Permit #2005080600
Permit Details
Status: COED
| CONDITIONED SPACE: 16449 sqft |
| GARAGE: 2535 sqft |
| OPENED PORCH (WITH ROOF) : 1158 sqft |
| Total Square Footage: 20142 sqft |
| Subdivision: 2085 - Tidelands at the Village Phase II |
| Job Phone: (407)838-1486 |
| Location Address: 25 RIVERVIEW BEND N |
| Type: BCR - BUILDING COMMERCIAL RESIDENTIAL -CONDO |
| Issue Date: 10/05/2005 |
| NOC: RECORDED |
| Applicant name: RALPH STEPHEN SMITH |
| Owner: CENTEX DESTINATION PROPERTIES |
|
Address 1064 GREENWOOD BLVD SUITE200 LAKE MARY, FL 32746 |
| Contracted Stated Job Value: ¤1,300,000.00 |
| Job Description: BUILDING #01 10 PLEX TOWNHOMES |
| Type: CN |
Contractor
CENTEX DESTINATION PROPERTIES
| Status | Location Address | Mailing Address | State License Number | Phone |
| CANCEL |
1064 GREENWOOD BLVD LAKE MARY, FL 33746 |
SUITE 200 LAKE MARY, FL 32746 |
CGC1506882 (Exp: 09/30/2008) | (407)838-1486 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 05/19/2006 | FINAL APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION secondary main breakers installed | |||
| FINAL COMPLETE BUILDING INSPECTION | 05/17/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: add main breakers to the panels in units. | |||
| FIRE FINAL | 05/12/2006 | APPROVED | JPATTEE |
| UTILITY COMMERCIAL FINAL | 05/09/2006 | APPROVED | RANDRADE |
| UTILITY COMPANY FINAL | 05/09/2006 | APPROVED | RANDRADE |
| ENGINEERING FINAL | 05/05/2006 | APPROVED | WDONGOSKE |
| LANDSCAPE FINAL | 05/03/2006 | APPROVED | WBUTLER |
| COMMERCIAL POWER INSPECTION | 03/10/2006 | APPROVED | TOUTLAND |
| INSULATION INSPECTION | 02/20/2006 | APPROVED | TOUTLAND |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 02/17/2006 | Disapproved -FEE REQUIRED | TOUTLAND |
| Note: not ready | |||
| INSULATION INSPECTION | 02/15/2006 | CANCELLED BY APPLICANT | AIRS WEB |
| ALL ROUGH | 02/14/2006 | APPROVED | TOUTLAND |
| ALL ROUGH | 02/13/2006 | CANCELLED BY APPLICANT | TOUTLAND |
| FIREWALL INSPECTION 3ND ROUGH | 02/07/2006 | APPROVED | JPATTEE |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/02/2006 | APPROVED | TOUTLAND |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/24/2006 | CANCELLED BY APPLICANT | JMCGOWEN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/09/2006 | CANCELLED BY INSPECTOR | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/30/2005 | Disapproved -FEE REQUIRED | TOUTLAND |
| Note: COREY WAS TO SET UP AN APPOINTMENT WITH PLANS ON SITE. | |||
| ALL ROUGH | 12/21/2005 | CANCELLED BY INSPECTOR | TOUTLAND |
| SECOND ROUGH PLUMBING INSPECTION | 12/21/2005 | CANCELLED BY INSPECTOR | TOUTLAND |
| LINTEL | 12/19/2005 | APPROVED | TOUTLAND |
| MONOLITHIC SLAB INSPECTION/SLAB | 12/07/2005 | APPROVED | TOUTLAND |
| TEMPORARY POLE | 11/21/2005 | APPROVED | JMCGOWEN |
| Note: LIBBY - SUSAN - 9:00 / 11-22-05 | |||
| LINTEL | 11/14/2005 | APPROVED | TOUTLAND |
| Note: THIS IS A REINSPECTION | |||
| POURED CELL | 11/14/2005 | APPROVED | TOUTLAND |
| POURED CELL | 11/10/2005 | CANCELLED BY INSPECTOR | ECOYNE |
| Note: Joe M cancelled inspection should be lintel insp | |||
| LINTEL | 11/10/2005 | Disapproved - NO FEE | JMCGOWEN |
| Note: MANY CORNER BEND RODS MISSING IN FIRST AND SECOND COURSE | |||
| FLOOD ZONE 'A' ELEVATION CERTIFICATE APPROVAL | 11/10/2005 | APPROVED | CBENTLEY |
| Note: approval given prior to elevation certificate. Letter of liability given and certificate will be forwarded next week | |||
| POURED CELL | 11/09/2005 | CANCELLED BY INSPECTOR | ECOYNE |
| Note: need elevation certificate first by Joe McGowen | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 10/25/2005 | APPROVED | JMCGOWEN |
| STEM FOOTING FOUNDATION | 10/24/2005 | CANCELLED BY APPLICANT | TOUTLAND |
| FIRST ROUGH PLUMBING INSPECTION | 10/21/2005 | APPROVED | JMCGOWEN |
| UNDERGROUND ELECTRICAL | 10/21/2005 | APPROVED | JMCGOWEN |
