I want to search for...
Permit #2005090946
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-00590-0040 |
| GARAGE: 492 sqft |
| OPENED PORCH (WITH ROOF) : 265 sqft |
| OPENED PORCH (WITH ROOF) : 51 sqft |
| CONDITIONED SPACE: 1864 sqft |
| Total Square Footage: 2672 sqft |
| Block: 0059 |
| Subdivision: - |
| Job Phone: (386) 445-2222 |
| Location Address: 16 ELLISON LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/01/2005 |
| NOC: RECORDED |
| Applicant name: MICHAEL STEPHAN MULLEN |
| Owner: ROLAND & LINDA GLEASON |
|
Address 1 ENTERPRISE DR PALM COAST, FL 32137 |
| Lot: 040 |
| Contracted Stated Job Value: ¤110,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
TOWN & COUNTRY HOMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1 Enterprise Drive Bunnell, FL 32110 |
CGC049972 (Exp: 08/31/2026) | (386) 445-2222 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 09/08/2006 | FINAL APPROVED | KSAMPICO |
| RESIDENTIAL EARLY POWER | 08/29/2006 | APPROVED | KSAMPICO |
| RESIDENTIAL EARLY POWER | 08/28/2006 | CANCELLED BY APPLICANT | AIRS WEB |
| UTILITY COMPANY FINAL | 08/28/2006 | APPROVED | TREESE |
| Note: THIS IS A REINSPECTION | |||
| STORMWATER FINAL INSPECTION | 08/23/2006 | APPROVED - AS NOTED | GLALIMA |
| Note: 28' FEET ROAD DAMAGE = 324.00 SOD SWALE AFTER REMOVCE TOILET WILL DO RIDE BY. | |||
| RESIDENTIAL EARLY POWER | 08/23/2006 | CANCELLED BY APPLICANT | AIRS WEB |
| UTILITY COMPANY FINAL | 08/21/2006 | Disapproved - NO FEE | MBACON |
| Note: FAILED NO STUB OUT FOR PEP PANEL ELECTRICAL WIRE NEEDS PEP PANEL CONDUIT AND WIRES ALSO NEEDS PUMP AND ASSEMBLY | |||
| PRE DRIVEWAY | 07/20/2006 | CANCELLED BY INSPECTOR | LAPTEKAR |
| Note: already passed 2nd inspection 7/19 | |||
| DRIVEWAY | 07/18/2006 | APPROVED - AS NOTED | GLALIMA |
| Note: SAME DAY INSPECTION / FAILED TO PASSED , READY TO POUR . | |||
| PRE DRIVEWAY | 07/18/2006 | Disapproved -FEE REQUIRED | GLALIMA |
| INSULATION INSPECTION | 06/09/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 06/07/2006 | APPROVED | JGIBSON |
| INSULATION INSPECTION | 06/06/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Fire block @ kit. vent & master vent stack. | |||
| ALL ROUGH | 06/01/2006 | APPROVED | JGIBSON |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/10/2006 | APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/03/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: All 2--ply & 3 --ply trusses not nailed per engineering detail, OK to shingle roof must call for reinspection. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/20/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION.IMPROPER STRAPS ON LOAD BEARING WALL,NOT TO PLAN(SP1,SP2s) TRUSS ENGINEERING PACK NOT ON SITE. | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 04/20/2006 | Disapproved - NO FEE | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/18/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Tap-cons needed @ entry by columns @ CMU, exterior wall not anchord, @ master bed-room, exterior wall not anchord by guest bath and @ floor, improper straps on load bearing wall not per plan, incomplete list no truss engineering. | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 04/18/2006 | Disapproved - NO FEE | JGIBSON |
| LINTEL | 02/17/2006 | APPROVED | DROCKWELL |
| TEMPORARY POLE | 02/16/2006 | APPROVED | JGIBSON |
| Note: CALL FPL AT 4:45 SUSAN | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 01/25/2006 | APPROVED | JGIBSON |
| FIRST ROUGH PLUMBING INSPECTION | 01/19/2006 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/27/2006 | 05/01/2006 |
| Note: Released By: CCOTE Approved for Release. Revision: Change Sp1&2 to SP4. | |||
| BLD | COMPLETE | 10/25/2005 | 10/25/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| SW1 | COMPLETE | 10/10/2005 | 10/10/2005 |
| Note: Released By: WKINELL Builder came in and signed app. | |||
| BLD | HOLD | 10/07/2005 | 10/17/2005 |
| Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. Provide information for framing of exterior wood stud wall between house and covered porch. Indicate framing size, spacing, attachment to slab and etc. 2. Provide a mitered glass wall section. | |||
| SW1 | COMPLETE | 09/30/2005 | 10/10/2005 |
| Note: Released By: WKINELL Held By: WKINELL ROW permit application missing signature and date.\\wk | |||
| ZON | COMPLETE | 09/30/2005 | 10/07/2005 |
| Note: Released By: BWRY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤324.00 | 09/11/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 09/11/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 09/11/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 09/11/2006 |
| REINSPECTION FEE | ¤40.00 | 09/11/2006 |
| REINSPECTION FEE | ¤40.00 | 09/11/2006 |
| REINSPECTION FEE | ¤40.00 | 09/11/2006 |
| REINSPECTION FEE | ¤40.00 | 09/11/2006 |
| REVISION | ¤40.00 | 09/11/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 09/11/2006 |
| TRANSPORTATION IMPACT FEE3/RES | ¤2,885.00 | 11/01/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 11/01/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 11/01/2005 |
| ADMIN FEE | ¤20.00 | 11/01/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 11/01/2005 |
| BUILDING CODE ADMIN FUND | ¤13.36 | 11/01/2005 |
| ELECTRIC FEE | ¤120.60 | 11/01/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 11/01/2005 |
| MECHANICAL FEE | ¤120.60 | 11/01/2005 |
| PERMIT FEE | ¤588.90 | 11/01/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 11/01/2005 |
| PLAN CHECK FEE | ¤60.40 | 11/01/2005 |
| PLUMBING FEE | ¤120.60 | 11/01/2005 |
| RADON FEE | ¤13.36 | 11/01/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,721.20 |