I want to search for...

Permit #2005090649

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-00740-0010
CONDITIONED SPACE: 2256 sqft
GARAGE: 567 sqft
OPENED PORCH (WITH ROOF) : 327 sqft
OPENED PORCH (WITH ROOF) : 123 sqft
Total Square Footage: 3273 sqft
Block: 0074
Subdivision: -
Job Phone: (386)447-4400
Location Address: 130 LARAMIE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/04/2005
NOC: RECORDED
Applicant name: DAVID PAUL CROCKETT
Owner: GRONCZEWSKI ADAM E

Address

PATRICIA A GRONCZEWSKI

BRICK, NJ 08724

Lot: 010
Contracted Stated Job Value: ¤230,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

THE WATERSIDE GROUP, INC.
Status Location Address State License Number Phone Fax
CANCEL

17-B BRELYN PLACE

PALM COAST, FL 32137

RG0041345 (Exp: 08/31/2010) (386)447-4400 (386)447-5800

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 09/13/2006 FINAL APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 09/11/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. SEAL PLENUM AT PIPING 2. SEAL BACKWALL AT PLENUM AT BOTTOM 3. SEAL DUCT AT TOP OF UNIT (ELECTRIC/ REFRIGERANT), AT CEILING 4. SEAL WATER HEATER OUTLET ALSO LOW VOLTAGE AT CEILING 5. SEAL OVEN OUTLER 6. SEAL OUTLET/ EXTERIOR AT AQUALINK 7. 90 DEGREE ELBOW REQUIRED AT END OF CONDENSATE LINE POINTING DOWNWARD 8. CONDUIT BELOW METER ATTACH TO WALL 9. CONDUIT AT IRRIGATION CONTROL/ ATTACH TO WALL ALSO OUTSIDE CONDUIT
STORMWATER FINAL INSPECTION 09/05/2006 APPROVED DRANDALL
UTILITY COMPANY FINAL 08/31/2006 APPROVED TSCHWEERS
DRIVEWAY 05/31/2006 APPROVED - AS NOTED BFCHAMBERLAIN
Note: Replace silt fence by ditch
LATH /BRICK FLASHING 04/19/2006 APPROVED MMOORE
INSULATION INSPECTION 04/11/2006 APPROVED MMOORE
ALL ROUGH 04/07/2006 APPROVED MMOORE
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/05/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/04/2006 CANCELLED BY APPLICANT MMOORE
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/03/2006 CANCELLED BY APPLICANT MMOORE
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/30/2006 CANCELLED BY INSPECTOR MMOORE
Note: NOW THAT THE G IS OPEN AROUND THE COLUMNS REFER TO PAGE 1 0F 6 (IN YELLOW) 2. THERE APPEARS TO BE 2 LAYERS OF 2X4 WRAPPED AROUND COLUMN AND MORE THAN LIKELY THE INNER 2X4 IS PRESSURE TREATED AND TAPCONNED, . THIS IS HOW TO STABALIZE THE BOTTOM OF THE COLUMN FRAMING 3. ALL FRAMING INSIDE THE COLUMN BOXES TO BE P.T. OR HAVE A PIECE OF FELT PAPER IN BETWEEN NON P.T. AND CONCRETE
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/28/2006 Disapproved -FEE REQUIRED MMOORE
Note: THIS IS A REINSPECTION 1. over frame at windows not tapconned to concrete columns or concrete block ( 12" o.c.) 2. as per non-compliance item # 2 dated 3/23/06 not completed
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/23/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. ALL FRAMING OUTSIDE OF WINDOWS, AROUND ARCHES, COLUMNS TO BE TAPCONNED AT 12" O.C. INCLUDING PLYWOOD AGAINST CONCRETE BLOCK. 2. REMOVE FELT PAPER / APPLY TAPCONS AND LEAVE OPEN FOR INSPECTION
LINTEL 02/20/2006 APPROVED MMOORE
LINTEL 02/17/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. BACK WALLS WITH 4" OF BLOCK ON TOP OF LINTEL HEADERS DO NOT HAVE REBAR RUNNING THROUGH 2. NEED CHANGE/ REVISION
MONOLITHIC SLAB INSPECTION/SLAB 01/06/2006 APPROVED MMOORE
MONOLITHIC SLAB INSPECTION/SLAB 01/05/2006 Disapproved -FEE REQUIRED MMOORE
Note: SLEEVE 4 COPPER LINES AT M.BATH AT REBAR, 2 AT LAUNDRY AREA
FIRST ROUGH PLUMBING INSPECTION 12/30/2005 APPROVED JMCGOWEN
Note: THIS IS A REINSPECTION
FIRST ROUGH PLUMBING INSPECTION 12/27/2005 Disapproved -FEE REQUIRED JLEVRAULT
Note: Not ready
FIRST ROUGH PLUMBING INSPECTION 12/22/2005 CANCELLED BY INSPECTOR JMCGOWEN
TEMPORARY POLE 12/12/2005 APPROVED JLEVRAULT

