I want to search for...

Permit #2005080975

Permit Details

Status: COED

CONDITIONED SPACE: 44744 sqft
OPENED PORCH (WITH ROOF) : 13088 sqft
Total Square Footage: 57832 sqft
Subdivision: 2085 - Tidelands at the Village Phase II
Job Phone: (407)838-1486
Location Address: 45 RIVERVIEW BEND S
Type: BCR - BUILDING COMMERCIAL RESIDENTIAL -CONDO
Issue Date: 12/28/2005
NOC: RECORDED
Applicant name: JAMES NICHOLSON BOYCE IV
Owner: CENTEX DESTINATION PROPERTIES
Contracted Stated Job Value: ¤3,600,000.00
Job Description: BUILDING #19 28 PLEX CONDOMINIUM UNIT
Type: CN

Contractor

CENTEX DESTINATION PROPERTIES
Status Location Address Mailing Address State License Number Phone
CANCEL

1064 GREENWOOD BLVD

LAKE MARY, FL 32746

STE. 200

LAKE MARY, FL 32746

CGC1508651 (Exp: 08/31/2010) (407)838-1486

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 01/08/2007 FINAL APPROVED JLEVRAULT
ENGINEERING FINAL 01/03/2007 APPROVED DMAY
UTILITY COMMERCIAL FINAL 01/02/2007 APPROVED DSPENCER
UTILITY COMPANY FINAL 01/02/2007 APPROVED TSCHWEERS
LANDSCAPE FINAL 01/02/2007 APPROVED WBUTLER
PLUMBING FINAL 12/20/2006 APPROVED PGALLMANN
H.V.A.C. FINAL 12/19/2006 APPROVED JLEVRAULT
ELECTRICAL FINAL 12/18/2006 APPROVED RMARVEL
Note: CALLED FPL ON 12/18/06 MD
FIRE FINAL 12/15/2006 APPROVED JPATTEE
COMMERCIAL POWER INSPECTION 11/29/2006 APPROVED LHITES
Note: THIS IS A REINSPECTION 4TH FLOOR EARLY POWER IS OK/CALLED FPL ON 11/29/06
COMMERCIAL POWER INSPECTION 11/22/2006 CANCELLED BY APPLICANT LHITES
THRESHOLD/AFFIDAVIT 11/14/2006 APPROVED PPROVIDER
Note: Threshhold Report from Law & Associates
COMMERCIAL POWER INSPECTION 11/01/2006 APPROVED RMARVEL
Note: 3rd floor early power.
COMMERCIAL POWER INSPECTION 10/24/2006 APPROVED LHITES
Note: COMMERCIAL EARLY POWER FOR FLOORS 1 AND 2 IS OK
INSULATION INSPECTION 10/24/2006 APPROVED - AS NOTED JLEVRAULT
Note: FOURTH FLOOR INSULATION APPROVED.
INSULATION INSPECTION 10/23/2006 Disapproved -FEE REQUIRED JHINDMAN
Note: FIRESTOP ALL CHASES AND DROP CEILINGS
ALL ROUGH 10/17/2006 APPROVED RMARVEL
Note: 4th floor. MECHANICAL AND FRAMING APPROVED FOR FOURTH FLOOR BY JOE LEVRAULT.
ALL ROUGH 10/04/2006 APPROVED - AS NOTED RMARVEL
Note: THIS IS A REINSPECTION fourth floor electric rough approved.
INSULATION INSPECTION 09/29/2006 APPROVED - AS NOTED JLEVRAULT
Note: THIRD FLOOR APPROVED.
COMMERCIAL POWER INSPECTION 09/28/2006 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
COMMERCIAL POWER INSPECTION 09/26/2006 CANCELLED BY APPLICANT RMARVEL
Note: courtney cancelled.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/26/2006 Disapproved - NO FEE JLEVRAULT
Note: NEED LETTER OF MISSED INSPECTION.
MONOLITHIC SLAB INSPECTION/SLAB 09/26/2006 Disapproved - NO FEE JLEVRAULT
Note: NEED LETTER OF MISSED INSPECTION.
FOOTER 09/26/2006 Disapproved - NO FEE JLEVRAULT
Note: NEED LETTER OF MISSED INSPECTION.
LINTEL 09/26/2006 Disapproved - NO FEE JLEVRAULT
Note: NEED LETTER OF MISSED INSPECTION.
FIREWALL INSPECTION 09/21/2006 APPROVED JPATTEE
SECOND ROUGH PLUMBING INSPECTION 09/19/2006 APPROVED PGALLMANN