| FOOTER | 10/11/2005 | APPROVED | JMCGOWEN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/01/2005 | 12/01/2005 |
| Note: Released By: LWOODROME Revision: Additional concrete support beam | |||
| BLD | COMPLETE | 09/29/2005 | 10/04/2005 |
| Note: Released By: LWOODROME | |||
| BLD | HOLD | 09/15/2005 | 09/22/2005 |
| Note: Held By: FREODICA CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2005080600 (Building No. 1) 1. Provide product approval number for exterior doors and garage doors. FYI: Complete product approval packets, for components and cladding, must be available, at the job site, at the time of inspection. 2. Provide details of guardrails, at balconies, that meet the requirements of FBC 1015. 3. Provide roofing application instructions per FBC 1507.4.1.2. 4. Provide a bottom plate, at landing support walls, in stair section details 1 & 2 (unit B) and section detail 1 (unit C). 5. Clarify roof sheathing thickness. (Drawing A3.1 references 5/8" while S-5 references ½") 6. Provide fire blocking, at ceiling level, for furred walls and between stair stringers, at the top and bottom of each run and in other concealed spaces as required by FBC sections 705.3 and 2305. 7. Provide signs or stencils, which read, "FIRE AND SMOKE BARRIER PROTECT ALL OPENINGS" on all walls of rated construction and draftstop partitions, above decorative ceilings, in attic spaces and in other concealed spaces, per FBC704.2.1.4. 8. Provide electrical disconnect(s) for condensing unit and water heater, unless within sight and 50' of originating panel. 9. Provide GFCI protection for receptacle outlet(s) at Family Room side of bar, typical for all units. 10. Provide switched lighting inside attic access. 11. Provide listed lighting fixtures in damp or wet locations. 12. Clarify water heater location(s), shown on sheet M-7 (detail) inside the AHU closet, shown on architectural and plumbing sheets in the garage and electrical sheets show connections in both locations. 13. Provide auxiliary pan with secondary drain or float switch, for AHU(s) installed above 1st finish floor elevation. 14. Provide (3) copies of revised energy calculations, which are specific to each typical unit. The following items were noted, revise accordingly: a. The packets submitted do not reference the correct "Climate Zone (North), "Permitting Office" (Palm Coast) and Jurisdiction Number (281400). b. All of the exterior walls were noted as frame walls when some are masonry. c. The units over the garage do not take into account the unconditioned space at the floor level. No insulation is shown on the architectural drawings. d. The first floor units that have second floor unit over them list an attic of R30, however some of the architectural plans only show R19 insulation here. e. The floor areas square footages listed do not match the floor plans. 15. Provide (1) set of mechanical plans, which is missing in the submitted package, except M7 (HVAC detail). 16. Locations of condensing units, HP-A, & HP-C shown on M5 & E5 are interchanged. | |||
| FD1 | COMPLETE | 08/17/2005 | 09/13/2005 |
| Note: Released By: JPATTEE |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 05/26/2006 |
| REVISION | ¤40.00 | 05/05/2006 |
| REINSPECTION FEE | ¤40.00 | 05/05/2006 |
| REINSPECTION FEE | ¤40.00 | 05/05/2006 |
| TTRANS IMPACT FEE CONDO/TOWN | ¤14,560.00 | 10/05/2005 |
| ADMIN FEE | ¤20.00 | 10/05/2005 |
| BUILDING CODE ADMIN FUND | ¤100.71 | 10/05/2005 |
| ELECTRIC FEE | ¤810.00 | 10/05/2005 |
| FIRE COMM IMPACT FEE 4-1-05 | ¤9,684.27 | 10/05/2005 |
| FIRE PLANS REVIEW | ¤201.42 | 10/05/2005 |
| MECHANICAL FEE | ¤810.00 | 10/05/2005 |
| PERMIT FEE | ¤7,150.00 | 10/05/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤11,209.10 | 10/05/2005 |
| PLUMBING FEE | ¤810.00 | 10/05/2005 |
| RADON FEE | ¤100.71 | 10/05/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤45,616.21 |