I want to search for...

Permit #2005080755

Permit Details

Status: COED

CONDITIONED SPACE: 18579 sqft
OPENED PORCH (WITH ROOF) : 4161 sqft
Total Square Footage: 22740 sqft
Subdivision: 2085 - Tidelands at the Village Phase II
Job Phone: (407)838-1486
Location Address: 65 RIVERVIEW BEND S
Type: BCR - BUILDING COMMERCIAL RESIDENTIAL -CONDO
Issue Date: 10/27/2005
NOC: RECORDED
Applicant name: JAMES NICHOLSON BOYCE IV
Owner: CENTEX DESTINATION PROPERTIES
Contracted Stated Job Value: ¤1,672,110.00
Job Description: BUILDING # 17 - 12 PLEX TOWNHOUSE
Type: CN

Contractor

CENTEX DESTINATION PROPERTIES
Status Location Address Mailing Address State License Number Phone
CANCEL

1064 GREENWOOD BLVD

LAKE MARY, FL 32746

STE. 200

LAKE MARY, FL 32746

CGC1508651 (Exp: 08/31/2010) (407)838-1486

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 09/12/2006 FINAL APPROVED JLEVRAULT
UTILITY COMMERCIAL FINAL 09/11/2006 APPROVED KKING
UTILITY COMPANY FINAL 09/11/2006 APPROVED TSCHWEERS
FIRE FINAL 08/15/2006 APPROVED JPATTEE
LANDSCAPE FINAL 08/10/2006 APPROVED WBUTLER
ENGINEERING FINAL 08/10/2006 APPROVED DMAY
FLOOD ZONE 'A' ELEVATION CERTIFICATE APPROVAL 07/21/2006 APPROVED - AS NOTED CBENTLEY
Note: It appears that this structure is outside the flood zone A and is in C. Need surveyor to correct original elevation certificate.
COMMERCIAL POWER INSPECTION 07/18/2006 APPROVED RMARVEL
INSULATION INSPECTION 05/25/2006 APPROVED JMCGOWEN
Note: THIS IS A REINSPECTION
ALL ROUGH 05/24/2006 CANCELLED BY APPLICANT JMCGOWEN
ALL ROUGH 05/19/2006 APPROVED JMCGOWEN
Note: THIS IS A REINSPECTION 3rd floor aproved
ALL ROUGH 05/17/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: 3rd floor spacing of rec. mark white wires used as hot conductors.
INSULATION INSPECTION 05/12/2006 Disapproved - NO FEE JMCGOWEN
Note: first and second floor insulation passed
FRAMING 05/03/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: 1. strapping, nail plates 2. add rec. in hall and bedroom by door 3. ko plug missing 4. mc on porch
FIREWALL INSPECTION 3ND ROUGH 05/03/2006 APPROVED JPATTEE
FIREWALL INSPECTION 04/26/2006 APPROVED JPATTEE
SECOND ROUGH PLUMBING INSPECTION 04/19/2006 APPROVED JMCGOWEN
Note: second floor all rough too
ALL ROUGH 03/30/2006 APPROVED - AS NOTED JMCGOWEN
Note: check fire stop
LINTEL 12/20/2005 APPROVED TOUTLAND
MONOLITHIC SLAB INSPECTION/SLAB 12/07/2005 APPROVED TOUTLAND
FIRST ROUGH PLUMBING INSPECTION 12/05/2005 APPROVED TOUTLAND
UNDERGROUND ELECTRICAL 12/05/2005 APPROVED TOUTLAND
STEM FOOTING FOUNDATION 11/16/2005 APPROVED JMCGOWEN