Note: APPROVED THROUGH ROOF.
ALL ROUGH 09/15/2006 Disapproved -FEE REQUIRED JGIBSON
Note: THIRD FLOOR FRAMING AND MECHANICAL PASSED. Third floor plumbing failed no test on sanitary, riser clamps not installed per manufactures specs, remove ALL DRY-WALL & INSULATION FROM SECOND FLOOR CEILING FOR INSPECTION ON THIRD FLOOR SANITARY TEST.
INSULATION INSPECTION 09/06/2006 APPROVED - AS NOTED JHINDMAN
Note: THIS IS A REINSPECTION 1st @ 2nd floors
INSULATION INSPECTION 08/31/2006 CANCELLED BY APPLICANT JLEVRAULT
Note: CONTRACTOR CANCELLED THE INSPECTION - NOT READY.
FIREWALL INSPECTION 08/23/2006 APPROVED - AS NOTED JPATTEE
Note: 1st 2nd floor penetrations
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/14/2006 APPROVED PPROVIDER
Note: THIS IS A REINSPECTION Threshold inspectors report
ALL ROUGH 08/11/2006 CANCELLED BY APPLICANT AIRS WEB
2ND ROUGH ELECTRICAL 08/01/2006 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
SECOND FLOOR SLAB INSPECTION 07/31/2006 APPROVED PPROVIDER
Note: Elevator cap slab Threshold inspectors report
2ND ROUGH ELECTRICAL 07/28/2006 Disapproved -FEE REQUIRED RMARVEL
Note: strap EMT where longer than 10ft. recheck spacing of receptacles in kitchen. all unused openings need to be closed. EMT in panels need bushings. nail plates needed in numerous locations.
ALL ROUGH 07/26/2006 APPROVED - AS NOTED JGIBSON
Note: First & second floor plumbing is tested OK. FIRST AND SECOND FRAMING AND MECHANICAL PASSED INSPECTION.(JL)
LINTEL 07/26/2006 APPROVED PPROVIDER
Note: parapit walls, elevator shaft and roof top columns Threshold inspectors report
FLOOD ZONE 'A' ELEVATION CERTIFICATE APPROVAL 07/25/2006 APPROVED CBENTLEY
SECOND FLOOR SLAB INSPECTION 07/14/2006 APPROVED PPROVIDER
Note: roof slab Threshold inspectors report
LINTEL 07/06/2006 APPROVED PPROVIDER
Note: 4th floor lintels Threshold inspectors report
SECOND FLOOR SLAB INSPECTION 06/22/2006 APPROVED PPROVIDER
Note: 4th floor slab Threshold inspectors report
POURED CELL 06/02/2006 APPROVED PPROVIDER
Note: 3rd floor filled cels Threshold inspectors report
SECOND FLOOR SLAB INSPECTION 05/19/2006 APPROVED PPROVIDER
Note: 3rd floor slab. Threshold inspectors report
POURED CELL 05/08/2006 APPROVED PPROVIDER
Note: 2nd floor filled cells. Threshold inspectors report
SECOND FLOOR SLAB INSPECTION 04/12/2006 APPROVED PPROVIDER
Note: Threshold inspectors report
LINTEL 04/03/2006 APPROVED PPROVIDER
Note: THIS IS A REINSPECTION Threshold inspectors reeport
MONOLITHIC SLAB INSPECTION/SLAB 03/16/2006 APPROVED PPROVIDER
Note: THIS IS A REINSPECTION Threshold inspectors report.
FIRST ROUGH PLUMBING INSPECTION 03/14/2006 APPROVED TOUTLAND
UNDERGROUND ELECTRICAL 03/14/2006 APPROVED TOUTLAND
STEM FOOTING FOUNDATION 03/07/2006 APPROVED PPROVIDER
Note: Threshold inspectors report
STEM FOOTING FOUNDATION 03/02/2006 APPROVED PPROVIDER
Note: Threshold inspectors report
RETAINING WALL FOUNDATION INSPECTION 02/20/2006 APPROVED PPROVIDER
Note: Threshold inspectors report.
FOOTER 01/27/2006 APPROVED PPROVIDER
Note: THIS IS A REINSPECTION Threshold inspectors report.

