I want to search for...
Permit #2005090871
Permit Details
Status: COED
| Parcel Id: 07-11-31-7028-00700-0080 |
| CONDITIONED SPACE: 2154 sqft |
| GARAGE: 442 sqft |
| OPENED PORCH (WITH ROOF) : 162 sqft |
| OPENED PORCH (WITH ROOF) : 62 sqft |
| PATIO/DECK (NO ROOF) : 154 sqft |
| Total Square Footage: 2974 sqft |
| Block: 0070 |
| Subdivision: - |
| Job Phone: (386)437-5782 |
| Location Address: 1 POINCE PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/31/2006 |
| NOC: RECORDED |
| Applicant name: SANDRA LEE FRENCH |
| Owner: LEATHAN, MICHELLE & MICHAEL J. WEIDL |
|
Address 55 POINT OF WOODS DRIVE PALM COAST, FL 32164 |
| Lot: 080 |
| Contracted Stated Job Value: ¤150,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SANDEX HOMES
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
27 EGAN DR PALM COAST, FL |
CRC1327302 (Exp: 09/30/2008) | (386)437-5782 | (386)437-5782 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 10/17/2006 | FINAL APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| STORMWATER FINAL INSPECTION | 10/16/2006 | CANCELLED BY APPLICANT | KJOHNSON |
| Note: road damage inspection only. Sandra french called back to cancel. | |||
| FINAL COMPLETE BUILDING INSPECTION | 10/13/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: NEED TO HAVE ALL SWITCHES IN MASTER BEDROOM ON ARC FAULT BREAKERS. NEED TO HAVE SHADE TREES AND UNDERSTORY TREES. | |||
| STORMWATER FINAL INSPECTION | 10/11/2006 | APPROVED - AS NOTED | GLALIMA |
| Note: 24 ' FEET OF ROAD DAMAGE = 292. 00 / SEE LAST REPORT . IF THE BUILDER DID NOT LIKE THE 24' FEET OF ROAD DAMAGE , THEN THE NEXT TIME BEFOR HOUSE , START ON A CORNER LOT THEY SHOULD HAVE A PRE, ROAD INSPICTION . THANK YOU GARY LALIMA . | |||
| STORMWATER FINAL INSPECTION | 10/11/2006 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: SWEEP ALL OF ROAD SO I CAN ASSESS ALL OF ROAD AND BE FAIR . RUN SPRINKLER 2 HOURS BEFOR NEXT INSPECTION AND HAVE WATER RUNNING . | |||
| RESIDENTIAL EARLY POWER | 10/06/2006 | APPROVED | ACOOPER |
| UTILITY COMPANY FINAL | 10/04/2006 | APPROVED | MBACON |
| DRIVEWAY | 09/11/2006 | APPROVED | DRANDALL |
| LATH /BRICK FLASHING | 07/07/2006 | APPROVED | RMARVEL |
| INSULATION INSPECTION | 06/26/2006 | APPROVED | ARITTER |
| ALL ROUGH | 06/21/2006 | APPROVED | ARITTER |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 06/19/2006 | Disapproved -FEE REQUIRED | ARITTER |
| Note: ventfan ducts incomplete, need to locate switch for garden tub | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/05/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/03/2006 | Disapproved -FEE REQUIRED | ARITTER |
| Note: X brace gables per details d-3. block back ridges. block step trusses that exceed 24in. on center. | |||
| LINTEL | 03/21/2006 | APPROVED | TOUTLAND |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 03/20/2006 | Disapproved -FEE REQUIRED | TOUTLAND |
| Note: THIS IS A REINSPECTION cut out lintel block at vent stacks | |||
| LINTEL | 02/22/2006 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: Placement of lintel steel is (presently lying on the bottom). See D3 details A,B,C. | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 02/08/2006 | APPROVED | ARAYMOND |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 02/03/2006 | CANCELLED BY APPLICANT | TOUTLAND |
| FIRST ROUGH PLUMBING INSPECTION | 02/01/2006 | APPROVED | ARAYMOND |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/26/2006 | 04/27/2006 |
| Note: Released By: LWOODROME Revision: Truss repair | |||
| BLD | COMPLETE | 03/14/2006 | 03/17/2006 |
| Note: Released By: CCOTE Approved for Release. | |||
| BLD | COMPLETE | 12/20/2005 | 12/22/2005 |
| Note: Released By: LWOODROME Revision: Truss connector schedule | |||
| BLD | COMPLETE | 10/19/2005 | 10/19/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R> | |||
| URB | COMPLETE | 10/14/2005 | 10/19/2005 |
| Note: Released By: CGOEWEY | |||
| ZON | HOLD | 10/07/2005 | 10/12/2005 |
| Note: Held By: HHERKERT does not meet front/side setback of 25'. | |||
| ZON | HOLD | 09/29/2005 | 10/07/2005 |
| Note: Held By: BWRY NEED TO SHOW WHAT TREES ARE GEING SAVED AND WHICH ONES ARE NOT. MUST HAVE 4 TREES SHOWN ON LOT. ALSO NEED FOUNDATION PLANTING ON POINT OF WOODS DRIVE SIDE OF HOUSE. | |||
| SW1 | COMPLETE | 09/29/2005 | 10/03/2005 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 10/14/2005 | |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 10/18/2006 |
| REINSPECTION FEE | ¤40.00 | 10/18/2006 |
| REINSPECTION FEE | ¤40.00 | 10/18/2006 |
| REINSPECTION FEE | ¤40.00 | 10/18/2006 |
| REINSPECTION FEE | ¤40.00 | 10/18/2006 |
| REINSPECTION FEE | ¤40.00 | 10/18/2006 |
| REVISION | ¤40.00 | 10/18/2006 |
| REVISION | ¤40.00 | 10/18/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 10/18/2006 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 01/31/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 01/31/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/31/2006 |
| REVISION | ¤40.00 | 01/31/2006 |
| ADMIN FEE | ¤20.00 | 01/31/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 01/31/2006 |
| BUILDING CODE ADMIN FUND | ¤14.87 | 01/31/2006 |
| ELECTRIC FEE | ¤132.00 | 01/31/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 01/31/2006 |
| MECHANICAL FEE | ¤132.00 | 01/31/2006 |
| PERMIT FEE | ¤663.00 | 01/31/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 01/31/2006 |
| PLAN CHECK FEE | ¤68.00 | 01/31/2006 |
| PLUMBING FEE | ¤132.00 | 01/31/2006 |
| RADON FEE | ¤14.87 | 01/31/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,556.12 |