/18/2006 |
| REINSPECTION FEE | ¤40.00 | 05/18/2006 |
| REINSPECTION FEE | ¤40.00 | 05/18/2006 |
| REVISION | ¤40.00 | 05/18/2006 |
| REVISION | ¤40.00 | 05/18/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 09/14/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/14/2005 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 09/14/2005 |
| ADMIN FEE | ¤20.00 | 09/14/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 09/14/2005 |
| ELECTRIC FEE | ¤138.00 | 09/14/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 09/14/2005 |
| MECHANICAL FEE | ¤138.00 | 09/14/2005 |
| PERMIT FEE | ¤702.00 | 09/14/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 09/14/2005 |
| PLAN CHECK FEE | ¤72.00 | 09/14/2005 |
| PLUMBING FEE | ¤138.00 | 09/14/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,692.38 |