Permit #2005080974

Permit Details

Status: COED

CONDITIONED SPACE: 29852 sqft
OPENED PORCH (WITH ROOF) : 6624 sqft
Total Square Footage: 36476 sqft
Subdivision: 2085 - Tidelands at the Village Phase II
Job Phone: (407)838-1486
Location Address: 75 RIVERVIEW BEND S
Type: BCR - BUILDING COMMERCIAL RESIDENTIAL -CONDO
Issue Date: 12/08/2005
NOC: RECORDED
Applicant name: JAMES NICHOLSON BOYCE IV
Owner: CENTEX DESTINATION PROPERTIES
Contracted Stated Job Value: ¤2,686,680.00
Job Description: BUILDING #16 20 PLEX CONDOMINIUM UNIT
Type: CN

Contractor

CENTEX DESTINATION PROPERTIES
Status Location Address Mailing Address State License Number Phone
CANCEL

1064 GREENWOOD BLVD

LAKE MARY, FL 32746

STE. 200

LAKE MARY, FL 32746

CGC1508651 (Exp: 08/31/2010) (407)838-1486

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 11/07/2006 FINAL APPROVED JLEVRAULT
Note: electrical final approved. RM
UTILITY COMMERCIAL FINAL 11/03/2006 APPROVED KKING
UTILITY COMPANY FINAL 11/03/2006 APPROVED TSCHWEERS
ENGINEERING FINAL 11/01/2006 APPROVED MCOBB
LANDSCAPE FINAL 10/27/2006 APPROVED WBUTLER
FIRE FINAL 10/20/2006 APPROVED JPATTEE
MONOLITHIC SLAB INSPECTION/SLAB 09/22/2006 Disapproved - NO FEE JLEVRAULT
Note: NEED LETTER OF MISSED INSPECTION.
FOOTER 09/22/2006 Disapproved - NO FEE JLEVRAULT
Note: NEED LETTER OF MISSED INSPECTION.
LINTEL 09/22/2006 Disapproved - NO FEE JLEVRAULT
Note: NEED LETTER OF MISSED INSPECTION.
FRAMING 09/22/2006 APPROVED JLEVRAULT
Note: FRAMING PASSED 6/27/06 AND 7/26/06 PER HISTORY SHEET.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/22/2006 Disapproved - NO FEE JLEVRAULT
Note: NEED LETTER OF MISSED INSPECTION.
COMMERCIAL POWER INSPECTION 09/15/2006 APPROVED - AS NOTED RMARVEL
Note: fourth floor early power. released to fpl
COMMERCIAL POWER INSPECTION 09/08/2006 APPROVED RMARVEL
COMMERCIAL POWER INSPECTION 09/01/2006 APPROVED RMARVEL
INSULATION INSPECTION 08/03/2006 APPROVED JLEVRAULT
Note: pREVIOUSLY APPROVED ON 7/20/06.
COMMERCIAL POWER INSPECTION 08/02/2006 APPROVED RMARVEL
FIREWALL INSPECTION 07/31/2006 APPROVED JPATTEE
FIREWALL INSPECTION 07/27/2006 APPROVED JPATTEE
ALL ROUGH 07/26/2006 APPROVED - AS NOTED JGIBSON
Note: Third & forth floor plumbing tested OK. THIRD AND FOURTH FLOORS PASSED FRAMING AND MECHANICAL INSPECTION (JL).
SECOND ROUGH PLUMBING INSPECTION 07/25/2006 APPROVED - AS NOTED JGIBSON
Note: Third & forth floor plumbing OK.
SECOND ROUGH PLUMBING INSPECTION 07/24/2006 CANCELLED BY APPLICANT JLEVRAULT
INSULATION INSPECTION 07/20/2006 APPROVED JLEVRAULT
Note: INSULATION NOW COMPLETE ON THIS BUILDING.
INSULATION INSPECTION 07/17/2006 APPROVED - AS NOTED JLEVRAULT
Note: THIS IS A REINSPECTION FIRST FLOOR ONLY - SECOND FLOOR STILL NOT READY.
INSULATION INSPECTION 07/13/2006 Disapproved -FEE REQUIRED JLEVRAULT
Note: NOT READT - INSULATION MISSING - RIDGID INSULATION MISSING - REMOVE PAPER FROM TOP OF BATH VENT CANS.
FIREWALL INSPECTION 07/13/2006 APPROVED - AS NOTED JPATTEE
Note: 1st and 2nd floor penetrations
ALL ROUGH 06/27/2006 Disapproved - NO FEE RMARVEL
Note: 1st and 2nd floor are ok. FRAMING AND MECHANICAL ARE PASSED AS NOTED ON FIRST AND SECOND FLOOR. ALL WINDOWS AND DOORS MUST BE TAPCONNED ACCORDING TO PLAN DETAILS. INSTALL PROTECTIVE WIRE PLATED WHERE REQUIRED.**************CHECK AT INSULATION**************
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 06/20/2006 APPROVED PPROVIDER
Note: THIS IS A REINSPECTION Threshold inspectors report
SECOND ROUGH PLUMBING INSPECTION 04/19/2006 APPROVED JMCGOWEN
Note: first and second floor
SECOND FLOOR SLAB INSPECTION 02/15/2006 APPROVED PPROVIDER
Note: Threshold inspectors report
LINTEL 02/15/2006 APPROVED PPROVIDER
Note: THIS IS A REINSPECTION Threshold inspectors report
POURED CELL 02/06/2006 APPROVED PPROVIDER
MONOLITHIC SLAB INSPECTION/SLAB 01/23/2006 APPROVED PPROVIDER
Note: THIS IS A REINSPECTION Threshold inspectors report
FIRST ROUGH PLUMBING INSPECTION 01/18/2006 APPROVED TOUTLAND
UNDERGROUND ELECTRICAL 01/18/2006 APPROVED TOUTLAND
FOOTER 12/17/2005 APPROVED PPROVIDER
Note: THIS IS A REINSPECTION Threshold inspectors report
STEM FOOTING FOUNDATION 12/16/2005 CANCELLED BY INSPECTOR TOUTLAND