Review History

Department Status Date In Date Out
BLD COMPLETE 08/23/2006 09/11/2006
Note: Released By: BBEMBRY approved per Carl Cote
BLD COMPLETE 11/29/2005 11/29/2005
Note: Released By: LWOODROME Revision: Drywell and condesate piping
BLD COMPLETE 10/27/2005 10/27/2005
Note: Released By: CCOTE Approved for Release.
BLD HOLD 09/22/2005 10/14/2005
Note: Held By: FREODICA CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2005080755 (Building No. 17) 1. Provide product approval number for exterior doors and garage doors. FYI: Complete product approval packets, for components and cladding, must be available, at the job site, at the time of inspection. 2. Provide details of guardrails, at balconies, that meet the requirements of FBC 1015. 3. Provide more information on details of balcony screen enclosure showing sizes, spacing and method of attachment. 4. Provide roofing application instructions per FBC 1507.4.1.2. 5. Clarify roof sheathing thickness. (Drawing A3.1C references 5/8" while S-6 references ½") 6. Provide signs or stencils, which read, "FIRE AND SMOKE BARRIER PROTECT ALL OPENINGS" on all walls of rated construction and draftstop partitions, above decorative ceilings, in attic spaces and in other concealed spaces, per FBC704.2.1.4. 7. Provide electrical disconnect(s) for condensing unit and water heater, unless within sight and 50' of originating panel. 8. Provide GFCI protection for receptacle outlet(s) at Great Room side of bar, typical for all units. 9. Provide listed lighting fixtures in damp or wet locations. 10. Provide (3) copies of revised energy calculations, which are specific to each typical unit. a. The following items were noted, revise accordingly. The packets submitted do not reference the correct "Permitting Office" (Palm Coast) and Jurisdiction Number (281400). 11. Clarify dryer vent equivalent length, 50 ft or 60 ft? Please add note to provide signs or stencils, which read, "Dryer shall be capable of venting through 60 equivalent ft." on wall close to dryer. 12. On sanitary riser diagrams, show how vent system is connected from 1st floor to 3rd floor to outside the building. 13. A1.1S, A1.2S, A1.3S, A5.2 & A7.3: a. Stair tread and riser height shall meet code. 14. A1.2A & A1.2B: a. Delete all notes not applicable (4rth floor plan title, room notes etc.) 15. A4.2: a. Show location of AC-1 on second floor elevator room.(see comment 18b) 16. A7.5.1: a. Detail 7- Tenant Separation @ Top Floor on A i. Clarify referenced detail 2/A7.5 ii. Clarify referenced sheet A7.7 17. M1 to M2: a. Coordinate all Plan key notes references to match referenced details/sheets. b. Indicate exhaust fan/dryer ducts routing reference dwg. continuation. 18. M3: a. Same as 16a. b. Coordinate with Architectural/structural the location of AC-1 opening for elevator room. How is condensate drain routed outside the building.(see plan note 6). c. Revise HP units quantity to match with electrical-(E3). 19. P5: a. Sanitary risers S/5 & S/6 are interchanged. b. Sanitary riser S/5 does not match with layout. c. Domestic water riser- Unit A title is missing 20. P6: a. Coordinate references on risers W/1 & TP/1 with plan notes. 21. Cover sheet: a. Revise Index of Drawings to match drawing sheets. i. AS-1 Architectural site plan is missing in the package.
FI1 COMPLETE 08/22/2005 09/21/2005
Note: Released By: JPATTEE

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 09/13/2006
REINSPECTION FEE ¤40.00 09/13/2006
REVISION ¤40.00 09/13/2006
REVISION ¤40.00 09/13/2006
TTRANS IMPACT FEE CONDO/TOWN ¤17,472.00 10/27/2005
ADMIN FEE ¤20.00 10/27/2005
BUILDING CODE ADMIN FUND ¤113.70 10/27/2005
ELECTRIC FEE ¤1,033.80 10/27/2005
FIRE COMM IMPACT FEE 4-1-05 ¤10,933.39 10/27/2005
FIRE PLANS REVIEW ¤227.40 10/27/2005
MECHANICAL FEE ¤1,033.80 10/27/2005
PERMIT FEE ¤9,201.50 10/27/2005
PARKS IMPACT FEE 11-2-04 ¤13,450.92 10/27/2005
PLUMBING FEE ¤1,033.80 10/27/2005
RADON FEE ¤113.70 10/27/2005
Fees Total Due: ¤0.00 Total Paid: ¤54,794.01