Review History

Department Status Date In Date Out
BLD COMPLETE 08/02/2006 08/03/2006
Note: Released By: CCOTE Approved for Release. Review by Fred R. Revision: Roof Access tower.
BLD COMPLETE 11/29/2005 11/30/2005
Note: Released By: LWOODROME
BLD HOLD 11/28/2005 11/28/2005
Note: Held By: FREODICA 1. Drawing sheets A7.9.1 & A7.9.2 (mechanical roof plan) are missing in the submitted plan review comments response package.
BLD HOLD 09/21/2005 10/13/2005
Note: Held By: FREODICA CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2005080975 (Building No. 19) 1. Provide product approval number for exterior doors and garage doors. FYI: Complete product approval packets, for components and cladding, must be available, at the job site, at the time of inspection. 2. Provide details of guardrails, at balconies, that meet the requirements of FBC 1015. 3. Provide more information on details of balcony screen enclosure showing sizes, spacing and method of attachment. 4. Provide roofing application instructions per FBC 1507.4.1.2. 5. Clarify roof sheathing thickness. (Drawing A3.1C references 5/8" while S-6 references ½") 6. Provide signs or stencils, which read, "FIRE AND SMOKE BARRIER PROTECT ALL OPENINGS" on all walls of rated construction and draftstop partitions, above decorative ceilings, in attic spaces and in other concealed spaces, per FBC704.2.1.4. 7. Provide electrical disconnect(s) for condensing unit and water heater, unless within sight and 50' of originating panel. See Unit D on E4. 8. Provide GFCI protection for receptacle outlet(s) at Dining Room side of bar, typical for all units. 9. Provide listed lighting fixtures in damp or wet locations. 10. Provide (3) copies of revised energy calculations, which are specific to each typical unit. a. The following items were noted, revise accordingly. The packets submitted do not reference the correct "Climate Zone (North), "Permitting Office" (Palm Coast) and Jurisdiction Number (281400). b. The floor areas square footages listed do not match the floor plans. 11. On Roof Mechanical Plan (M7), exhaust fan/dryer vents penetrate through the roof while typical HVAC layout & structural roof framing plan (S-5) show wall penetrations. Please clarify. 12. On M3, clarify dryer vent equivalent length, 50 ft or 60 ft? Please add note to provide signs or stencils, which read, "Dryer shall be capable of venting through 60 equivalent ft." on wall close to dryer. 13. Equipment access through roof, 36x36 scuttle (A3.1C) does not show on structural roof framing plan (S-5). Provide structural section/detail and means of access. 14. On sanitary riser diagrams, show how vent system is connected from 1st floor to 4th floor to outside the building. 15. E5, clarify key note #5, is disconnect switch on heat pump D same for both DL/DT? 16. P9: a. One (1) bathroom group is missing on domestic water riser for Unit A. b. One (1) water closet & (1) lavatory are missing on water riser for Unit D. 17. P10: a. Sanitary risers S/2 & S/3 for Unit A are interchanged. b. Sanitary risers S/7 (WC-1) & S/3 should be S/5 & S/6 respectively. 18. P6 & P7: a. Clarify sanitary risers for Unit C. (All are S/5). b. Sanitary riser S/11 for Unit D is missing (P6 only). 19. A1.1S, A1.2S, A1.3S, A5.2 & A7.3: a. Stair tread and riser height shall meet code. 20. A2.1: a. Referenced 5/A4.2 does not match elevation (flipped windows). b. Referenced 6/A7.1 is missing. 21. A2.2 & A2.3, referenced section 6/A7.1 is missing. 22. A4.1, referenced detail 7/A7.1 is missing. 23. A7.5.1: a. Detail 7- Tenant Separation @ Top Floor on A i. Clarify referenced detail 2/A7.5 ii. Clarify referenced sheet A7.7 24. M1 to M7: a. Coordinate all Plan key notes references to match referenced details/sheets, delete or cross out them out if not applicable to the project. 25. Cover sheet: a. S-3 & S-4 drawing sheets title do not match with index of drawings. b. AS- 1 is in the package but not listed on index of drawings.
FI1 COMPLETE 08/29/2005 09/19/2005
Note: Released By: JPATTEE

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 01/08/2007
REINSPECTION FEE ¤40.00 01/08/2007
REINSPECTION FEE ¤40.00 01/08/2007
REVISION ¤40.00 01/08/2007
TTRANS IMPACT FEE CONDO/TOWN ¤40,768.00 12/28/2005
ADMIN FEE ¤20.00 12/28/2005
BUILDING CODE ADMIN FUND ¤289.16 12/28/2005
ELECTRIC FEE ¤2,463.60 12/28/2005
FIRE COMM IMPACT FEE 4-1-05 ¤27,805.63 12/28/2005
FIRE PLANS REVIEW ¤578.32 12/28/2005
MECHANICAL FEE ¤2,463.60 12/28/2005
PERMIT FEE ¤22,308.00 12/28/2005
PARKS IMPACT FEE 11-2-04 ¤31,385.48 12/28/2005
PLUMBING FEE ¤2,463.60 12/28/2005
RADON FEE ¤289.16 12/28/2005
Fees Total Due: ¤0.00 Total Paid: ¤130,994.55