I want to search for...
Permit #2005080836
Permit Details
Status: COED
| Parcel Id: 07-11-31-7016-00060-0720 |
| CONDITIONED SPACE: 2405 sqft |
| OPENED PORCH (WITH ROOF) : 380 sqft |
| OPENED PORCH (WITH ROOF) : 90 sqft |
| GARAGE: 625 sqft |
| Total Square Footage: 3500 sqft |
| Block: 0006 |
| Subdivision: - |
| Job Phone: (386) 445-2222 |
| Location Address: 107 COLECHESTER LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/11/2005 |
| NOC: RECORDED |
| Applicant name: MICHAEL STEPHAN MULLEN |
| Owner: CHARLES E DOUBLEDAY AND ELEANOR BURLINGHAM |
|
Address 167 WEST END AVE # 10 A NEW YORK, NY 10024 |
| Lot: 720 |
| Contracted Stated Job Value: ¤120,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
TOWN & COUNTRY HOMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1 Enterprise Drive Bunnell, FL 32110 |
CGC049972 (Exp: 08/31/2026) | (386) 445-2222 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 11/02/2006 | FINAL APPROVED | JMCGOWEN |
| FINAL COMPLETE BUILDING INSPECTION | 11/01/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: need energy sheets and full set of plans and permit. need rec. in kitchen cabinet. PVC where subject to physical damage needs to be sch. 80.(pool equipment). ground timer at pool timer. | |||
| UTILITY COMPANY FINAL | 10/25/2006 | APPROVED | TSCHWEERS |
| Note: THIS IS A REINSPECTION | |||
| STORMWATER FINAL INSPECTION | 10/24/2006 | APPROVED - AS NOTED | DRANDALL |
| Note: THIS IS A REINSPECTION remove all dirt runoff from canal before CO can be issued. 34 sf road damage | |||
| UTILITY COMPANY FINAL | 10/20/2006 | Disapproved - NO FEE | JSHEVLIN |
| Note: FAILED TRASH AND DIRT IN 4" SEWER CLEAN ALSO NO CAP | |||
| STORMWATER FINAL INSPECTION | 10/20/2006 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: 34 sf road damage..$ 372.00.....clean up trash across street swale & adj. property.....also, right side adj. property.....finish landscape package.....reinstall silt fence right rear to control runoff | |||
| RESIDENTIAL EARLY POWER | 10/20/2006 | APPROVED | ACOOPER |
| PRE DRIVEWAY | 10/09/2006 | APPROVED | DRANDALL |
| INSULATION INSPECTION | 08/15/2006 | APPROVED | KSAMPICO |
| INSULATION INSPECTION | 08/14/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: MISSING FIRESTOP IN MANY AREAS.CODE SECTION 717 F.B.C. | |||
| LATH /BRICK FLASHING | 08/10/2006 | APPROVED | PGALLMANN |
| ALL ROUGH | 08/08/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 07/27/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: need bond jumper between ground terminal bars in panel, fire stop missing , need aproved revisions for repairs for trusses H-01,H-O2,H-03 and H-04, seal off A/C chase in garage | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 06/12/2006 | APPROVED - AS NOTED | JMCGOWEN |
| Note: 2 down cells need filled. 1 in garage. 1 at left of house. | |||
| LINTEL | 05/03/2006 | APPROVED | JGIBSON |
| MONOLITHIC SLAB INSPECTION/SLAB | 04/19/2006 | APPROVED | JGIBSON |
| RETAINING WALL | 03/23/2006 | APPROVED | ARAYMOND |
| RETAINING WALL | 03/14/2006 | APPROVED | ARITTER |
| FIRST ROUGH PLUMBING INSPECTION | 03/10/2006 | APPROVED | ARAYMOND |
| TEMPORARY POLE | 02/17/2006 | APPROVED | ARAYMOND |
| Note: fpl called on 2/17/06 at 4:00pm Damaris |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 08/02/2006 | 08/03/2006 |
| Note: Released By: LWOODROME Revision: Truss repair | |||
| BLD | COMPLETE | 10/10/2005 | 10/10/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R> | |||
| BLD | HOLD | 09/30/2005 | 10/04/2005 |
| Note: Held By: FREODICA 1. Gable end detail-OK 2.Truss layout - OK 3. Submit revised truss connector to match newly submitted revised truss layout. | |||
| BLD | HOLD | 08/31/2005 | 09/01/2005 |
| Note: Held By: FREODICA 1. Provide gable end wall detail at rear gable (family room with cathedral ceiling) to comply with FBC 2001/Building section 2117.1. 2. Truss layout does not match with floor plan. | |||
| SWMD | COMPLETE | 08/23/2005 | 08/30/2005 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 08/23/2005 | 08/31/2005 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤372.00 | 11/28/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 11/28/2006 |
| REINSPECTION FEE | ¤40.00 | 11/28/2006 |
| REINSPECTION FEE | ¤40.00 | 11/28/2006 |
| REINSPECTION FEE | ¤40.00 | 11/28/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 11/28/2006 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 10/11/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 10/11/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 10/11/2005 |
| ADMIN FEE | ¤20.00 | 10/11/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 10/11/2005 |
| BUILDING CODE ADMIN FUND | ¤17.50 | 10/11/2005 |
| ELECTRIC FEE | ¤147.00 | 10/11/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 10/11/2005 |
| MECHANICAL FEE | ¤147.00 | 10/11/2005 |
| PERMIT FEE | ¤760.50 | 10/11/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 10/11/2005 |
| PLAN CHECK FEE | ¤78.00 | 10/11/2005 |
| PLUMBING FEE | ¤147.00 | 10/11/2005 |
| RADON FEE | ¤17.50 | 10/11/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,885.88 |