| Parcel Id: 07-11-31-7035-00090-0340 |
| CONDITIONED SPACE: 2105 sqft |
| GARAGE: 413 sqft |
| OPENED PORCH (WITH ROOF) : 349 sqft |
| OPENED PORCH (WITH ROOF) : 62 sqft |
| Total Square Footage: 2929 sqft |
| Block: 0009 |
| Subdivision: - |
| Job Phone: (386) 586-1109 |
| Location Address: 25 BURNING SANDS LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/05/2005 |
| NOC: RECORDED |
| Applicant name: GREGORY THOMAS BEATY |
| Owner: AFFORDABLE FLORIDA HOMES |
| Lot: 340 |
| Contracted Stated Job Value: ¤165,449.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
| Type |
Request Date |
Result |
Inspector |
|
FINAL COMPLETE BUILDING INSPECTION |
04/26/2006 |
FINAL APPROVED |
JLEVRAULT |
|
UTILITY COMPANY FINAL |
04/17/2006 |
APPROVED |
RANDRADE |
|
STORMWATER FINAL INSPECTION |
04/11/2006 |
APPROVED |
BFCHAMBERLAIN |
|
DRIVEWAY |
03/14/2006 |
APPROVED |
BFCHAMBERLAIN |
|
LATH /BRICK FLASHING |
02/13/2006 |
APPROVED |
JLEVRAULT |
|
Note: THIS IS A REINSPECTION
|
|
LATH /BRICK FLASHING |
02/10/2006 |
CANCELLED BY APPLICANT |
LMUSGROVE |
|
INSULATION INSPECTION |
02/09/2006 |
APPROVED |
ARAYMOND |
|
ALL ROUGH |
02/01/2006 |
APPROVED |
ARITTER |
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
01/30/2006 |
APPROVED - AS NOTED |
JLEVRAULT |
|
Note: THIS IS A REINSPECTION NO DETAIL FOR T-17 TO T - 05 CONNECTION. PROVIDE BY ALL ROUGH.
|
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
01/27/2006 |
CANCELLED BY APPLICANT |
MMOORE |
|
Note: THIS IS A REINSPECTION
|
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
01/26/2006 |
CANCELLED BY APPLICANT |
MMOORE |
|
Note: THIS IS A REINSPECTION
|
|
ROOF SHEATHING/BRACES/TIES/ DOWN CELL |
01/24/2006 |
Disapproved -FEE REQUIRED |
JLEVRAULT |
|
Note: Roof plan is reversed. Missing strap at rear porch. Front porch boxouts not done - leave hole is osb for inspection.
|
|
LINTEL |
12/22/2005 |
APPROVED |
MMOORE |
|
MONOLITHIC SLAB INSPECTION/SLAB |
12/14/2005 |
APPROVED |
MMOORE |
|
Note: 1) Footer in places is lacking 3" of clearance under bottom vertical steel. 2) Misc. dowels are sitting in mud. 3) Clean mud from rebar where needed. 4) Lacking 3" clearance left side of garage due to cave-ins.
|
|
MONOLITHIC SLAB INSPECTION/SLAB |
12/13/2005 |
Disapproved -FEE REQUIRED |
MMOORE |
|
MONOLITHIC SLAB INSPECTION/SLAB |
12/12/2005 |
Disapproved -FEE REQUIRED |
ARITTER |
|
Note: 1. NO DETAIL DRAWING SHOWING SIZE OF REINFORCING STEEL FOR PIER FOOTINGS IN FRONT.
2.ENTRY FOOTING AT FRONT ARE FLOODED.
3. CLEAN OUT WASHED OUT AREA AT BACK.
|
|
FIRST ROUGH PLUMBING INSPECTION |
12/06/2005 |
APPROVED |
JLEVRAULT |
|
Note: THIS IS A REINSPECTION
|
|
FIRST ROUGH PLUMBING INSPECTION |
12/05/2005 |
CANCELLED BY APPLICANT |
JLEVRAULT |