Review History

Department Status Date In Date Out
BLD COMPLETE 03/16/2006 03/20/2006
Note: Released By: LWOODROME Revision: Truss bearing points and truss profiles
ZON COMPLETE 02/10/2006 02/14/2006
Note: Released By: HHERKERT
BLD COMPLETE 11/01/2005 11/01/2005
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R>
URB COMPLETE 10/20/2005 10/20/2005
Note: Released By: CGOEWEY
BLD HOLD 10/03/2005 10/10/2005
Note: Held By: FREODICA 1. Provide lintel schedule showing specific type for each window/door, garage door & covered porch openings. 2. Provide spacing of downcells and its maximum limit. 3. Revise foundation plan or detail 5/3 to match dimensions (step section ). 4. Indicate thickness, grade & fastener type size and spacing of wall sheating shown in detail 11/6 (gable end section) 5. Indicate tapcon size and spacing to be used to secure wood framing to masonry at arch window over entry doors. 6. Provide framing detail for entry archway. Indicate framing size and attachment information.
SWMD COMPLETE 09/22/2005 09/23/2005
Note: Released By: LAPTEKAR
ZON HOLD 09/22/2005 10/03/2005
Note: Held By: HHERKERT need correct landscape plan, landscape plan submitted has front entry garage, house placement on site plan has side entry garage
ZON COMPLETE 11/01/2005
Note: Released By: HHERKERT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 09/14/2006
REINSPECTION FEE ¤40.00 09/14/2006
REINSPECTION FEE ¤40.00 09/14/2006
REINSPECTION FEE ¤40.00 09/14/2006
REINSPECTION FEE ¤40.00 09/14/2006
REINSPECTION FEE ¤40.00 09/14/2006
REVISION ¤40.00 09/14/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 11/04/2005
STORM WATER PERMIT FEES ¤80.00 11/04/2005
TRANSPORTATION IMPACT FEE3/RES ¤2,885.00 11/04/2005
ADMIN FEE ¤20.00 11/04/2005
ARC HOUSE REVIEW ¤125.00 11/04/2005
BUILDING CODE ADMIN FUND ¤16.37 11/04/2005
ELECTRIC FEE ¤168.00 11/04/2005
FIRE RES IMPACT FEE 4-1-05 ¤173.47 11/04/2005
MECHANICAL FEE ¤168.00 11/04/2005
PERMIT FEE ¤897.00 11/04/2005
PARKS IMPACT FEE 11-2-04 ¤1,120.91 11/04/2005
PLAN CHECK FEE ¤92.00 11/04/2005
PLUMBING FEE ¤168.00 11/04/2005
RADON FEE ¤16.37 11/04/2005
Fees Total Due: ¤0.00 Total Paid: ¤9,810.12