I want to search for...
Permit #2005090541
Permit Details
Status: COED
| Parcel Id: 07-11-31-7007-00490-0240 |
| CONDITIONED SPACE: 2038 sqft |
| GARAGE: 694 sqft |
| OPENED PORCH (WITH ROOF) : 402 sqft |
| OPENED PORCH (WITH ROOF) : 123 sqft |
| Total Square Footage: 3257 sqft |
| Block: 0049 |
| Subdivision: - |
| Job Phone: (386)447-4400 |
| Location Address: 20 FULTON PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/14/2005 |
| NOC: RECORDED |
| Applicant name: DAVID PAUL CROCKETT |
| Owner: PATRICK AND EMILY JAMES |
|
Address 3694 IVES COURT KENNESAW, GA 30152 |
| Lot: 240 |
| Contracted Stated Job Value: ¤199,990.00 |
| Job Description: SINGLE FAMILY HOME |
| Type: CN |
Contractor
THE WATERSIDE GROUP, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
17-B BRELYN PLACE PALM COAST, FL 32137 |
RG0041345 (Exp: 08/31/2010) | (386)447-4400 | (386)447-5800 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
LARRY MILTON HISS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1315 A LPGA BLVD Holly Hill, FL 32117 |
CAC032450 (Exp: 08/31/2018) | (386) 672-8688 | (386)238-8688 |
MARTIN JOHN EVANS
| Status | Location Address | State License Number |
| ACTIVE |
14 FORT CAROLINE CT BUNNELL, FL 32110 |
CFC057676 (Exp: 08/31/2026) |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 07/14/2006 | FINAL APPROVED | JGIBSON |
| STORMWATER FINAL INSPECTION | 07/12/2006 | APPROVED | BFCHAMBERLAIN |
| Note: THIS IS A REINSPECTION | |||
| STORMWATER FINAL INSPECTION | 07/05/2006 | Disapproved -FEE REQUIRED | BFCHAMBERLAIN |
| Note: Grade and place sod in left adj. swale. | |||
| UTILITY COMPANY FINAL | 06/27/2006 | APPROVED | TSCHWEERS |
| DRIVEWAY | 05/12/2006 | APPROVED | BFCHAMBERLAIN |
| INSULATION INSPECTION | 03/13/2006 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 03/10/2006 | APPROVED | ARAYMOND |
| INSULATION INSPECTION | 03/09/2006 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: THIS IS A REINSPECTION previous items 2,3, energy calcs must be approved | |||
| INSULATION INSPECTION | 03/07/2006 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: Not ready for inspection | |||
| ALL ROUGH | 02/20/2006 | APPROVED - AS NOTED | ARAYMOND |
| Note: FIRE STOP NEEDED AT BOXED AREA BEHIND DISPLAY AND KITCHEN DOOR. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/24/2006 | APPROVED | JMCGOWEN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/23/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: some straps not to plan and or missing | |||
| LINTEL | 12/22/2005 | APPROVED | JMCGOWEN |
| TEMPORARY POLE | 11/22/2005 | APPROVED | JMCGOWEN |
| Note: LIBBY - SUSAN - 4:00 / 11-22-05 | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 11/09/2005 | APPROVED | JMCGOWEN |
| FIRST ROUGH PLUMBING INSPECTION | 11/03/2005 | APPROVED | JMCGOWEN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/08/2006 | 03/09/2006 |
| Note: Released By: LWOODROME | |||
| BLD | COMPLETE | 01/05/2006 | 01/11/2006 |
| Note: Released By: LWOODROME Revision: Truss repair | |||
| BLD | COMPLETE | 10/12/2005 | 10/13/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | HOLD | 10/03/2005 | 10/05/2005 |
| Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. The foundation detail 5/3 shows a step at 16" wide. This does not appear to match the foundation plan at 8" wide. Revise plan or detail as required. 2. The lintel schedule has values that do not those contained in Cast-Crete literature. Please revise. 3. The lintel schedule provided appears to have an A, B, C, or D for each lintel type. There is no indication as to which one appears to each opening; such as L1A, L1B….. etc. 4. The lintel type descriptions do not match those used by Cast-Crete. Please revise to coordinate type designation used by Cast-Crete. 5. Provide information regarding down cell reinforcing type, size, required locations and maximum spacing. 6. Provide size of header to be used at openings in interior bearing wall. Include any connectors, straps, and/or fasteners to be used. 7. Indicate plywood wall sheathing to be used at gable end. Include thickness, grade, and fastening type size and spacing. 8. Indicate tapcon size and spacing to be used to secure wood framing to masonry at arch window over entry doors. 9. Provide framing detail for entry archway. Include framing size and attachment information. *A 'SAMPLE' Lintel Schedule is attached as an example of an acceptable lintel schedule. | |||
| SWMD | COMPLETE | 09/20/2005 | 09/23/2005 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 09/20/2005 | 10/03/2005 |
| Note: Released By: DCHAUDOIN |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 07/14/2006 |
| REINSPECTION FEE | ¤40.00 | 07/14/2006 |
| REINSPECTION FEE | ¤40.00 | 07/14/2006 |
| REVISION | ¤40.00 | 07/14/2006 |
| REVISION | ¤40.00 | 07/14/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 07/14/2006 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 10/14/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 10/14/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 10/14/2005 |
| ADMIN FEE | ¤20.00 | 10/14/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 10/14/2005 |
| BUILDING CODE ADMIN FUND | ¤16.29 | 10/14/2005 |
| ELECTRIC FEE | ¤150.00 | 10/14/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 10/14/2005 |
| MECHANICAL FEE | ¤150.00 | 10/14/2005 |
| PERMIT FEE | ¤780.00 | 10/14/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 10/14/2005 |
| PLAN CHECK FEE | ¤80.00 | 10/14/2005 |
| PLUMBING FEE | ¤150.00 | 10/14/2005 |
| RADON FEE | ¤16.29 | 10/14/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,581.96 |