Review History

Department Status Date In Date Out
BLD COMPLETE 12/02/2005 12/05/2005
Note: Released By: LWOODROME
BLD HOLD 11/28/2005 11/28/2005
Note: Held By: FREODICA Refering to your response to plan review comments: 1. Comment #12, SGM's response was ok except for sanitary risers S/2 & S/4 on sheet P6. On S/2, the bathroom vents(except on 4th floor) shall not be connected to the 4" main soil or waste stack. Also, please recalculate the size of the vent stack through the roof per FBC 2001/P table 916.1. Similary, on sanitary riser S/4, the stack vent shall be sized per FBC 2001/P table 916.1. 2. Comment #17c, condesate disposal shall be revised to comply with FBC 2001/P as previously discussed.
BLD HOLD 09/23/2005 10/15/2005
Note: Held By: FREODICA CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2005080974 (Building No. 16) 1. Provide product approval number for exterior doors and garage doors. FYI: Complete product approval packets, for components and cladding, must be available, at the job site, at the time of inspection. 2. Provide details of guardrails, at balconies, that meet the requirements of FBC 1015. 3. Provide more information on details of balcony screen enclosure showing sizes, spacing and method of attachment. 4. Provide roofing application instructions per FBC 1507.4.1.2. 5. Clarify roof sheathing thickness. (Drawing A3.1C references 5/8" while S-6 references ½") 6. Provide signs or stencils, which read, "FIRE AND SMOKE BARRIER PROTECT ALL OPENINGS" on all walls of rated construction and draftstop partitions, above decorative ceilings, in attic spaces and in other concealed spaces, per FBC704.2.1.4. 7. Provide electrical disconnect(s) for condensing unit and water heater, unless within sight and 50' of originating panel. 8. Provide GFCI protection for receptacle outlet(s) at Great Room side of bar, typical for all units. 9. Provide listed lighting fixtures in damp or wet locations. 10. Provide (3) copies of revised energy calculations, which are specific to each typical unit. a. The following items were noted, revise accordingly. The packets submitted do not reference the correct "Permitting Office" (Palm Coast) and Jurisdiction Number (281400). 11. Clarify dryer vent equivalent length, 50 ft or 60 ft? Please add note to provide signs or stencils, which read, "Dryer shall be capable of venting through 60 equivalent ft." on wall close to dryer. 12. On sanitary riser diagrams, show how vent system is connected from 1st floor to 4th floor to outside the building. 13. A1.1S, A1.2S, A1.3S, A5.2 & A7.3: a. Stair tread and riser height shall meet code. 14. A5.3, A4.1: a. Show location of AC-1 on second floor elevator room.(see comment 18b) 15. A7.5.1: a. Detail 7- Tenant Separation @ Top Floor on A i. Clarify referenced detail 2/A7.5 ii. Clarify referenced sheet A7.7 16. M1 to M2: a. Plan key note #2 (refrigerant/condensate piping) continuation reference sheet not shown. b. Indicate fan/dryer exhaust ducts routing reference dwg. continuation. 17. M3: a. Condensing units(heat pumps) are shown 15 only instead of 20 units. b. Coordinate with Architectural/structural the location of AC-1 opening for elevator room. How is condensate drain routed outside the building.(see plan note 6). c. Condensate from all AHU's shall be disposed to an approved place of disposal per FBC/M 2001 section 307. This applies to all previously submitted comments that I missed. 18. E3: a. Condensing units(heat pumps) are not clearly identified. (see comment 17a). 19. P5: a. Domestic water riser for unit C does not match with layout. 20. P6: a. Coordinate references on risers W/1 & TP/1 with plan notes. 21. Cover sheet: a. Revise Index of Drawings to match drawing sheets title. i. AS-1 Architectural site plan is missing in the package. ii. Clarify A5.3 (not listed but in package) & A5.4 (listed but not in package).
FI1 COMPLETE 08/29/2005 09/23/2005
Note: Released By: JPATTEE

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 10/24/2006
TTRANS IMPACT FEE CONDO/TOWN ¤29,120.00 12/08/2005
ADMIN FEE ¤20.00 12/08/2005
BUILDING CODE ADMIN FUND ¤182.38 12/08/2005
ELECTRIC FEE ¤1,642.01 12/08/2005
FIRE COMM IMPACT FEE 4-1-05 ¤17,537.66 12/08/2005
FIRE PLANS REVIEW ¤364.76 12/08/2005
MECHANICAL FEE ¤1,642.01 12/08/2005
PERMIT FEE ¤14,776.74 12/08/2005
PARKS IMPACT FEE 11-2-04 ¤22,418.20 12/08/2005
PLUMBING FEE ¤1,642.01 12/08/2005
RADON FEE ¤182.38 12/08/2005
Fees Total Due: ¤0.00 Total Paid: ¤89,568.15