I want to search for...
Permit #2005090097
Permit Details
Status: COED
| Parcel Id: 07-11-31-7035-01230-0070 |
| CONDITIONED SPACE: 2312 sqft |
| GARAGE: 426 sqft |
| OPENED PORCH (WITH ROOF) : 158 sqft |
| OPENED PORCH (WITH ROOF) : 50 sqft |
| Total Square Footage: 2946 sqft |
| Block: 0123 |
| Subdivision: - |
| Job Phone: (386) 672-8285 |
| Location Address: 4 BIRDSEYE PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/21/2005 |
| NOC: RECORDED |
| Applicant name: JOSEPH TODD VANACORE |
| Owner: THEODORE & MARCIA WILK |
|
Address 1408 SUMMIT PLACE UNION, NJ 07083 |
| Lot: 070 |
| Contracted Stated Job Value: ¤189,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
VANACORE CONSTRUCTION INC.
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
1451 N US HIGHWAY 1 Ormond Beach, FL 32174 |
SUITE 13 Ormond Beach, FL 32174 |
CBC058991 (Exp: 08/31/2024) | (386) 672-8285 |
Sub Contractors
TRENT MIHALIC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P.O. BOX 606 ZELWOOD, FL 32798 |
EC0003150 (Exp: 08/31/2012) | (321) 229-1241 | (386)698-2956 |
DENNIS EDWARD CLARKE
| Status | Location Address | Mailing Address | State License Number | Phone |
| CANCEL |
200 TOMOKA AVE Ormond Beach, FL 32174 |
STE D Ormond Beach, FL 32174 |
CAC058147 (Exp: 09/30/2008) | (386) 671-1029 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
GREGORY A HAGEMAN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
545 Parque Drive Ormond Beach, FL 32174 |
CCC021394 (Exp: 08/31/2026) | (386) 672-2821 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 05/18/2006 | FINAL APPROVED | JLEVRAULT |
| STORMWATER FINAL INSPECTION | 05/16/2006 | APPROVED - AS NOTED | DSCHRAGER |
| Note: - 23 sqft of road damage. | |||
| UTILITY COMPANY FINAL | 05/15/2006 | APPROVED | RANDRADE |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 05/09/2006 | Disapproved - NO FEE | RANDRADE |
| Note: FAILED NO PEP PANEL NO PEP ELECTRIC PUMP | |||
| DRIVEWAY | 04/17/2006 | APPROVED | BFCHAMBERLAIN |
| Note: no box | |||
| RESIDENTIAL EARLY POWER | 04/06/2006 | APPROVED | JLEVRAULT |
| RESIDENTIAL EARLY POWER | 04/05/2006 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: EXPOSE GROUND RODS. | |||
| LATH /BRICK FLASHING | 02/16/2006 | APPROVED | MMOORE |
| INSULATION INSPECTION | 02/14/2006 | APPROVED | ARITTER |
| ALL ROUGH | 02/06/2006 | APPROVED | ARITTER |
| Note: Check plmb pressure at insulation | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/03/2006 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/27/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: THIS IS A REINSPECTION 1. ITEM #2 LAST NON-COMPLIANCE 2. ITEM # 5 SOME NOT GROUTED 3. PAGE 1/7 ON PLANS/ STRAPPING DETAIL (IN YELLOW) NOT PER PLAN | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/24/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: THIS IS A REINSPECTION 1. 2-PLY T-29 NAIL STUDS TOGETHER (ITEM#4 ) LAST NON-COMPLIANCE 2. END P.T. STUD GARAGE ON LEFT AT TOP DOUBLE TOP PLATE STRAP OVER THE TOP AND NAIL TO P.T. STUD EACH SIDE 3. OPEN EXTERIOR ENTRY BOX BEAMS FOR TAPCON INSPECTION /ITEM#8NLAST NON-COMPLIANCE 4. FIX BUCKET RIGHT SIDE GARAGE AT RED MARK 5. GROUT TRUSSES/ NOT FINISHED 6. 2-PLY TO4 AT DOUBLE BUCKET REMOVE BENT NAILS/ RENAIL | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/18/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. GROUT TRUSSES WITH STONELESS GROUT 2. AT A/C PLATFORM PAGE 1/7 HEADER STRAP LENGTH AND STUD PLATE TIE EACH SIDE OF A/C OPENING 3. OVER-FRAME/ GARAGE/ STRAPS NEED TO BE BLOCKED 4. HTT22/ WALL/TOP/ BOTTOM BOLTS MISSING AT THIS POINT/ NAIL 4 PACK OF STUDS TOGETHER 5. LEDGER/ LEFT GARAGE/ LAG TO STUDS 6. TRUSSES OVER SLIDER/ PACK-OUT STRAPS CENT -OVER 1/2", VAPOR BARRIER UNDER TRUSSES 7. 2-PLY T-29 NAIL TOGETHER PER TRUSS NOTES/ RIGHT-END HANGERS MISSING BOLTS/ NAIL TOGETHER 3 STUD PACK 8. TAPCON EXTERIOR ARCH AND SIDE BOX BEAMS 9. T-10 AT FIX, NAIL 2X4 NAIL PATTERN PER TRUSS FIX 10. ENTRY RIDGE FROM T-29 NOT BLOCKED ABOVE AT FRAME-OVER | |||
| TEMPORARY POLE | 01/18/2006 | APPROVED | MMOORE |
| LINTEL | 12/29/2005 | APPROVED | MMOORE |
| MONOLITHIC SLAB INSPECTION/SLAB | 12/19/2005 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 12/15/2005 | APPROVED | JLEVRAULT |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/22/2005 | 12/22/2005 |
| Note: Released By: LWOODROME Revision: Window buck attachment | |||
| BLD | COMPLETE | 09/12/2005 | 09/13/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | HOLD | 09/07/2005 | 09/07/2005 |
| Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. Provide a bond beam transition detail. 2. The floor plan references details A/5 & B/5 however these details could not be found on sheet 5. Please provide these details. | |||
| SWMD | COMPLETE | 09/06/2005 | 09/16/2005 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 09/06/2005 | 09/07/2005 |
| Note: Released By: BWRY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤284.00 | 05/19/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 05/19/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 05/19/2006 |
| REINSPECTION FEE | ¤40.00 | 05/19/2006 |
| REINSPECTION FEE | ¤40.00 | 05/19/2006 |
| REINSPECTION FEE | ¤40.00 | 05/19/2006 |
| REINSPECTION FEE | ¤40.00 | 05/19/2006 |
| REVISION | ¤40.00 | 05/19/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 10/21/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 10/21/2005 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 10/21/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 10/21/2005 |
| MECHANICAL FEE | ¤143.40 | 10/21/2005 |
| PERMIT FEE | ¤737.10 | 10/21/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 10/21/2005 |
| PLAN CHECK FEE | ¤75.60 | 10/21/2005 |
| PLUMBING FEE | ¤143.40 | 10/21/2005 |
| RADON FEE | ¤14.73 | 10/21/2005 |
| ADMIN FEE | ¤20.00 | 10/21/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 10/21/2005 |
| BUILDING CODE ADMIN FUND | ¤14.73 | 10/21/2005 |
| ELECTRIC FEE | ¤143.40 | 10/21/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,840.74 |