I want to search for...

Permit #2005090066

Permit Details

Status: COED

Parcel Id: 07-11-31-7016-00120-0020
CONDITIONED SPACE: 2464 sqft
GARAGE: 616 sqft
OPENED PORCH (WITH ROOF) : 332 sqft
OPENED PORCH (WITH ROOF) : 90 sqft
Total Square Footage: 3502 sqft
Block: 0012
Subdivision: -
Job Phone: (386) 445-4515
Location Address: 3 CRISTON CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/19/2005
NOC: RECORDED
Applicant name: GREGORY LEE LE PERA
Owner: BONN ROGER A &

Address

JILL M H&W

SARTELL, MN 56377

Lot: 020
Contracted Stated Job Value: ¤118,272.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

WAYNE HOMES BY CENTEX
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

385 DOUGLAS AVE

ALTAMONTE SPRINGS, FL 32714

STE 3000

ALTAMONTE SPRINGS, FL 32714

CBC055301 (Exp: 09/30/2008) (386) 445-4515 (386)446-6285

Inspection History

Type Request Date Result Inspector
UTILITY COMPANY FINAL 03/30/2006 APPROVED RANDRADE
FINAL COMPLETE BUILDING INSPECTION 03/30/2006 FINAL APPROVED ARAYMOND
STORMWATER FINAL INSPECTION 03/28/2006 APPROVED BFCHAMBERLAIN
RESIDENTIAL EARLY POWER 03/16/2006 APPROVED - AS NOTED JMCGOWEN
Note: servise outlet missing bar wall, disconect missing on dishwasher
PRE DRIVEWAY 03/14/2006 APPROVED BFCHAMBERLAIN
LATH /BRICK FLASHING 02/20/2006 APPROVED ARAYMOND
INSULATION INSPECTION 02/10/2006 APPROVED JMCGOWEN
ALL ROUGH 02/07/2006 APPROVED JMCGOWEN
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 01/19/2006 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 01/17/2006 Disapproved -FEE REQUIRED ARAYMOND
Note: THIS IS A REINSPECTION previous notice 1 block gable end at garage, 2 block roof sheathing at garage gable end, block step trusses where sheathing span exeeds 24". x brace gable ends, missing valley straps, incomplete uplift for fg1
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 01/06/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: block and nail ends of o.s.b. running perpendiculare to trusses
LINTEL 12/20/2005 APPROVED JMCGOWEN
MONOLITHIC SLAB INSPECTION/SLAB 12/05/2005 APPROVED ARAYMOND
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB INSPECTION/SLAB 12/02/2005 Disapproved -FEE REQUIRED ARAYMOND
Note: THIS IS A REINSPECTION NO PLOT PLAN APPROVED LAYOUT PLAN ON SITE.
MONOLITHIC SLAB INSPECTION/SLAB 12/01/2005 Disapproved -FEE REQUIRED ARAYMOND
Note: NOT READY
FIRST ROUGH PLUMBING INSPECTION 11/28/2005 APPROVED - AS NOTED ARAYMOND
Note: NO WATER PRESSURE. CHECK AT SLAB.
RETAINING WALL 11/10/2005 APPROVED JMCGOWEN
STEM FOOTING FOUNDATION 10/27/2005 APPROVED JMCGOWEN
TEMPORARY POLE 09/29/2005 APPROVED ARAYMOND
Note: Libby - Susan - 4:00 - 9-29-05

Review History

Department Status Date In Date Out
BLD COMPLETE 09/13/2005 09/14/2005
Note: Released By: CCOTE Approved for Release per plan cover sheet.
ZON COMPLETE 09/13/2005 09/13/2005
Note: Released By: HHERKERT
DSD COMPLETE 09/02/2005 09/09/2005
Note: Released By: JCALVERT Sent to DSD for check of address - applicant states it should be # 3 - computer database indicate #2. Please update if required.
SWMD COMPLETE 09/02/2005 09/12/2005
Note: Released By: LAPTEKAR

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 03/30/2006
REINSPECTION FEE ¤40.00 03/30/2006
REINSPECTION FEE ¤40.00 03/30/2006
REINSPECTION FEE ¤40.00 03/30/2006
REINSPECTION FEE ¤40.00 03/30/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 09/19/2005
STORM WATER PERMIT FEES ¤80.00 09/19/2005
TRANSPORTATION IMPACT FEE3/RES ¤2,885.00 09/19/2005
ADMIN FEE ¤20.00 09/19/2005
ARC HOUSE REVIEW ¤125.00 09/19/2005
BUILDING CODE ADMIN FUND ¤17.51 09/19/2005
ELECTRIC FEE ¤148.80 09/19/2005
FIRE RES IMPACT FEE 4-1-05 ¤173.47 09/19/2005
MECHANICAL FEE ¤148.80 09/19/2005
PERMIT FEE ¤772.20 09/19/2005
PARKS IMPACT FEE 11-2-04 ¤1,120.91 09/19/2005
PLAN CHECK FEE ¤79.20 09/19/2005
PLUMBING FEE ¤148.80 09/19/2005
RADON FEE ¤17.51 09/19/2005
Fees Total Due: ¤0.00 Total Paid: ¤9,537.20