I want to search for...

Permit #2005080609

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-00960-0130
CONDITIONED SPACE: 2057 sqft
GARAGE: 610 sqft
OPENED PORCH (WITH ROOF) : 158 sqft
OPENED PORCH (WITH ROOF) : 50 sqft
Total Square Footage: 2875 sqft
Block: 0096
Subdivision: -
Job Phone: (386) 672-8285
Location Address: 9 LAKE PLACID PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/14/2005
NOC: RECORDED
Applicant name: JOSEPH TODD VANACORE
Owner: JAMES AND LORIE WILCOX

Address

10 BRIAN LANE

PALM COAST, FL 32137

Lot: 130
Contracted Stated Job Value: ¤180,000.00
Job Description: RESIDENTIAL SINGLE FAMILY HOME
Type: CN

Contractor

VANACORE CONSTRUCTION INC.
Status Location Address Mailing Address State License Number Phone
INACTIVE

1451 N US HIGHWAY 1

Ormond Beach, FL 32174

SUITE 13

Ormond Beach, FL 32174

CBC058991 (Exp: 08/31/2024) (386) 672-8285

Sub Contractors

DANIEL R SHEFFIELD
Status Location Address State License Number Phone
INACTIVE

1100 Old Haw Creek Road

Bunnell, FL 32110

EC0003100 (Exp: 08/31/2024) 386-931-4729

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 05/15/2006 CANCELLED BY INSPECTOR JLEVRAULT
FINAL COMPLETE BUILDING INSPECTION 05/12/2006 FINAL APPROVED JLEVRAULT
STORMWATER FINAL INSPECTION 05/10/2006 APPROVED - AS NOTED BFCHAMBERLAIN
Note: THIS IS A REINSPECTION 28 s.f. road damages $324
UTILITY COMPANY FINAL 05/09/2006 APPROVED RANDRADE
STORMWATER FINAL INSPECTION 05/08/2006 Disapproved -FEE REQUIRED BFCHAMBERLAIN
Note: Place sod on exposed earth on right adj property D.M. needed from #9 to ditch, and Vactron needed for #11,s culvert
RESIDENTIAL EARLY POWER 04/17/2006 APPROVED MMOORE
PRE DRIVEWAY 03/29/2006 APPROVED BFCHAMBERLAIN
LATH /BRICK FLASHING 02/14/2006 APPROVED MMOORE
INSULATION INSPECTION 02/03/2006 APPROVED MMOORE
ALL ROUGH 01/31/2006 APPROVED MMOORE
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 01/18/2006 APPROVED - AS NOTED MMOORE
Note: 1. htt-22/ bottom at study finish nailing 2. 2-ply m. bath, m.b. room nail tight together 3. inspection #354 passes 4. complete above items by all-rough insp.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 01/13/2006 CANCELLED BY INSPECTOR MMOORE
Note: PACK-OUT JACK CJ03 ON RIGHT 2. GROUT UNDER TRUSSES WITH STONELESS GROUT 3. CANCELLED BY INSPECTOR/ NO CHARGE/ CALL-IN NEXT WEEK FOR RE-INSPECTION/ WE ARE CLOSED ON MONDAY/ MARTIN LUTHER KING DAY
LINTEL 12/01/2005 APPROVED MMOORE
MONOLITHIC SLAB INSPECTION/SLAB 11/17/2005 APPROVED MMOORE
FIRST ROUGH PLUMBING INSPECTION 11/16/2005 APPROVED JLEVRAULT
Note: THIS IS A REINSPECTION
FIRST ROUGH PLUMBING INSPECTION 11/15/2005 Disapproved -FEE REQUIRED JLEVRAULT
Note: THIS IS A REINSPECTION NO HEAD PREASSURE ON DWV.
FIRST ROUGH PLUMBING INSPECTION 11/14/2005 Disapproved -FEE REQUIRED JLEVRAULT
Note: No pressure on DWV.

Review History

Department Status Date In Date Out
BLD COMPLETE 12/22/2005 12/22/2005
Note: Released By: LWOODROME Revision: Window and door buck attachment
BLD COMPLETE 09/09/2005 09/09/2005
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 08/23/2005 08/25/2005
Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. Sheet 7 appears to be missing. Please provide if there is indeed a sheet 7. 2. Provide a truss layout and connector schedule. 3. Provide a bond beam transition detail. 4. The floor plan references details A/5 & B/5 however these details could not be found on sheet 5. Please provide these details. 5. Clarify lintels to be used. The schedule lists 8x8 and the diagram below shows a 16" deep lintel that is filled and reinforced. The description, diagram and wall sections shall all match.
SWMD COMPLETE 08/17/2005 08/18/2005
Note: Released By: LAPTEKAR
ZON COMPLETE 08/17/2005 08/23/2005
Note: Released By: HHERKERT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤324.00 05/15/2006
EARLY POWER INSPECTION ¤40.00 05/15/2006
REINSPECTION FEE ¤40.00 05/15/2006
REINSPECTION FEE ¤40.00 05/15/2006
REVISION ¤40.00 05/15/2006
STORMWATER REINSPECTION FEE ¤35.00 05/15/2006
TRANSPORTATION IMPACT FEE3/RES ¤2,885.00 09/14/2005
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 09/14/2005
STORM WATER PERMIT FEES ¤80.00 09/14/2005
ADMIN FEE ¤20.00 09/14/2005
ARC HOUSE REVIEW ¤125.00 09/14/2005
BUILDING CODE ADMIN FUND ¤14.38 09/14/2005
ELECTRIC FEE ¤138.00 09/14/2005
FIRE RES IMPACT FEE 4-1-05 ¤173.47 09/14/2005
MECHANICAL FEE ¤138.00 09/14/2005
PERMIT FEE ¤702.00 09/14/2005
PARKS IMPACT FEE 11-2-04 ¤1,120.91 09/14/2005
PLAN CHECK FEE ¤72.00 09/14/2005
PLUMBING FEE ¤138.00 09/14/2005
RADON FEE ¤14.38 09/14/2005
Fees Total Due: ¤0.00 Total Paid: ¤9,740.14